Nine Questions and Answers on Common Faults in ABB Industrial Robot Applications
Question 1: Under what circumstances do I need to back up my robot?
Answer: 1. After the new machine is powered on for the first time.
2. Before making any modifications.
3. After completing the modification.
4. If the robot is important, conduct it regularly once a week.
5. It is best to make a backup on a USB flash drive.
6. Delete old backups regularly to free up hard drive space.
Second question: What does the alarm message 10106 maintenance time reminder mean when the robot appears?
Answer: This is the intelligent periodic maintenance reminder of ABB robots.
Question 3: What should I do if the robot enters a system failure state when it is powered on?
Answer: 1. Restart the robot.
2. If it doesn”t work, check whether there is a more detailed alarm prompt on the teaching pendant and handle it.
3. Restart.
4. If it still cannot be lifted, try B startup.
5. If it still doesn’t work, try P startup.
6. If it still doesn’t work, try I startup (this will return the robot to factory settings, be careful).
Question 4: Can robot backup be shared by multiple robots?
Answer: No, for example, the backup of robot A can only be used for robot A, not robots B or C, because this will cause system failure.
Five questions: What files can be shared in the robot backup?
Answer: If the two robots are of the same model and configuration. You can share RAPID programs and EIO files, but they must be verified before they can be used normally.
Question 6: What is the mechanical origin of the robot? Where is the mechanical origin?
Answer: The six servo motors of the robot have a unique fixed mechanical origin. Incorrectly setting the mechanical origin of the robot will cause problems such
as limited movement or malfunction of the robot, the inability to walk in a straight line, etc., and serious damage to the robot.
Question 7: How to cancel the robot 50204 motion monitoring alarm?
Answer: 1. Modify the robot action monitoring parameters (control panel – action monitoring menu) to match the actual situation.
2. Use the AccSet command to reduce the robot”s acceleration.
3. Reduce the v_rot option in the speed data.
Eight questions: What should I do if the robot alarms “50296, SMB memory data difference” when it is powered on for the first time?
Answer: 1. Select calibration in the ABB main menu.
2. Click ROB_1 to enter the calibration screen and select SMB memory.
3. Select “Advanced” and click “Clear Control Cabinet Memory” after entering.
4. Click “Close” when finished, then click “Update”.
5. Select “The control cabinet or robot has been exchanged, and the control cabinet is updated using SMB memory data.”
Question 9: How to customize the speed of robot trajectory in the RAPID program?
Answer: 1. Select program data in the main menu of the teaching pendant.
2. After finding the data type Speeddata, click New.
3. Click on the initial value. The meanings of the four variables of Speeddata are: v_tcp represents the linear operating speed of the robot, v_rot
represents the rotational operating speed of the robot, v_leax represents the linear operating speed of the additional axis, v_reax represents the rotational
operating speed of the additional axis, if there is no additional axis, then No need to modify the two.
4. The customized data can be called in the RAPID program.
https://www.xmamazon.com
https://www.xmamazon.com
https://www.plcdcs.com/
www.module-plc.com/
https://www.ymgk.com
Phoenix PATG1/23 1013847 Conductor marker carrier
Vibro-meter 200-560-000-113 200-560-101-017 VM600 IOC4T
IGCT 5SHY4045L0006 3BHB030310R0001 3BHE039203R0101 GVC736CE101 ABB
444-680-000-511 Vibro-Meter CE 680 M511 all-purpose vibration sensor
PFEA111-65/3BSE050090R65 ABB Tension Electronics PFEA 111
TRICON 4201 RXM Communication Module (Remote)
ENTERASYS A2H254-16 P0973BK Industrial switch
810-068158-013 LAM Print edition
TRICON 9001NJ(6FEET) FOXBORO Rack connection wire
125840-01 Half-Height Module 3500/15
TRICONEX 8105N Empty channel module panel
200-510-070-113 200-510-111-034 VM600 MPC4
130944-01 BLANK MODULE 3055/05
JOHNSON MS-NAE4510-2 controls MS-NAE5510-3 MS-NAE5510-1
VMIVME-7610-734 VME Single Board Computer
125680-01 Proximitor I/O Module Bently Nevada 3500/40M
125388-01 Half-height Module Bently Nevada
170AAO92100 Analog output module
SCHNEIDER VX5G48C32Q Power drive board
E82ZAFCC010 LENZE CAN INTERFACE MODULE
PNI800 Plant Network Interface Module
3500/05-01-02-00-00-01 System Rack 3500/05
IS215VCMIH2BB IS200VCMIH2BCC
FX3G-40MT/ESS Mitsubishi PLC main unit
PXIE-8115 NI PXI controller
PXIE-1065 NI PXIE case PXIE-6556
PIO800K02 ABB Profibus I/O Interface Kit [Redundant]
PNI800 Plant Network Interface Module
AI04 ABB AI module, 16-CH, TC / mV AI03
AI03 ABB AI module AI04
9907-014 Load distribution and speed control
IC755CSS15CDA Operator interface terminal
2711-T5A2L1 PanelView 550 Standard Operator terminal
VMIVME2540-000 intelligent digital input/output board
IC755SUE10CTD Touch screen GE
A06B-6110-H030 servo power converter
MDX61B0075-5A3-4-0T SEW drive
DS200LDCCH1AMA driver controls LAN(local Area Network) communication board
Pxi-8431/8 PXI Serial interface module
PXIE-6368 Multifunctional input/output module
Pxi-6528 PXI Digital input/output module
1769-L18ER-BB1B Programmable Automation controller
VMIVME-7751 VME single-board computer VMIVME-7750
1794-IRT8XT thermocouple RTD millivolt input module
PCI-1424 digital camera image acquisition board
IC220PBI002 Versapoint communication module
A06B-6079-H105 servo module
A06B-6117-H105 servo amplifier
A02B-0319-B500 Control basic unit
1326AS-B460F-21 servo motor
A06B-6140-H011 servo power converter
DSQC652 3HAC025917-001 Robot controller
DSQC604 3HAC12928-1 Power module
Reviews
There are no reviews yet.