Description
hardware flow control. It is an ideal choice in the field of industrial automation.
user experience
Secondly, if power system engineers are to consider the convenience and speed of using the product in the future, operability needs to be improved while ensuring stability.
This requires a simple self-service system and an operation interface with good visual effects that can meet the needs of users. Some operating habits and other aspects
* cut costs
Furthermore, since there are many nodes in the power system, the same product needs to be deployed on many nodes. Then when the quantity of required products increases,
cost issues will inevitably be involved. How to solve the research and development, construction and installation of products and better reduce operating expenses is also a major issue that ABB needs to consider.
Implementation of communication between Omron vision system and ABB industrial robot
introduction
In modern production processes, vision systems are often used to measure and identify products, and then the results are transmitted to industrial robots for work
through communications . In this process, communication settings are very important. This article analyzes the communication implementation process between the Omron
FH-L550 vision system and ABB industrial robots. The main task is to enable the vision system to provide data detection results for ABB industrial robots, and the industrial robots
perform related operations based on the data results. This article mainly discusses the entire process of visual system communication transmission implementation.
1Ethernet-based communication settings in vision software
The main communication methods of Omron FH-L550 vision system controller are as follows [2], namely: parallel communication, PLCLINK communication, Ethernet
communication, EtherCAT communication, and protocol-free communication. These five communication methods have their own characteristics in the communication process.
In modern equipment, Ethernet communication
(Ethernet communication) is the most common, so this article uses the Ethernet communication method as an example to analyze and explain.
First, select the “Tools” option in the main interface, select the “System Settings” menu (Figure 1), after entering the “System Settings” menu, click the “Startup Settings” option,
and select the “Communication Module” tab (Figure 2 ), after completing the above settings, return to the main interface to save the settings (Figure 3). Finally, select the function
menu to perform system restart settings, and wait for the system to complete the restart before proceeding to the next step.
After the system restarts, click the “System Settings” menu again and select the “Ethernet (No Protocol (UDP))” option (Figure 4). In this option, there will be parameter settings
such as IP address and port. What needs to be noted here are the two IP address parameters. The parameters in “Address Setting 2” need to be filled in. The information that needs
to be filled in includes the IP address of the vision controller, subnet mask, default gateway and DNS server.
In the port number setting of “Input/Output Settings” at the bottom of the menu, set the port number for data input with the sensor controller. Note that the port number should
be the same as the host side, and finally complete the settings and corresponding data saving work.
2ABB industrial robot communication settings
First, configure the WAN port IP address for the ABB industrial robot. Select the control panel in the teach pendant, then select configuration, then select communication in
the theme, click IPSetting, set the IP information and click “Change” to save the IP information.
Next, use the SocketCreate robot command to create a new socket using the streaming protocol TCP/IP and assign it to the corresponding variable (Figure 5). Then
use the SocketConnect command to connect the socket to the remote computer. After the communication connection is completed, it is necessary to send and receive
information from the visual system. To send information, use the SocketSend instruction to send data instructions to the remote computer. After the vision system collects
information and makes judgments, the industrial robot system will receive data from the remote computer. The data reception is completed using the
SocketReceive instruction. This instruction stores the data in the corresponding string variable while receiving the data. Useful information needs to be extracted from the
received data information, which requires StrPart to find the specified character position instruction, extract the data at the specified position from the string, and assign the
result to a new string variable. Finally, when the socket connection is not in use, use SocketCloSe to close it.
https://www.xmamazon.com
https://www.xmamazon.com
https://www.plcdcs.com/
www.module-plc.com/
https://www.ymgk.com
ACSM1-04AM-016A-4 Mechanical drive module
1756-CNBR/E Communication interface module
3HAC025338-004/06D main servo drive unit
1747-L552/C SLC 500 processor
3HAC7998-2 Cable
IS200ERRRH1A Redundant relay for exciter regulator
2711P-T10C15D1 Operator terminal
2711P-T10C15D1 Operator terminal
2711P-T10C15A1 Operator terminal
2711P-T7C15D1 Touch screen
UFC719AE101 3BHB003041R0101 Controller module
UGTMEM-03LBB11 22.5V servo motor
20BD8P0A3AYNAND0 Digital PWM AC driver
6FC5203-0AF02-0AA1 Siemens Operating panel
HE693SNP306AX Cable connector
QTERM-K65 Beijer panel installation man-machine interface
2711PC-T6C20D8 PanelView Plus 6 Compact 600 Graphics terminal
CIMREX60 BEIJER Operator Panel
NTCF23 Optical fiber communication terminal
F3322 Digital output module
F7133 4-channel power distribution module
6181P-15TP2KH integrated display computer
IS220PSVOH1A servo control package
8440-1715 SPM-D11 synchronizer WOODWARD
FC-TSAI-1620M Security manager system module
TSXP57204M SCHNEIDER Processeur TSX 57
IMDSO04 Digital slave output module
P0926JM FOXBORO Secondary power input
330851-02-000-060-10-00-00 Expansion sensor
330850-50-00 BENTLY NEVADA preprocessor
330854-040-24-00 Differential extension cable
1746-NIO4V Analog Input
1785-V40L Programmable controller
TRICONEX 3720 Communication Module 3721 3721C
PFTL101B 2.0KN 3BSE004185R1 Tension sensor
DS200SIOBH1ACA circuit board module
UTV-F2500HA Manipulator controller
6DD1661-0AB1 Communication component
Reviews
There are no reviews yet.