Description
hardware flow control. It is an ideal choice in the field of industrial automation.
3.2 Upgrading of regulators and control systems
For the upgrade of the regulator, the original excitation control system cabinet structure is retained, and the entire system is upgraded by upgrading the board card.
Among them, the CoB main board, MUB measurement board, F10 input and output board, and LCP local control panel were replaced with the PEC800 controller,
CCM measurement control interface board, CIo comprehensive input and output board, and ECT excitation system control terminal in the Unitrol6800 system respectively.
For the upgrade of the power cabinet, since the power of the excitation system will not change during the transformation, the N-1 redundant configuration of the five
UNL3300 rectifier bridges in the original system has not been changed, but the control and measurement parts of the rectifier
bridge have been upgraded. And the fan circuit and power control part of the rectifier bridge have been upgraded. Among them, the signal interface board (PsI) was
changed to the rectifier bridge signal interface board (CsI), the circuit breaker of the rectifier bridge panel was changed from CDP to CCP, and the rectifier bridge control
interface board (CIN) was changed to the rectifier bridge control board (CCI).
For the upgrade of the demagnetization cabinet, the switch control part was mainly upgraded. By adding a CIo board to the switch cabinet and installing a special
power distributor and relay to control the demagnetization switch, the original PsI board was removed. Secondly, in the transformation of the current detection part,
the Hall element in the Unitrol5000 system was replaced by the current relay of the Unitrol6800 system.
For the upgrade of the excitation current measurement part, the rectifier side Hall element of the rectifier bridge was replaced with an AC side CT. Relying on the linearity of the
CT, the current sharing coefficient of the excitation system was increased to 0.98, so that the role of the rectifier bridge can be fully exerted in the system. .
For the upgrade of the fan power supply circuit of the rectifier cabinet, each power cabinet can independently control the power supply of the fans in the
cabinet to avoid the problem that if the power circuit relay fails in the original system, all the fans will not work.
3.3Unitrol6800 functional logic configuration points
The Unitrol6800 system adds PT slow-blow judgment logic, and defines the actions of PT slow-blow as alarm and channel switching. The system PT
slow-blow logic pressure difference is 2% to ensure sufficient sensitivity. Since some external reasons will cause the sequential increase or decrease of magnetic
commands, a special increase or decrease magnetic contact adhesion judgment logic has been added to effectively lock out external causes. At the same
time, it can
avoid the jitter of the relay on the increase or decrease magnetic circuit and ensure the stability of the circuit. The excitation temperature detection is used to
alarm in the system, but it cannot control the system tripping. The tripping intermediate relays K291 and K292 use high-power (≥5w) relays to avoid
the problem of tripping of the excitation system
due to signal interference.
4 Problems discovered during the transformation and their solutions
After upgrading the excitation system from Unitrol5000 to Unitrol6800, since the partition between the regulator cabinets of the original excitation switch
cabinet was removed and the mounting backplate of the regulator was moved forward, the hot air from the excitation switch cabinet will enter the excitation regulator
cabinet, causing the cabinet to be damaged. The internal temperature rises, and sometimes the temperature can even reach 45°C. In order to avoid problems caused
by high temperatures, partitions were added to reduce the temperature inside the switch cabinet and control the
temperature to 30°C.
During the maintenance process, if the grounding carbon brush of the generator is removed, it is easy to cause the rotor grounding relay isoLR275 to
malfunction. Therefore, during maintenance, the power supply of the grounding relay will be disconnected and the large shaft in the magnetic cabinet will be short-circuited.
5 Conclusion
Through the transformation of the excitation system, our company not only meets the needs of increasing the generator capacity, but also
eliminates the safety hazards of ARCnet failure or flat cable damage in the excitation system of the unit. It can find the fault point during maintenance
and prevent the unit from non-stop. event. The new board used in the new excitation system has modular characteristics, which can make online maintenance more
convenient, and because the boards use trigger pulse generation communication and optical fiber redundant communication, the stability of
information transmission is ensured. Avoid communication failures and damage to pulse lines.
https://www.xmamazon.com
https://www.xmamazon.com
https://www.plcdcs.com/
www.module-plc.com/
https://www.ymgk.com
SC560 3BSE008105R1 ABB
SC540 3BSE006096R1 ABB
3BSE006096R1 processing module ABB
SC540 processing module ABB
3BSE016237R1 processing module ABB
SC520M processing module ABB
SC520M 3BSE016237R1 ABB
ABB PM860K01 3BSE018100R1
3BSE018100R1 processing module
PM860K01 processing module
3BSE066490R1 processing module
PM856AK01 processing module
ABB PM856AK01 3BSE066490R1
HIEE300888R000 Programmable Control Module
UAC389AE02 Programmable Control Module
SC513 Communication module ABB
ABB 3BSE027070R10 Pillow type sensor
ABB PFCL201C 10KN Pillow type sensor
ABB 3BSE050090R20 Tension controller
ABB PFEA111-20 Tension controller
ABB PFEA111-20 3BSE050090R20
ABB PFEA111-65 3BSE028140R0065
3BSE028140R0065 Tension controller ABB
PFEA111-65 Tension controller ABB
ABB PFCL201C 10KN 3BSE027070R10
ABB 3BSE027070R10 Pillow type sensor
ABB PFCL201C 10KN Pillow type sensor
ABB 3BSE027070R20 Pillow type sensor
ABB PFCL201C 20KN Pillow type sensor
ABB PFCL201C 20KN 3BSE027070R20
WOODWARD easYgen-3000
WOODWARD easYgen-1500
WOODWARD easYgen-3500XT
WOODWARD easYgen-3500
WOODWARD easYgen-100
WOODWARD 8237-1368
WOODWARD 8237-1245
Woodward’s ProTech-GII 8237-1246
WOODWARD 8237-1367
WOODWARD 8237-1601
Woodward’s ProTech-GII 8237-1246
WOODWARD 8237-1597
3BHB000652R0101 Drive module ABB
3BHB003431R0101 Drive module ABB
KUC720AE101 Drive module ABB
KUC720AE101 3BHB000652R0101 ABB
KUC720AE101 3BHB003431R0101 ABB
KUC720AE101 3BHB003431R0101 3BHB000652R0101
GE IS215VCMIH2BB – vme communication interface card
FCP280 FOXBORO
WOODWARD 8237-1242
WOODWARD 8237-2596
WOODWARD 8237-2597
WOODWARD 8237-2607
WOODWARD 8237-1369
WOODWARD 8237-2601
WOODWARD 8440-1800
WOODWARD 8440-1925
WOODWARD 8440-1934
WOODWARD 8440-1546
WOODWARD 8440-1894
WOODWARD 8440-2096
WOODWARD 8440-2077
WOODWARD 8440-1809
8440-2050 Woodward easYgen-3000 Series
WOODWARD 8440-1878