Sale!

DS200TCDAH1B Reliable Turbine Control Solutions

Original price was: $1,888.00.Current price is: $1,688.00.

МодельDS200TCDAH1B

Первоначальная гарантия на один год.
DS200TCDAH1B Параметры

DS200TCDAH1B Размер 30 * 20 * 30
DS200TCDAH1B Вес 2 кг

Контактное лицо: г – н Рай

WeChat: 17750010683

WhatsApp: + 86 177500 10683

Электронная почта 3221366881@qq.com

Category:
Phone: +86 17750010683
Email: 3221366881@qq.com
connect:Mr. Lai

Description

(1) Use STEP7V5.2 configuration software and enter Hardware Configure to complete S7-300 PLC hardware configuration;

(2) Select S7-315-2DP as the main station system, import the GSD (device database) file of NPBA-12 into the STEP7 programming environment, and configure the software
to configure NPBA-12 with S7-315-2DP as the main station. DP online, and select the PPO type to use. This design uses PPO4 to set the site network address. In the Profibus
structure of the variable frequency drive device, ABB frequency converters use the Profibus-DP communication module (NPBA-12) for data transmission, which is
mainly periodic: the host reads the input information from the slave station and sends the output information back to the slave station. ,
so it is necessary to call two system function blocks SFC14 and SFC15 in the PLC main program to read and write these data to achieve communication control to
the frequency converter;

(3) Create a data block in the main PLC program for data communication with the frequency converter; establish a variable table for observing the real-time
communication effect.

4 Inverter operation settings

After the frequency converter and PLC are connected to a network using Profibus-DP fieldbus, in addition to programming in the PLC automation system,
appropriate parameter settings must also be performed on each frequency converter.

After the communication cable is connected, start the inverter and complete the setting of the inverter communication parameters.

4.1 Basic settings

(1) 51.01—Module type, this parameter displays the module model detected by the transmission device. Its parameter value cannot be adjusted by the
user. If this parameter is not defined, communication between the module and the drive cannot be established.

(2) 51.02—This parameter selects the communication protocol, “0” selects the Profibus-DP communication protocol.

(3) 51.03—This parameter is Profibu

The PPO type selected by s connection, “3” is PPO4, but the PPO type on the inverter should be consistent with the PPO type configured on the PLC.

(4) 51.04—This parameter is used to define the device address number, that is, the site address of the frequency converter. Each device on the Profibus
connection must have a separate address. In this design, the two frequency converters are stations 2 and 3 respectively. [1]

4.2 Connection of process parameters

The process parameter interconnection completes the definition and connection of the corresponding parameters of the NPBA-12 dual-port RAM
connector and the frequency converter, including the connection from the master station (PLC) to the frequency converter and the connection from the frequency
converter to the master station (PLC). Set the following connection parameters on the frequency converter.

(1) PZD value sent from PLC to transmission inverter

PZD1—control word, such as start enable, stop, emergency stop and other control commands of the frequency converter;

PZD2—frequency setting value of the inverter.

(2) PZD value sent from the transmission inverter to the PLC

PZD1—status word, such as alarm, fault and other inverter operating status;

PZD2—actual speed value, current actual value, etc. of the frequency converter.

5 Conclusion

After the inverter control system adopts the Profibus-DP fieldbus control mode, the entire system not only has strong reliability and is easy to operate, but also can
be flexibly modified according to process needs. After this system was applied in Jigang Baode Color Plate Co., Ltd., it has been running well and has provided a successful
example for the future automation equipment (network communication of different manufacturers) of the head office.

New technology from Swiss ABB Group: Complete car charging in 15 seconds

This technology can charge a car in 15 seconds

The Swiss ABB Group has developed a new electric bus technology that can complete vehicle charging in 15 seconds . No other company”s battery technology can achieve this performance.

ABB has developed a technology called “Flash Charging” that allows an electric bus with 135 passengers to charge at charging points along the route. The charging point has a
charging power of 400 kilowatts and is located above the vehicle. The charging point is connected to a moving arm controlled by a laser and can charge the car battery in 15 seconds. Its
minimal design will help protect the urban environment and surrounding landscape.

The idea behind this design is to give the electric bus enough power to travel to the next charging station after one charge. The end of the line will allow for long periods of full charging
, with the car able to travel longer distances on a full charge. In addition to faster charging times, the system uses a carbon-emission-free solution called
TOSA to obtain electricity from clean hydroelectric power stations.

ABB initially plans to use this technology between Geneva Airport and the Palexpo International Convention and Exhibition Center. If the test is successful
, it will be deployed to public transportation systems. This is more cost effective and environmentally friendly.

ABB Executive Chief Technology Officer Claes Rytoft said: “With flash charging, we can trial a new generation of electric buses for large-scale transportation
in cities. This project will provide greater flexibility, cost-effectiveness and flexibility.” Paving the way for a lower public transport system while reducing pollution and noise.”

TC514V2 3BSE013281R1 AF100 Twisted Pair/Optical modem
UNS0881A-PV2 7.5KV 3BHE033982R0010 Door Drive interface board
UNS0881a-P,V1 3BHB006338R0001 Control board
2711-B6C5 PanelView Standard terminal
VM600 IOC4T Vibro-meter Input/output card
VM600 RPS6U Vibro-meter Rack Power supply
IS215UCVEH2AB VMIVME-7614-132 350-007614-132C Mark VI controller
VE4022 PROFIBUS module
136703-01 3500/50 I/O module
IC754VSL06CTD-ML Operator interface terminal
HE693ADC410 Analog Input channel
TC561V2 3BSE022179R1 optical modem
DSDI110AK14 3BSE019927R1 Digital Input Kit 32 channels
CI535V24 3BSE022158R1 Main interface module
VM600 MPC4  Mechanical protection card
1SVR011700R0000 CC-E/STD Signal converter XIONGBA DCS
DSSX166 5347049-CR power distribution terminal equipment
CI545V01 3BUP001191R1 Precise Ethernet submodule
CI532V09 3BUP001190R1 Submodule interface
DSTX170 57160001-ADK connection unit
DSSR170 48990001-PC DC voltage regulator unit
DSTA145 57120001-HP analog board connection device
DSBB188 3BSE005004R1 Power bus Advant controller
DSSS171 3BSE005003R1 Switch Voting unit
DSBC174 3BSE012211R1 Bus Extender S100 I/O Bus
DO620 3BHT300009R1 Digital Output 32ch
AI630 3BHT300011R1 Analog input 12Ch
CI615 3BHT300024R1 I/O Extension Unit
AI635 3BHT300032R1 Analog input
AO650 3BHT300051R1 Analog output
DP640 3BHT300057R1 Tachometer module
CI630 3BSE011000R1 AF100 communication port
CI671 3BSE004043R1 Main field bus interface
CI630K01 3BSE011001R1 AF100 port kit to single cable
CI630K02 3BSE011002R1 AF100 port Kit to redundancy
DX610 3BSE013087R1 Digital input/output module
DI685 3BSE011613R1 S600 I/O digital input module
CI820V1 3BSE025255R1 AF100 Red Field bus
CI527A 3BSE035684R1 PCI to AF100 coupler
CI631 3BSE016347R1 Twisted Pair AF100 port
DSTK169 3BSE048791R1 Cable adapter
PU410K01 3BSE051826R1 RTA Communication Kit
CS513AK01 3BSE091971R1 RJ-45 Communication port
PCI-5114 8-bit digital converter
PCI-5122 14-bit PCI oscilloscope device PCI-5142
PCI-5142 Oscilloscope device PCI-5152
Pci-5153 8-bit PCI oscilloscope device
PCI-5152 Oscilloscope equipment
Pci-5154 8-bit PCI oscilloscope device
PCI-5922 oscilloscope equipment

Reviews

There are no reviews yet.

Be the first to review “DS200TCDAH1B Reliable Turbine Control Solutions”

Your email address will not be published. Required fields are marked *