DS200SLCCG3AGH Параметры

DS200SLCCG3AGH Размер 30 * 20 * 30
DS200SLCCG3AGH Вес 2 кг

Контактное лицо: г – н Рай

WeChat: 17750010683

WhatsApp: + 86 177500 10683

Электронная почта 3221366881@qq.com

Category:

Description

In the formula, a is the design acceleration/deceleration value: s is the current actual position value of the
elevator: V2 is the maximum speed of the elevator at this position.

Considering that the lifting system needs to enter the parking track at a low crawling speed when entering the
end of the stroke to avoid equipment damage caused by large mechanical impact, therefore, when there are still
1~5m away from the parking position, the lifting speed is limited to 0.5m/ below s.

Since the instantaneous speed before parking is very low, the position accuracy of the system”s parking can
be relatively improved, which is particularly important when the auxiliary shaft is lifted.

2.2 Design and implementation of security protection functions

Mines have particularly strict requirements on safety and reliability of hoist control systems [5]. While ensuring high
reliability of electrical control equipment, the control system also sets up multiple protections in key links where failures
may occur, and detects the actions and feedback signals of these protection devices in real time.

First of all, monitoring the operating status of the elevator is the top priority in the safety protection
function of the elevator control system. In the control system, the operating speed and position of the
motor are monitored at all times, and the current position and speed values ​​are compared with the system”s
designed speed and position curve. Once it is found that the
actual operating speed of the hoist exceeds the designed speed value, immediately Issue an emergency
stop command and strictly ensure that the lifting speed is within the safe monitoring range during the entire
lifting process. At the same time, position detection switches are
arranged at several locations in the wellbore, and these position detection switches correspond to specific
position values ​​and corresponding speed values. When the elevator passes these switches, if it is found through
encoder detection that the actual speed value and position deviate from the values ​​corresponding to the position
detection switch, the control system will also judge that it is in a fault state
and immediately implement an emergency stop.

In order to determine whether the encoder connected to the main shaft of the elevator drum is normal,
two other encoders are installed on the elevator. In this way, the position and speed detection values
​​of the three encoders are always compared. Once it is found that the deviation between the detection
value of one encoder and the detection value of the other two encoders exceeds the allowable range,
the control system will immediately consider it to have entered a fault state and implement an emergency stop. Protective action.

3 Conclusion

The efficient and safe operation of main well equipment is an important guarantee for its function.
In the application of mine hoist, the 800xA system designed speed curve, self-correction, various
self-diagnosis and protection functions according to the specific process characteristics of the main
shaft mine hoist, which has achieved good results in practical applications.

HIEE320639R1 Analog output board ABB
HIEE320639R0001  Analog output board ABB
LT8978bV1 Analog output board ABB
LT8978bV1 HIEE320639R1  ABB
LT8978bV1 HIEE320639R0001  ABB
LT8978bV1 HIEE320639R0001 HIEE320639R1
LDSYN-101 3BHE005555R0101 ABB
3BHE005555R0101 Analog output board
LDSYN-101 Analog output board ABB
3BSE013177R1 Analog output board ABB
LDGRB-01 Analog output board ABB
LDGRB-01 3BSE013177R1   ABB
LD800HSE 3BDH000320R02   ABB
3BDH000320R02 Analog output board   ABB
LD800HSE Analog output board   ABB
HIEE320606R1 Analog output board   ABB
KX8974cV24 Analog output board   ABB
KX8974cV24 HIEE320606R1  ABB
HESG216678/B Analog output board ABB
IW93-2 HESG440356R1Analog output board
IW93-2 HESG440356R1 HESG216678/B
IT94-3 HESG440310R2 HESG112699/B ABB
HESG112699/B  Redundant module ABB
IT94-3 HESG440310R2  Redundant module
IOR810   Redundant module ABB
INSEM01   Redundant module ABB
INNPM12   Redundant module ABB
INNIS01   Redundant module ABB
INIT03   Redundant module ABB
INIIT13   Redundant module ABB
INIIT03   Redundant module ABB
IMSET01   Redundant module ABB
IMMPI01   Redundant module ABB
IMMFP12   Redundant module ABB
IMDSI14   Redundant module ABB
IMDSM04   Redundant module ABB
IMDS014   Redundant module ABB
IMDS003  Redundant module ABB
IMBLK01  Redundant module ABB
IMASI23  Redundant module ABB
IEPAS02  Redundant module ABB
IEPAS01  Redundant module ABB
IEMMU21  Redundant module  ABB
IDPG 940128102 Redundant module  ABB
ICSI16E1  Redundant module  ABB
ICSE08B5 FPR3346501R1012  ABB
FPR3346501R1012    Redundant module  ABB
ICSE08B5   Redundant module   ABB