Sale!

DS200CTBAG1ADD General Electric Processor Board Mark VI

Original price was: $1,888.00.Current price is: $1,688.00.

МодельDS200CTBAG1ADD

Первоначальная гарантия на один год.
DS200CTBAG1ADD Параметры

DS200CTBAG1ADD Размер 30 * 20 * 30
DS200CTBAG1ADD Вес 2 кг

Контактное лицо: г – н Рай

WeChat: 17750010683

WhatsApp: + 86 177500 10683

Электронная почта 3221366881@qq.com

Category:
Phone: +86 17750010683
Email: 3221366881@qq.com
connect:Mr. Lai

Description

In the formula, a is the design acceleration/deceleration value: s is the current actual position value of the
elevator: V2 is the maximum speed of the elevator at this position.

Considering that the lifting system needs to enter the parking track at a low crawling speed when entering the
end of the stroke to avoid equipment damage caused by large mechanical impact, therefore, when there are still
1~5m away from the parking position, the lifting speed is limited to 0.5m/ below s.

Since the instantaneous speed before parking is very low, the position accuracy of the system”s parking can
be relatively improved, which is particularly important when the auxiliary shaft is lifted.

2.2 Design and implementation of security protection functions

Mines have particularly strict requirements on safety and reliability of hoist control systems [5]. While ensuring high
reliability of electrical control equipment, the control system also sets up multiple protections in key links where failures
may occur, and detects the actions and feedback signals of these protection devices in real time.

First of all, monitoring the operating status of the elevator is the top priority in the safety protection
function of the elevator control system. In the control system, the operating speed and position of the
motor are monitored at all times, and the current position and speed values ​​are compared with the system”s
designed speed and position curve. Once it is found that the
actual operating speed of the hoist exceeds the designed speed value, immediately Issue an emergency
stop command and strictly ensure that the lifting speed is within the safe monitoring range during the entire
lifting process. At the same time, position detection switches are
arranged at several locations in the wellbore, and these position detection switches correspond to specific
position values ​​and corresponding speed values. When the elevator passes these switches, if it is found through
encoder detection that the actual speed value and position deviate from the values ​​corresponding to the position
detection switch, the control system will also judge that it is in a fault state
and immediately implement an emergency stop.

In order to determine whether the encoder connected to the main shaft of the elevator drum is normal,
two other encoders are installed on the elevator. In this way, the position and speed detection values
​​of the three encoders are always compared. Once it is found that the deviation between the detection
value of one encoder and the detection value of the other two encoders exceeds the allowable range,
the control system will immediately consider it to have entered a fault state and implement an emergency stop. Protective action.

3 Conclusion

The efficient and safe operation of main well equipment is an important guarantee for its function.
In the application of mine hoist, the 800xA system designed speed curve, self-correction, various
self-diagnosis and protection functions according to the specific process characteristics of the main
shaft mine hoist, which has achieved good results in practical applications.

ABB  Input output module 3BHE019361R0101
ABB  Input output module  UFD203A101
ABB  UFD203A101 3BHE019361R0101
A-B I/O module  1771-WA-Z1
A-B I/O module  1771-WA
A-B I/O module  1771-WC-Z1
A-B I/O module  1771-WC
A-B I/O module  1771-WD-Z1
A-B I/O module  1771-WD
A-B I/O module  1771-WF
A-B I/O module  1771-WG-Z1
A-B I/O module  1771-WG
A-B I/O module  1771-WN-Z1
A-B I/O module  1771-WN
A-B I/O module  1772-LG
A-B I/O module  1783-MS10T
A-B I/O module  1784-KT
A-B I/O module 1784-KTX
A-B I/O module 1784-PKTXD
A-B I/O module 1785-CHBM
A-B I/O module  1785-L30A
A-B I/O module  1785-L30B
A-B I/O module 1785-L40B
A-B I/O module 1785-L40C15
A-B I/O module 1785-L80B
A-B I/O module 1785-LT
A-B I/O module 1785-ME64
A-B I/O module 1785-ME64/A
A-B I/O module 1785-TR10BT
A-B I/O module 1785-V40L
A-B I/O module 1785-V80B
A-B I/O module 1786-RPFRXL-B
A-B I/O module 1786-RPFRXL
A-B I/O module 1786-TPYR
A-B I/O module 1788-DNBO
A-B I/O module 1794-ACN
A-B I/O module 1794-ACN15
A-B I/O module 1794-ACNR15
A-B I/O module 1794-ASB-E
A-B I/O module 1794-ASB
A-B I/O module 1794-IV16
A-B I/O module 1794-OE4
A-B I/O module 1794-TB3
A-B I/O module 1797-IE8
A-B I/O module 1797-PS2E2/A
PROSOFT   MVI56E-MNETXT
A-B man-machine interface 2711-K10C1
A-B man-machine interface 2711-K10C15
A-B man-machine interface 2711-K10G1
A-B man-machine interface 2711-K10G9L1
A-B man-machine interface 2711-K3A10L1
A-B man-machine interface 2711-K5A1
A-B man-machine interface 2711-K6C15
A-B man-machine interface 2711-K6C20

Reviews

There are no reviews yet.

Be the first to review “DS200CTBAG1ADD General Electric Processor Board Mark VI”

Your email address will not be published. Required fields are marked *