Sale!

DS200DSFBG1AEB GE Mark VI

Original price was: $1,888.00.Current price is: $1,688.00.

МодельDS200DSFBG1AEB

Первоначальная гарантия на один год.
DS200DSFBG1AEB Параметры

DS200DSFBG1AEB Размер 30 * 20 * 30
DS200DSFBG1AEB Вес 2 кг

Контактное лицо: г – н Рай

WeChat: 17750010683

WhatsApp: + 86 177500 10683

Электронная почта 3221366881@qq.com

Category:

Description

DS200DSFBG1AEB GE Mark VI
DS200DSFBG1AEB GE Mark VI
DS200DSFBG1AEB GE Mark VI Product details:

DS200DSFBG1AEB Technical Manual

DS200DSFBG1AEB Weight:1.8KG
DS200DSFBG1AEB Size: 20* 20 * 10cm
DS200DSFBG1AEB instructions
DS200DSFBG1AEB PDF
DS200DSFBG1AEB  – это панель связи возбудителя для передачи данных между контроллерами.
666666 Описание функций
ISBus – это защищенный интерфейс связи GE, используемый для передачи данных между контроллерами M1, M2 и C возбудителя. EISB – это модуль с одним слотом и высотой 3U, расположенный в раме управления под DSPX.
DS200DSFBG1AEB  Сигналы тока и напряжения от магнитного поля генератора (включая, при необходимости, возбудитель) принимаются через волоконно – оптический разъем на передней панели и передаются в модуль обнаружения заземления.
Применение данных
У EISB нет светодиодных индикаторов, трамплинов или предохранителей.
Соединитель
Следующие волоконно – оптические разъемы расположены на передней панели платы и используются для приема и передачи сигналов преобразования частоты DS200DSFBG1AEB :
• Ввод напряжения постоянного тока на месте для генераторов с пластиной EDCF
• Ввод тока на панели EDCF в аэропорту постоянного тока
Ввод напряжения возбудителя EDCF (необязательно)
Ввод тока в возбудитель EDCF (необязательно)
• Ввод напряжения в детектор заземления
• Переключатель сброса напряжения на выходе из приемника заземления также вогнут за отверстие в нижней части передней панели
Contact person: Mr. Lai
Mobil:17750010683
WeChat:17750010683
WhatsApp:+86 17750010683

ABB smart hotel integrated ecosystem

In addition, facing the vast C-end market, ABB has also been thinking about how to make the C-end business
better based on the successful operation of the B-end and provide a better user experience for C-end users.
ABB uses an open cooperation platform to digitally connect all smart networks in the home. Zou
Enchang emphasized that ABB also attaches great importance to network security, especially privacy protection.
It is understood that ABB has cooperated with many large companies at the cloud level. In foreign markets, it has
carried out platform cooperation with Microsoft, while in
China it has promoted cloud cooperation with Huawei . For ABB, the company”s strength is power distribution.
It integrates further needs of the power distribution end and continuously improves the creation of ABB”s overall ecosystem.

Realize smart electricity use and promote digital transformation

With the digital transformation of real estate, promoting the implementation of smart homes
based on real estate projects and large-scale applications are currently hot spots in the
domestic smart home industry. Focusing on the
development of smart communities under the trend of real estate digitalization, ABB will further
integrate its building intercom and smart home businesses to better provide relevant support and
services to B-side and C-side users. Zou Enchang pointed out that if real estate developers
want to improve the quality of the real
estate industry, they must first build smart communities, which include outdoor public areas and indoor
smart homes. For ABB, the first priority is its video intercom products. Based on in-depth communication
with major real estate developers, ABB develops products according to
needs. At the same time, while meeting the needs of domestic users, it can also promote products to foreign markets.

General Motors and ABB develop electric energy storage batteries with potential for secondary use

Recently, General Motors and ABB Group , the world”s largest power grid system supplier , jointly
released a new electrical energy storage system that allows electric vehicle power batteries to be reused after they are scrapped.

General Motors” recent research shows that 33 Chevrolet Volt extended-range electric vehicle batteries
can store enough energy to power 50 homes for about four hours
in the event of a power outage. It is reported that the new system combines electric vehicle batteries
and electric energy inverters connected to the power grid, and uses the power grid to store electricity
during low power consumption periods to meet power demand during peak
periods. At the same time, the battery pack can also be used as backup during power outages and
power restrictions. power supply.

At the same time, the two companies are working together to develop related equipment with a
view to allowing the energy stored in the battery pack of the Chevrolet Volt extended-range electric
vehicle to be fed back to the grid .

RELIANCE 805427-1S Resistance scaling module
RELIANCE 805405-5R Field power module
RELIANCE 805405-3R SF3000 Single-Phase Field Power Module
RELIANCE 805405-1R Power Module
RELIANCE 805403-3R  field power module
RELIANCE 805403-2R Resistor Scaling Module
RELIANCE 805403-1R Resistor Scaling Module
RELIANCE 805402-R Automax Distributed Power System
RELIANCE 805401-S 3-Slot PMI Rack assembly
LAM Research 605-109114-004 GE V7668A-132L00W04 4-Port Gigabit Ethernet Card Module
RELIANCE 805401-7R 4-Slot Parallel Gate Amplifier Rack
RELIANCE 805401-3S AutoMax Distribution Power System
RELIANCE 805401-2S Power Module
RELIANCE 804100-RX Remote I/O Head module
RELIANCE 804100-RV complete module
RELIANCE 61C613 analog input module
RELIANCE 61C605 8-Channel Isolated Thermocouple Module
RELIANCE 61C544  RTD module
RELIANCE 61C542 16 Channel Input Module
RELIANCE 61C516 AC/DC Input Module
LAM Research 605-048878-001 GE FANUC VME-7671-421000 SBC Board
RELIANCE 61C540 16-Point Input Module
RELIANCE 61C515 16-Bit Input Module
RELIANCE 61C501 Input Module
RELIANCE 61C500 module
RELIANCE 61C366 Analog Output Module
RELIANCE 61C351Input module simulates track card
RELIANCE 61C365 Output Module
RELIANCE 61C351 Input Module Analog Rail Card
RELIANCE 61C350  I/O Module
RELIANCE 61C345 Analog Input Module
RELIANCE 61C346  Analog Rail created
RELIANCE 61C326 PLC interface module
RELIANCE 61C23 AutoMax Local I/O headers created by the DCS system
RELIANCE 61C22 Local I/O Head made
RELIANCE 58820 AutoMax DCS system designed by MBCN
RELIANCE 57C570 AutoMax PC3000 Processor
RELIANCE 57C565 Optional string andante
RELIANCE 57C560  PC3000 processor
RELIANCE 57C554 Remote I/O Shark Interface Module
RELIANCE 57C494 Power Supply Module
RELIANCE 57C493 Automax Power Supply
RELIANCE 57C491 Supply module
RELIANCE 57C463 Frequency Event Counter Module
RELIANCE 57C446 PLC Module
RELIANCE 57C445 PC link interface
RELIANCE 57C443 Remote I/O scanning module
RELIANCE 57C442 Interface Module
RELIANCE 57C441 created Modbus Plus Module
RELIANCE 57C440 Ethernet Communication Module
RELIANCE 57C439 7010 Automax processor
RELIANCE 57C435A AutoMax Processor Module
RELIANCE 57C435 7010 Processor Module
RELIANCE Processor Module 57C431