Sale!

DS200IIBDG1AFA Reliable Turbine Control Solutions

Original price was: $1,888.00.Current price is: $1,688.00.

МодельDS200IIBDG1AFA

Первоначальная гарантия на один год.
DS200IIBDG1AFA Параметры

DS200IIBDG1AFA Размер 30 * 20 * 30
DS200IIBDG1AFA Вес 2 кг

Контактное лицо: г – н Рай

WeChat: 17750010683

WhatsApp: + 86 177500 10683

Электронная почта 3221366881@qq.com

Category:

Description

DS200IIBDG1AFA Reliable Turbine Control Solutions
DS200IIBDG1AFA Reliable Turbine Control Solutions
DS200IIBDG1AFA Reliable Turbine Control Solutions Product details:

DS200IIBDG1AFA Technical Manual

DS200IIBDG1AFA Weight:1.8KG
DS200IIBDG1AFA Size: 20* 20 * 10cm
DS200IIBDG1AFA instructions
DS200IIBDG1AFA PDF
DS200IIBDG1AFA  – это панель связи возбудителя для передачи данных между контроллерами.
666666 Описание функций
ISBus – это защищенный интерфейс связи GE, используемый для передачи данных между контроллерами M1, M2 и C возбудителя. EISB – это модуль с одним слотом и высотой 3U, расположенный в раме управления под DSPX.
DS200IIBDG1AFA  Сигналы тока и напряжения от магнитного поля генератора (включая, при необходимости, возбудитель) принимаются через волоконно – оптический разъем на передней панели и передаются в модуль обнаружения заземления.
Применение данных
У EISB нет светодиодных индикаторов, трамплинов или предохранителей.
Соединитель
Следующие волоконно – оптические разъемы расположены на передней панели платы и используются для приема и передачи сигналов преобразования частоты DS200IIBDG1AFA :
• Ввод напряжения постоянного тока на месте для генераторов с пластиной EDCF
• Ввод тока на панели EDCF в аэропорту постоянного тока
Ввод напряжения возбудителя EDCF (необязательно)
Ввод тока в возбудитель EDCF (необязательно)
• Ввод напряжения в детектор заземления
• Переключатель сброса напряжения на выходе из приемника заземления также вогнут за отверстие в нижней части передней панели
Contact person: Mr. Lai
Mobil:17750010683
WeChat:17750010683
WhatsApp:+86 17750010683

We can perform simulation algorithms on Matlab.
3. The role of frequency converter

1. Frequency conversion energy saving

The energy saving of frequency converters is mainly reflected in the application of fans and water pumps. In order to ensure the reliability of production, various
production machines have a certain margin when they are designed to be equipped with power drives. When the motor cannot operate at full load, in addition to
meeting the power drive requirements, the excess torque increases the consumption of active power, resulting in a waste of electrical energy. The traditional speed
adjustment method for fans, pumps and other equipment is to adjust the air supply volume and water supply volume by adjusting the opening of the baffles and valves
at the inlet or outlet. The input power is large, and a large amount of energy is consumed in the interception process of the baffles and valves. middle. When using variable
frequency speed regulation, if the flow requirement is reduced, the requirement can be met by reducing the speed of the pump or fan.

The purpose of using a frequency converter for a motor is to regulate speed and reduce starting current. In order to produce variable voltage and frequency, the device first converts
the alternating current from the power supply into direct current (DC), a process called rectification. The scientific term for a device that converts direct current (DC) into alternating
current (AC) is “inverter”. Generally, an inverter converts DC power into an inverter power supply with a certain fixed frequency and voltage. The inverter with adjustable frequency and
adjustable voltage is called a frequency converter. The waveform output by the frequency converter is a simulated sine wave, which is mainly used for speed regulation of three-phase
asynchronous motors, also called a variable frequency speed regulator. For variable frequency inverters that are mainly used in instrumentation and testing equipment and
have higher waveform requirements, the waveforms need to be sorted and can output standard sine waves, which are called variable frequency power supplies. Generally, the price
of variable frequency power supply is 15-20 times that of the inverter. Since the main device in the inverter equipment that produces changing voltage or frequency is called “inverter”,
the product itself is named “inverter”, that is: inverter.

Frequency conversion does not save power everywhere, and there are many occasions where using frequency conversion does not necessarily save power. As an electronic circuit,
the frequency converter itself also consumes power (about 3-5% of the rated power). A 1.5-horsepower air conditioner consumes 20-30W of electricity, which is equivalent to a
continuous light. It is a fact that the inverter runs at power frequency and has a power-saving function. But his prerequisite is:

DSSR122 4899001-NK  ABB  Power Supply Unit
DRIVER AZD-KD AZ Series EtherCAT Compatible Driver
CP-9200SHSVA  YOKOGAWA  Output relay
CI871K01  3BSE056767R1  ABB   Profinet IO Interface
CB06551  KOLLMORGEN  S600 servo drive
C7012E1104 HONEYWELL  Flame Sensor
BC810K01  ABB  CEX-Bus Interconnection Unit
AO2000-LS25  ABB  Integrated analyzer system
ACC-24E2A  Delta Tau  UMAC Turbo 4-Axis Analog Interface Module
3171197-4  MAN B&W  HMI Panel Module Marine Engine Controller Indicator
330709-000-050-10-02-00  Bently Nevada  3300 XL 11 mm Proximity Probes
330106-05-30-05-02-00  Bently Nevada  3300 XL 8 mm Reverse Mount Probes
5136-PFB-PCI  SST  Profibus Communications Adapter Module
3430-2 SAMSON Air operated regulator
3096-1000   APPLIED MATERIALS   radiometer
2301E 8273-1011  Woodward  Speed controller
683B-23795  MKS   throttle valve
469-P5-LO-A20-E  GE  LO Control Power with 4-20mA Analog Outputs
27E121  TE Connectivity   Relay socket and hardware
0190-24007  AMAT  Semiconductor board card
15I-2-FMO  Gecma Challenger  Remote PC Terminals
8V1090.00-2   B&R   ACOPOS servo drive
8LSA46.R0045D000-0  B&R  synchronous motor
4PP220.0571-R5  B&R Power Panel PP220 5.7″ QVGA color LC-display with touch screen
ND32-5610 ND32-5610VS-101-011-31 NOVOTRON  servo converter
D100644  METSO  Rev. 05 EFC Ethernet Coax Field Bus Converter Valmet
A404K  BASLER A404K   INDUSTRIAL CAMERA
PCD232A 3BHE022293R0101  ABB  Communication Interface
GFD233A103 3BHE022294R0103 ABB  Interface Module
GFD233A 3BHE022294R0103 ABB  Interface Module
CI871K01 3BSE056767R1 ABB  Profinet IO Interface
CAI04 ABB  CAI04
DO810 3BSE008510R1  ABB   16 digital outputs
DI04  ABB  DI module, 16-CH, 48 VDC
PM864AK01 3BSE018161R1 ABB  Processor Unit
9907-164  Woodward  505 Digital microprocessor-based Controllers
GPU/2 GS  DEIF  Generator paralleling controller
RMP201-8   KONGSBERG   DIGITAL INPUT MODULE
1785-ME64/A  Allen-Bradley  Memory Device
8200-1300  Woodward  integrated graphical front panel HMI
1756-RM/A  Allen-Bradley  ControlLogix enhanced redundancy module
1756-L63/B  Allen-Bradley  5560 ControlLogix Programmable Automation Controller (PAC)
1756-L61/B Allen-Bradley  standard ControlLogix series controller
1756-EN2T/B  Allen-Bradley  communication module