DS200ITXSG1ABB General Electric Processor Board Mark VI

Original price was: $1,888.00.Current price is: $1,688.00.

МодельDS200ITXSG1ABB

Первоначальная гарантия на один год.
DS200ITXSG1ABB Параметры

DS200ITXSG1ABB Размер 30 * 20 * 30
DS200ITXSG1ABB Вес 2 кг

Контактное лицо: г – н Рай

WeChat: 17750010683

WhatsApp: + 86 177500 10683

Электронная почта 3221366881@qq.com

Category:

Description

Implementation of communication between ABC industrial robot and PLC based on DeviceNet fieldbus technology
introduction

In modern production systems, industrial robots and PLCs need to communicate and collaborate to complete production tasks. That is, the
industrial robots output signals to the PLC, allowing the PLC to control related equipment to drive the robot”s front-end tools. This article
mainly analyzes the communication problems between ABB industrial robots and PLC based on DeviceNet fieldbus technology.
DeviceNet is a common network communication method in the field of automation. ABB industrial robots establish a network to communicate with
Siemens PLC based on the DeviceNet network.

1Configure DSQC652

There are mainly 5 types of standard I/0 boards commonly used in ABB industrial robots [2]. Except for the different addresses assigned to
them during setup, their configuration methods are basically the same. This article mainly analyzes the ABB standard I/0 board DS0C652, which
mainly builds communication modules based on the DeviceNet network. The DS0C652 board has a distributed I/O module with 16 digital input and 16
digital output interfaces. The board is installed in the ABB industrial robot control cabinet. First, define the specific operation steps of the DS0C652 board,
enter the teach pendant control panel, then enter the configuration menu (Figure 1), select the DeviceNetDevice menu, and add a template to enter Figure 2.
ABB standard I/0 board is hung on the DeviceNet
network, so the address of the module in the network must be set. The jumpers 6 to 12 of terminal x5 are used to determine the address of the module.
The available address range is 10 to 63. Modify the parameters in the template parameters to complete the DS0C652 board settings. Click the drop-down
menu to select the “Use value from template” row, select
“DS0C65224VDCI/0Device”, and then the parameters that need to be set include the address of the I/0 board in the bus.
Figure 1 Configuring DSQC652

2Configure signals and parameters

After completing the DS0C652 board setting, the I/0 signal setting will be performed. Setting the I/0 signal is the basis for establishing communication with
the PLC. The PLC communicates and transmits data with the ABB industrial robot through the I/0 signal and the DS0C652 board. As shown in Figure 3, in the
signal configuration interface, there are many default I/0 points after the system is established. Modification is not allowed. Click “Add” to add signals. When setting
input and output signals, their address range is 0~15. First, enter the signal menu in the configuration options to set the input and output types, and modify the corresponding parameters.
After completing the settings, the computer prompts that you need to restart the settings. If there are multiple signals that need to be defined and the waiting time
is long after restarting multiple times, you can click “Cancel” and wait for all signals to be defined before clicking the “Yes” button to restart. After the signal settings are
completed, click to select “Input and Output” in the ABB menu to check whether all signals have been set.
Figure 2 Configure DSQC652 parameters
Figure 3 Signal parameter settings

During the signal establishment process, attention should be paid to the DSoC652 port and PLC port addresses used, and the corresponding address table should be
established, as shown in Table 1. The robot interacts with the PLC through I/O signals. During the setting process, there must be no errors in the port and address number
of the PLC connected to the DSoC652. If the address is set incorrectly, the communication between the robot and the PLC will not work properly.

The entire robot teaching pendant setting process is shown in Figure 4.

FCS01.1E-W0011-A-04-NNBV R911311065 Electric Drive and Control
PP825A 3BSE042240R3 5.7 “resistive Touch Panel
PFEA112-20 3BSE030369R0020 PFEA Series Z Tension Controller
PR6423/010-140+CON021 electric sensor
05701-A-0550 Analysis System 57 Calibration plug
H32NCHA-LNN-NS-00 PACIFIC  H series hybrid stepping motor
6104-WA-PDPM Wireless PROFIBUS gateway
A6824 9199-00090 AMS 6500Machinery Health module
A6410 9199-00005 Mechanical expansion unit
A6110 9199-00001 ModBus and Rack interface module
IS420ESWBH3A 16-PORT IONET SWITCH
VMIACC-5595-200 Reflection memory hub
CC-IP0101 51410056-175 Experion Series -C I/O components
ACC-5595-208 350-805595-208N Gateway switch
IC695CRU320-EJ Redundant CPU RX3i PacSystem
AO2000 LS25 Advance Optima Continuous gas analysis
VMIVME-7740-850 Board Pentium III processor
SGDA-01BS servo package
SGDA-03BS servo package
SGDA-02BS servo package
SGDA-A5BS servo package
SGDA-01AS servo package
SGDA-A5AS servo package
SGDA-01BP traditional servo amplifier
SGDA-04ASY238 servo package
SGDA-01AP servo package
SGDA-04VS servo amplifier
SGDH-15AE-S servo package
SGDH-30DE-OY servo amplifier
SGDH-05AE Servo package
DR1B-02AC AC servo driver
DR1-08ACY25 basic mechatronics driver
DR1-08ACY24 AC servo driver
DR2-A5AC-NY41 DR2 servo module
DR2-01ACY103 DR2 servo component
DR2-A3AC-NY41 DR2 servo component
DR2-02AC-NY41 DR2 servo component
1C31233G04 Channel 16 input module
1C31232G02 Channel 16 input module
5X00622G01 Analog input board
5X00622G01 Analog input board
TPMC871-10 TEWS single width 32-bit PMC module
ICSE08B5 FPR3346501R1012  I/O module
1785-ME64/A PLC 5 Storage device module
VE4003S2B1 Standard I/O terminal board
T8403C Trusted®TMR Expansion Processor module
KJ3002X1-BF1 12P1732X042 Ethernet link controller I/O module
RELIANCE 45C992 Analog input module
1C31222G01 WESTINGHOUSE OVATION PLC RELAY OUTPUT
5X00497G01 Power distribution module
133442-01 Bently Nevada I/O Module  Internal Terminations
5X00502G01 PLC relay output module
1C31132G01 Analog Output Module
5X00502G01 PLC relay output module
1C31132G01 Analog Output Module
1C31227G01 8-channel analog input
1756-EN2T ControlLogix Communication module
5X00226G04 Ovation I/O interface controller
1C31189G03 Ovation I/O Interface Controller

Reviews

There are no reviews yet.

Be the first to review “DS200ITXSG1ABB General Electric Processor Board Mark VI”