Nine Questions and Answers on Common Faults in ABB Industrial Robot Applications
Question 1: Under what circumstances do I need to back up my robot?
Answer: 1. After the new machine is powered on for the first time.
2. Before making any modifications.
3. After completing the modification.
4. If the robot is important, conduct it regularly once a week.
5. It is best to make a backup on a USB flash drive.
6. Delete old backups regularly to free up hard drive space.
Second question: What does the alarm message 10106 maintenance time reminder mean when the robot appears?
Answer: This is the intelligent periodic maintenance reminder of ABB robots.
Question 3: What should I do if the robot enters a system failure state when it is powered on?
Answer: 1. Restart the robot.
2. If it doesn”t work, check whether there is a more detailed alarm prompt on the teaching pendant and handle it.
3. Restart.
4. If it still cannot be lifted, try B startup.
5. If it still doesn’t work, try P startup.
6. If it still doesn’t work, try I startup (this will return the robot to factory settings, be careful).
Question 4: Can robot backup be shared by multiple robots?
Answer: No, for example, the backup of robot A can only be used for robot A, not robots B or C, because this will cause system failure.
Five questions: What files can be shared in the robot backup?
Answer: If the two robots are of the same model and configuration. You can share RAPID programs and EIO files, but they must be verified before they can be used normally.
Question 6: What is the mechanical origin of the robot? Where is the mechanical origin?
Answer: The six servo motors of the robot have a unique fixed mechanical origin. Incorrectly setting the mechanical origin of the robot will cause problems such
as limited movement or malfunction of the robot, the inability to walk in a straight line, etc., and serious damage to the robot.
Question 7: How to cancel the robot 50204 motion monitoring alarm?
Answer: 1. Modify the robot action monitoring parameters (control panel – action monitoring menu) to match the actual situation.
2. Use the AccSet command to reduce the robot”s acceleration.
3. Reduce the v_rot option in the speed data.
Eight questions: What should I do if the robot alarms “50296, SMB memory data difference” when it is powered on for the first time?
Answer: 1. Select calibration in the ABB main menu.
2. Click ROB_1 to enter the calibration screen and select SMB memory.
3. Select “Advanced” and click “Clear Control Cabinet Memory” after entering.
4. Click “Close” when finished, then click “Update”.
5. Select “The control cabinet or robot has been exchanged, and the control cabinet is updated using SMB memory data.”
Question 9: How to customize the speed of robot trajectory in the RAPID program?
Answer: 1. Select program data in the main menu of the teaching pendant.
2. After finding the data type Speeddata, click New.
3. Click on the initial value. The meanings of the four variables of Speeddata are: v_tcp represents the linear operating speed of the robot, v_rot
represents the rotational operating speed of the robot, v_leax represents the linear operating speed of the additional axis, v_reax represents the rotational
operating speed of the additional axis, if there is no additional axis, then No need to modify the two.
4. The customized data can be called in the RAPID program.
https://www.xmamazon.com
https://www.xmamazon.com
https://www.plcdcs.com/
www.module-plc.com/
https://www.ymgk.com
1769-L32E Allen-Bradley Programmable automation controller
1769-L30ERMS Allen-Bradley CompactGuardLogix controller
1769-L24ER-QBFC1B CompactLogix 5370 L2 controller
1769-IT6 Thermocouple / milivolt Input Module
1769-IF8 Compact I/O analog input module
1769-IA16 Allen-Bradley 16 Channel Input Module
1769-ADN DeviceNet communication module
1762-L40BWAR Programmable Logic Controller (PLC)
1762-IF4 Differential channels analog input module
1757-SRM ControlLogix System Redundancy Module
1756-TBNH removable terminal block or RTB module
1756-RMB ControlLogix Redundancy module
1756-RM redundant module
1756-OF8 analog output module
1756-PA75RA ControlLogix Redundant Power Supply
1756-OF4 ControlLogix Four (4) channel analog output module
1756-OB32 ControlLogix Discrete output module
1756-L542 Allen-Bradley SLC 5/03 controller
1756-L75 Allen-Bradley ControlLogix Controller
1756-L71S Programmable controller
1756-L71 ControlLogix Logix5571 processor module
1756-L61 ControlLogix controller
1756-IF8H ControlLogix I/O module
1756-IB32 Input module
1756-IB16 I/O module
1756-ENBT Optical fiber interface board module
1756-EN2TXT Ethernet /IP module
1756-EN2TR Communication module
1756-EN2TEthernet /IP module
1756-DNB Scanner module
1756-DHRIO Programmable controlle
1756-BATM Programmable logic controller
1756-A13 chassis
1755T-PMPP-1700 Touch screen
1755-A6 module
1747-SDN Communication module
1747-KE Communication module
1747-FC Input/output module
1747-DCM Input/output module
1747-C10 driver
1747-ACNR15 Processor module
1746-P4 Power module
1746-OV8 Programmable controller
1746-OB16E Allen-Bradley Programmable controller
1746-OA8 Programmable controller
1746-IV32 Allen-Bradley SLC 500 Discrete Input module
1746-A2 Programmable logic control
Reviews
There are no reviews yet.