user experience

Secondly, if power system engineers are to consider the convenience and speed of using the product in the future, operability needs to be improved while ensuring stability.
This requires a simple self-service system and an operation interface with good visual effects that can meet the needs of users. Some operating habits and other aspects

* cut costs

Furthermore, since there are many nodes in the power system, the same product needs to be deployed on many nodes. Then when the quantity of required products increases,
cost issues will inevitably be involved. How to solve the research and development, construction and installation of products and better reduce operating expenses is also a major issue that ABB needs to consider.

Implementation of communication between Omron vision system and ABB industrial robot

introduction

In modern production processes, vision systems are often used to measure and identify products, and then the results are transmitted to industrial robots for work
through communications . In this process, communication settings are very important. This article analyzes the communication implementation process between the Omron
FH-L550 vision system and ABB industrial robots. The main task is to enable the vision system to provide data detection results for ABB industrial robots, and the industrial robots
perform related operations based on the data results. This article mainly discusses the entire process of visual system communication transmission implementation.

1Ethernet-based communication settings in vision software

The main communication methods of Omron FH-L550 vision system controller are as follows [2], namely: parallel communication, PLCLINK communication, Ethernet
communication, EtherCAT communication, and protocol-free communication. These five communication methods have their own characteristics in the communication process.
In modern equipment, Ethernet communication
(Ethernet communication) is the most common, so this article uses the Ethernet communication method as an example to analyze and explain.

First, select the “Tools” option in the main interface, select the “System Settings” menu (Figure 1), after entering the “System Settings” menu, click the “Startup Settings” option,
and select the “Communication Module” tab (Figure 2 ), after completing the above settings, return to the main interface to save the settings (Figure 3). Finally, select the function
menu to perform system restart settings, and wait for the system to complete the restart before proceeding to the next step.

After the system restarts, click the “System Settings” menu again and select the “Ethernet (No Protocol (UDP))” option (Figure 4). In this option, there will be parameter settings
such as IP address and port. What needs to be noted here are the two IP address parameters. The parameters in “Address Setting 2” need to be filled in. The information that needs
to be filled in includes the IP address of the vision controller, subnet mask, default gateway and DNS server.
In the port number setting of “Input/Output Settings” at the bottom of the menu, set the port number for data input with the sensor controller. Note that the port number should
be the same as the host side, and finally complete the settings and corresponding data saving work.

2ABB industrial robot communication settings

First, configure the WAN port IP address for the ABB industrial robot. Select the control panel in the teach pendant, then select configuration, then select communication in
the theme, click IPSetting, set the IP information and click “Change” to save the IP information.

Next, use the SocketCreate robot command to create a new socket using the streaming protocol TCP/IP and assign it to the corresponding variable (Figure 5). Then
use the SocketConnect command to connect the socket to the remote computer. After the communication connection is completed, it is necessary to send and receive
information from the visual system. To send information, use the SocketSend instruction to send data instructions to the remote computer. After the vision system collects
information and makes judgments, the industrial robot system will receive data from the remote computer. The data reception is completed using the
SocketReceive instruction. This instruction stores the data in the corresponding string variable while receiving the data. Useful information needs to be extracted from the
received data information, which requires StrPart to find the specified character position instruction, extract the data at the specified position from the string, and assign the
result to a new string variable. Finally, when the socket connection is not in use, use SocketCloSe to close it.

149992-01 3500/33 Spare 16-Channel Relay Output Module
9199-00002 A6120 EMERSON Control card piece
135489-01 3500/42M  I/O module
125840-01 3500/15  High Voltage AC Power Input Module
330130-045-00-00  3300 XL Extension Cable
135489-03 3500/42M  I/O Module with Internal Barriers (4 Velomitor channels) and Internal Terminations
9199-00003 A6210 EMERSON I/O/DO module
125840-01 3500/15  High Voltage AC Power Input Module
125768-01 3500/20  RIM I/O Module
149992-01  Spare 16-Channel Relay Output Module
A3120/022-000 CSI3120 EMERSON Bearing-Vibration Monitor
3500/60  Resistance temperature detector
1900/55  General Purpose Equipment Monitor
3500/33 16 Channel Relay Module
330101-00-25-10-02-00  3300 XL 8 mm Proximity Probes, Metric
330130-040-00-00 3300 XL Standard Extension Cable
330130-085-00-05 3300 XL Standard Extension Cable
330180-X1-05 Modified Proximitor Sensor
A6110 9199-00001 EMERSON I/O/DO module
3500/25 Enhanced Keyphasor Module
3500/20 Rack Interface Module
3500/93 series system display
3500/42M Position Monitor
3500/53M  Electronic Overspeed Detection System
A6140 9199-00058 emerson Digital I/O module
3500/32 4-channel relay module
3500/45  4-channel  Position Monitor
3500/05-02-02 Axial displacement probe
A6220 9199-00009 EMERSON Ethernet module
135489-04  I/O Module With Internal Barriers And Internal Terminations
136703-01  3500/50 I/O Module with Internal Barriers and Internal Termination
135473-01 Proximitor/Seismic Monitor Module
125840-01  High Voltage AC Power Input Module
133396-01  Overspeed Detection I/O Module
138708-01 Shaft Absolute I/O Module with Internal Terminations
125760-01 Data Manager I/O Module
A6370D EMERSON Analog quantity input card
125680-01  Proximitor I/O Module
330980-51-05 XL NSv Proximitor Sensor
330850-90-05  3300 XL 25 mm Proximitor Sensor
136180-01 Communication Gateaway Module
149369-01  Enhanced Keyphasor Module
133388-01  3500/53 Overspeed Detection Module
A6410 EMERSON Output module
127610-01  3500/15 AC Power Supply Module
176449-02 Proximitor/Seismic Monitor
125744-02 Rack Interface Module