DS200TBQDG1AFF General Electric Processor Board Mark VI

Original price was: $1,888.00.Current price is: $1,688.00.

МодельDS200TBQDG1AFF

Первоначальная гарантия на один год.
DS200TBQDG1AFF Параметры

DS200TBQDG1AFF Размер 30 * 20 * 30
DS200TBQDG1AFF Вес 2 кг

Контактное лицо: г – н Рай

WeChat: 17750010683

WhatsApp: + 86 177500 10683

Электронная почта 3221366881@qq.com

Category:

Description

DS200TBQDG1AFF General Electric Processor Board Mark VI
DS200TBQDG1AFF General Electric Processor Board Mark VI
DS200TBQDG1AFF General Electric Processor Board Mark VI Product details:

DS200TBQDG1AFF Technical Manual

DS200TBQDG1AFF Weight:1.8KG
DS200TBQDG1AFF Size: 20* 20 * 10cm
DS200TBQDG1AFF instructions
DS200TBQDG1AFF PDF
DS200TBQDG1AFF  – это панель связи возбудителя для передачи данных между контроллерами.
666666 Описание функций
ISBus – это защищенный интерфейс связи GE, используемый для передачи данных между контроллерами M1, M2 и C возбудителя. EISB – это модуль с одним слотом и высотой 3U, расположенный в раме управления под DSPX.
DS200TBQDG1AFF  Сигналы тока и напряжения от магнитного поля генератора (включая, при необходимости, возбудитель) принимаются через волоконно – оптический разъем на передней панели и передаются в модуль обнаружения заземления.
Применение данных
У EISB нет светодиодных индикаторов, трамплинов или предохранителей.
Соединитель
Следующие волоконно – оптические разъемы расположены на передней панели платы и используются для приема и передачи сигналов преобразования частоты DS200TBQDG1AFF :
• Ввод напряжения постоянного тока на месте для генераторов с пластиной EDCF
• Ввод тока на панели EDCF в аэропорту постоянного тока
Ввод напряжения возбудителя EDCF (необязательно)
Ввод тока в возбудитель EDCF (необязательно)
• Ввод напряжения в детектор заземления
• Переключатель сброса напряжения на выходе из приемника заземления также вогнут за отверстие в нижней части передней панели
Contact person: Mr. Lai
Mobil:17750010683
WeChat:17750010683
WhatsApp:+86 17750010683

In the formula, a is the design acceleration/deceleration value: s is the current actual position value of the
elevator: V2 is the maximum speed of the elevator at this position.

Considering that the lifting system needs to enter the parking track at a low crawling speed when entering the
end of the stroke to avoid equipment damage caused by large mechanical impact, therefore, when there are still
1~5m away from the parking position, the lifting speed is limited to 0.5m/ below s.

Since the instantaneous speed before parking is very low, the position accuracy of the system”s parking can
be relatively improved, which is particularly important when the auxiliary shaft is lifted.

2.2 Design and implementation of security protection functions

Mines have particularly strict requirements on safety and reliability of hoist control systems [5]. While ensuring high
reliability of electrical control equipment, the control system also sets up multiple protections in key links where failures
may occur, and detects the actions and feedback signals of these protection devices in real time.

First of all, monitoring the operating status of the elevator is the top priority in the safety protection
function of the elevator control system. In the control system, the operating speed and position of the
motor are monitored at all times, and the current position and speed values ​​are compared with the system”s
designed speed and position curve. Once it is found that the
actual operating speed of the hoist exceeds the designed speed value, immediately Issue an emergency
stop command and strictly ensure that the lifting speed is within the safe monitoring range during the entire
lifting process. At the same time, position detection switches are
arranged at several locations in the wellbore, and these position detection switches correspond to specific
position values ​​and corresponding speed values. When the elevator passes these switches, if it is found through
encoder detection that the actual speed value and position deviate from the values ​​corresponding to the position
detection switch, the control system will also judge that it is in a fault state
and immediately implement an emergency stop.

In order to determine whether the encoder connected to the main shaft of the elevator drum is normal,
two other encoders are installed on the elevator. In this way, the position and speed detection values
​​of the three encoders are always compared. Once it is found that the deviation between the detection
value of one encoder and the detection value of the other two encoders exceeds the allowable range,
the control system will immediately consider it to have entered a fault state and implement an emergency stop. Protective action.

3 Conclusion

The efficient and safe operation of main well equipment is an important guarantee for its function.
In the application of mine hoist, the 800xA system designed speed curve, self-correction, various
self-diagnosis and protection functions according to the specific process characteristics of the main
shaft mine hoist, which has achieved good results in practical applications.

RELIANCE 57C430 Processor Module
RELIANCE 45C322 power supply module
RELIANCE 45C360 Analog output card
RELIANCE 45C313 Bracket assembly
RELIANCE 45C201 Remote I/O Processor.
RELIANCE0-57435 7010 processor module
RELIANCE 0-57419 input module
RELIANCE 0-57408 power module
RELIANCE 0-57407 DCS processor module
RELIANCE 0-57404 Network communication module
RELIANCE 0-57402 Output module
RELIANCE 0-57401  digital I/O drive
RELIANCE 0-57400 digital control system created
RELIANCE 0-57334- I/O rack
RELIANCE 0-846405-4R Driver board assembly
RELIANCE 0-57160-L Stabilized circuit board
RELIANCE 0-48652-4 printed circuit board
RELIANCE 0-48652-30 Calibration instrument panel
RELIANCE 0-419437-B AutoMax Interface Board
RELIANCE  DSA-MTR-40D2  DRIVE
RELIANCE 0-57400-A AC/DC input module
RELIANCE 0-57402-C utput module
RELIANCE 0-57405-C analog I/O drive module
RELIANCE 30V4060 GV3000/SE AC Drive
RELIANCE 57045 Spare parts module
RELIANCE 57412 Field voltage regulator module
RELIANCE 57421 Pulse Tach input module
RELIANCE 57C332 Rack assembly
RELIANCE 57C443  I/O Scanner Module
RELIANCE 57C652 module
RELIANCE 803.65.00 PC BOARD
RELIANCE 770.90.10 Autobus Interface Module
RELIANCE 805401-5R Rack assembly
RELIANCE DBU-400 driver
RELIANCE DM-20 Brushless servo driver
RELIANCE DSA-MTR-60D DRIVE CHOP DDS-TLII-MTR-60AMP
ICS Triplex T8202 I/O Power Supply
ICS Triplex T8331 I/O Module
ICS Triplex T8232 Power Pack
ICS TRIPLEX T8431 Trusted TMR 24Vdc Analogue Input Module
ICS Triplex T8233 power port
ICS Triplex T8220 Power Supply Module
ICS Triplex T8902 40 Channel module
ICS Triplex T8153 Communication module
ICS Triplex T8451 Trusted TMR 24 Vdc Digital Output Module
ICS Triplex T8832 60 channel Analogue Input
ICS Triplex T8231 Power Pack 24 Vdc 750 W, universal input, 24 Vdc out.
ICS Triplex T8432 Dual-channel analog input
ICS Triplex T8120 Processor interface adapter
ICS Triplex T8824 Trusted 40 Channel 120Vac Digital Input
ICS Triplex T8901 VFTA Fuse/Link Pack
ICS Triplex T8122 Processor Interface Adaptor
ICS Triplex T8850 Trusted 40 channel Analogue module
ICS Triplex T8802 Trusted 60 Channel 24 Vdc Digital Input FTA
ICS Triplex T8272 Vent & Baffle Unit
ICS Triplex T8192 TMR 24/48 Vdc Digital Output Module
ICS Triplex T8480 Trusted TMR Analogue Output ModuleT8480C

Reviews

There are no reviews yet.

Be the first to review “DS200TBQDG1AFF General Electric Processor Board Mark VI”

Your email address will not be published. Required fields are marked *