Sale!

DS200RTBAG3AGC General Electric Processor Board Mark VI

Original price was: $1,888.00.Current price is: $1,688.00.

МодельDS200RTBAG3AGC

Первоначальная гарантия на один год.
DS200RTBAG3AGC Параметры

DS200RTBAG3AGC Размер 30 * 20 * 30
DS200RTBAG3AGC Вес 2 кг

Контактное лицо: г – н Рай

WeChat: 17750010683

WhatsApp: + 86 177500 10683

Электронная почта 3221366881@qq.com

Category:

Description

DS200RTBAG3AGC General Electric Processor Board Mark VI
DS200RTBAG3AGC General Electric Processor Board Mark VI
DS200RTBAG3AGC General Electric Processor Board Mark VI Product details:

DS200RTBAG3AGC Technical Manual

DS200RTBAG3AGC Weight:1.8KG
DS200RTBAG3AGC Size: 20* 20 * 10cm
DS200RTBAG3AGC instructions
DS200RTBAG3AGC PDF
DS200RTBAG3AGC  – это панель связи возбудителя для передачи данных между контроллерами.
666666 Описание функций
ISBus – это защищенный интерфейс связи GE, используемый для передачи данных между контроллерами M1, M2 и C возбудителя. EISB – это модуль с одним слотом и высотой 3U, расположенный в раме управления под DSPX.
DS200RTBAG3AGC  Сигналы тока и напряжения от магнитного поля генератора (включая, при необходимости, возбудитель) принимаются через волоконно – оптический разъем на передней панели и передаются в модуль обнаружения заземления.
Применение данных
У EISB нет светодиодных индикаторов, трамплинов или предохранителей.
Соединитель
Следующие волоконно – оптические разъемы расположены на передней панели платы и используются для приема и передачи сигналов преобразования частоты DS200RTBAG3AGC :
• Ввод напряжения постоянного тока на месте для генераторов с пластиной EDCF
• Ввод тока на панели EDCF в аэропорту постоянного тока
Ввод напряжения возбудителя EDCF (необязательно)
Ввод тока в возбудитель EDCF (необязательно)
• Ввод напряжения в детектор заземления
• Переключатель сброса напряжения на выходе из приемника заземления также вогнут за отверстие в нижней части передней панели
Contact person: Mr. Lai
Mobil:17750010683
WeChat:17750010683
WhatsApp:+86 17750010683

(1) Use STEP7V5.2 configuration software and enter Hardware Configure to complete S7-300 PLC hardware configuration;

(2) Select S7-315-2DP as the main station system, import the GSD (device database) file of NPBA-12 into the STEP7 programming environment, and configure the software
to configure NPBA-12 with S7-315-2DP as the main station. DP online, and select the PPO type to use. This design uses PPO4 to set the site network address. In the Profibus
structure of the variable frequency drive device, ABB frequency converters use the Profibus-DP communication module (NPBA-12) for data transmission, which is
mainly periodic: the host reads the input information from the slave station and sends the output information back to the slave station. ,
so it is necessary to call two system function blocks SFC14 and SFC15 in the PLC main program to read and write these data to achieve communication control to
the frequency converter;

(3) Create a data block in the main PLC program for data communication with the frequency converter; establish a variable table for observing the real-time
communication effect.

4 Inverter operation settings

After the frequency converter and PLC are connected to a network using Profibus-DP fieldbus, in addition to programming in the PLC automation system,
appropriate parameter settings must also be performed on each frequency converter.

After the communication cable is connected, start the inverter and complete the setting of the inverter communication parameters.

4.1 Basic settings

(1) 51.01—Module type, this parameter displays the module model detected by the transmission device. Its parameter value cannot be adjusted by the
user. If this parameter is not defined, communication between the module and the drive cannot be established.

(2) 51.02—This parameter selects the communication protocol, “0” selects the Profibus-DP communication protocol.

(3) 51.03—This parameter is Profibu

The PPO type selected by s connection, “3” is PPO4, but the PPO type on the inverter should be consistent with the PPO type configured on the PLC.

(4) 51.04—This parameter is used to define the device address number, that is, the site address of the frequency converter. Each device on the Profibus
connection must have a separate address. In this design, the two frequency converters are stations 2 and 3 respectively. [1]

4.2 Connection of process parameters

The process parameter interconnection completes the definition and connection of the corresponding parameters of the NPBA-12 dual-port RAM
connector and the frequency converter, including the connection from the master station (PLC) to the frequency converter and the connection from the frequency
converter to the master station (PLC). Set the following connection parameters on the frequency converter.

(1) PZD value sent from PLC to transmission inverter

PZD1—control word, such as start enable, stop, emergency stop and other control commands of the frequency converter;

PZD2—frequency setting value of the inverter.

(2) PZD value sent from the transmission inverter to the PLC

PZD1—status word, such as alarm, fault and other inverter operating status;

PZD2—actual speed value, current actual value, etc. of the frequency converter.

5 Conclusion

After the inverter control system adopts the Profibus-DP fieldbus control mode, the entire system not only has strong reliability and is easy to operate, but also can
be flexibly modified according to process needs. After this system was applied in Jigang Baode Color Plate Co., Ltd., it has been running well and has provided a successful
example for the future automation equipment (network communication of different manufacturers) of the head office.

New technology from Swiss ABB Group: Complete car charging in 15 seconds

This technology can charge a car in 15 seconds

The Swiss ABB Group has developed a new electric bus technology that can complete vehicle charging in 15 seconds . No other company”s battery technology can achieve this performance.

ABB has developed a technology called “Flash Charging” that allows an electric bus with 135 passengers to charge at charging points along the route. The charging point has a
charging power of 400 kilowatts and is located above the vehicle. The charging point is connected to a moving arm controlled by a laser and can charge the car battery in 15 seconds. Its
minimal design will help protect the urban environment and surrounding landscape.

The idea behind this design is to give the electric bus enough power to travel to the next charging station after one charge. The end of the line will allow for long periods of full charging
, with the car able to travel longer distances on a full charge. In addition to faster charging times, the system uses a carbon-emission-free solution called
TOSA to obtain electricity from clean hydroelectric power stations.

ABB initially plans to use this technology between Geneva Airport and the Palexpo International Convention and Exhibition Center. If the test is successful
, it will be deployed to public transportation systems. This is more cost effective and environmentally friendly.

ABB Executive Chief Technology Officer Claes Rytoft said: “With flash charging, we can trial a new generation of electric buses for large-scale transportation
in cities. This project will provide greater flexibility, cost-effectiveness and flexibility.” Paving the way for a lower public transport system while reducing pollution and noise.”

Emerson Delta V KJ3001X1-BB1 Host module
Emerson Delta V KJ3004X1-BA1 Digital volume signal board module
EMERSON KJ2002X1-CA1  I/O modules
TRICONEX 3623T Controller module
LDSYN-101 3BHE005555R0101 ABB  Dc module
LDMUI-001 61320946C ABB Control system module
IMBLK01 ABB I/O communication modules
4D33900G19 WESTINGHOUSE Servo driver
5A26304G02 WESTINGHOUSE Digital quantity module
OMRON NE2A-END relay
4135A HIMA Safety relay
TSXP571634M Schneider Ethernet module
ABB HIEE405246R0002 UNS 0867 A-P V2  DCS system module
SST-PB3-PCU SST Digital quantity module
Parker GV6K-U6E Servo Drive / Controller
Fireye BLL510 Display screen
FEMA traffic switch ASW454
1794-ASB A-B Controller/inverter
1756-EN2TR A-B Analog module
250Х56R 2RRE45 ECOFIT High volume turbofan
8V1180.00-2 B&R PLC controller
6SN1118-0DJ21-0AA1 SIEMENS Digital input card
6GK7542-5FX00-0XE0 Communication module SIEMENS
6ES7341-1CH02-0AE0 SIEMENS Redundant power modules
5PC910.SX02-00 B&R CPU controller
3RT1916-1BB00 SIEMENS relay
PHOENIX IB ST ZF 24 AI 4/SF-2750620 CONTACT I/O module
PHOENIX IB ST 24 AI 4SF-2754309 I/O module
INDRAMAT MAC112C-0-ED-2-C/130-B-0 servomotor
INDRAMAT MAC112D-0-ED-2-C/180-A-0/S011 motor
INDRAMAT MAC112C-0-HD-4-C/180-A-0/WI516LV/SO11 motor
INDRAMAT KDS1.3-200-300-W1 Ac servo driver
INDRAMAT KDS1.3-150-300-W1 Ac servo driver
KDV2.2-100-200/300-220 INDRAMAT Ac servo power supply
280D-F12Z-10B-CR A-B ArmorStart Starter
FBM218 FOXBORO Communication module
SM50/100-T BOSCH Processor module
SIEMENS 6ES7952-1AK00-0AA0 Memory card
PHOENIX 2961192 relay
MTL MTL5541 Safety grid
TRICONEX 1600071-001 Network communication card
POWERBOX PU200-31C DO module

Reviews

There are no reviews yet.

Be the first to review “DS200RTBAG3AGC General Electric Processor Board Mark VI”

Your email address will not be published. Required fields are marked *