Description
hardware flow control. It is an ideal choice in the field of industrial automation.
3.2 Upgrading of regulators and control systems
For the upgrade of the regulator, the original excitation control system cabinet structure is retained, and the entire system is upgraded by upgrading the board card.
Among them, the CoB main board, MUB measurement board, F10 input and output board, and LCP local control panel were replaced with the PEC800 controller,
CCM measurement control interface board, CIo comprehensive input and output board, and ECT excitation system control terminal in the Unitrol6800 system respectively.
For the upgrade of the power cabinet, since the power of the excitation system will not change during the transformation, the N-1 redundant configuration of the five
UNL3300 rectifier bridges in the original system has not been changed, but the control and measurement parts of the rectifier
bridge have been upgraded. And the fan circuit and power control part of the rectifier bridge have been upgraded. Among them, the signal interface board (PsI) was
changed to the rectifier bridge signal interface board (CsI), the circuit breaker of the rectifier bridge panel was changed from CDP to CCP, and the rectifier bridge control
interface board (CIN) was changed to the rectifier bridge control board (CCI).
For the upgrade of the demagnetization cabinet, the switch control part was mainly upgraded. By adding a CIo board to the switch cabinet and installing a special
power distributor and relay to control the demagnetization switch, the original PsI board was removed. Secondly, in the transformation of the current detection part,
the Hall element in the Unitrol5000 system was replaced by the current relay of the Unitrol6800 system.
For the upgrade of the excitation current measurement part, the rectifier side Hall element of the rectifier bridge was replaced with an AC side CT. Relying on the linearity of the
CT, the current sharing coefficient of the excitation system was increased to 0.98, so that the role of the rectifier bridge can be fully exerted in the system. .
For the upgrade of the fan power supply circuit of the rectifier cabinet, each power cabinet can independently control the power supply of the fans in the
cabinet to avoid the problem that if the power circuit relay fails in the original system, all the fans will not work.
3.3Unitrol6800 functional logic configuration points
The Unitrol6800 system adds PT slow-blow judgment logic, and defines the actions of PT slow-blow as alarm and channel switching. The system PT
slow-blow logic pressure difference is 2% to ensure sufficient sensitivity. Since some external reasons will cause the sequential increase or decrease of magnetic
commands, a special increase or decrease magnetic contact adhesion judgment logic has been added to effectively lock out external causes. At the same
time, it can
avoid the jitter of the relay on the increase or decrease magnetic circuit and ensure the stability of the circuit. The excitation temperature detection is used to
alarm in the system, but it cannot control the system tripping. The tripping intermediate relays K291 and K292 use high-power (≥5w) relays to avoid
the problem of tripping of the excitation system
due to signal interference.
4 Problems discovered during the transformation and their solutions
After upgrading the excitation system from Unitrol5000 to Unitrol6800, since the partition between the regulator cabinets of the original excitation switch
cabinet was removed and the mounting backplate of the regulator was moved forward, the hot air from the excitation switch cabinet will enter the excitation regulator
cabinet, causing the cabinet to be damaged. The internal temperature rises, and sometimes the temperature can even reach 45°C. In order to avoid problems caused
by high temperatures, partitions were added to reduce the temperature inside the switch cabinet and control the
temperature to 30°C.
During the maintenance process, if the grounding carbon brush of the generator is removed, it is easy to cause the rotor grounding relay isoLR275 to
malfunction. Therefore, during maintenance, the power supply of the grounding relay will be disconnected and the large shaft in the magnetic cabinet will be short-circuited.
5 Conclusion
Through the transformation of the excitation system, our company not only meets the needs of increasing the generator capacity, but also
eliminates the safety hazards of ARCnet failure or flat cable damage in the excitation system of the unit. It can find the fault point during maintenance
and prevent the unit from non-stop. event. The new board used in the new excitation system has modular characteristics, which can make online maintenance more
convenient, and because the boards use trigger pulse generation communication and optical fiber redundant communication, the stability of
information transmission is ensured. Avoid communication failures and damage to pulse lines.
Display operation panel CB220B
Display operation panel CAI04
Display operation panel BSM0400CN00
Display operation panel BSFC-02C
Display operation panel BRC410
Display operation panel BRC410
Display operation panel BRC400
Display operation panel BRC400
Display operation panel BRC400
Display operation panel BRC3000A
Display operation panel BRC-300
Display operation panel BRC300
Display operation panel BRC300
Display operation panel BRC300
Display operation panel BRC200
Display operation panel BRC-100
Display operation panel BRC-100
Display operation panel BP914S
Display operation panel BP910S
Display operation panel BP901S
Display operation panel BIOC-01
Display operation panel BI934S
Display operation panel BI933S
Display operation panel BI924S
Display operation panel BI923S
Display operation panel BI914S
Display operation panel BI913S
Display operation panel BDD110 HNLP205879R1
Display operation panel BCU-02
Display operation panel BC810K02 3BSE031155R1
Display operation panel BC810K02
Display operation panel BC810K02
Display operation panel BC810K02
Display operation panel BC810K01 3BSE031154R1
Display operation panel BC810K01
Display operation panel BC810
Display operation panel BC25
Display operation panel BB174
Display operation panel Bailey PCM-10
Display operation panel B5EEd HENF105082R4
Display operation panel B5EC HENF105077R1
Display operation panel B3EA HENF315147R1
Display operation panel AX722F
Display operation panel AX721F
Display operation panel AX670 3BSE000566R1
Display operation panel AX670
Display operation panel ATPU-02A 3HNA004440-001
Display operation panel ASFC-01C
Display operation panel ASDI-03 3HNA010255-001
Display operation panel ARC093AV1 HIEE300690R1
Display operation panel ARC093AV1
Display operation panel APSAF03
Display operation panel APIP-05 3HNA018573-001
Display operation panel APBU-44C 64669982
Display operation panel APBU-44C
Display operation panel APBU-44C
Display operation panel AOFC-02
Display operation panel AO930S
Display operation panel AO930N
Display operation panel AO930B
Display operation panel AO920S
Display operation panel AO920N
Display operation panel AO920B
Display operation panel AO910S
Display operation panel AO910S
Display operation panel AO910N
Display operation panel AO910B
Display operation panel AO910
Display operation panel AO895 3BSC690087R1
Display operation panel AO895
Display operation panel AO890
Display operation panel AO890
Display operation panel AO845A-eA
Display operation panel AO845A/3BSE045584R1
Display operation panel AO845A
Display operation panel AO845
Display operation panel AO820-eA
Display operation panel AO820
Display operation panel AO820
Display operation panel AO815-eA
Display operation panel AO815
Display operation panel AO815
Display operation panel AO810V2-eA
Display operation panel AO810V2 3BSE038415R1
Display operation panel AO810V2 3BSE038415R1
Display operation panel AO810V2
Display operation panel AO810V2
Display operation panel AO810 3BSE008522R1
Display operation panel AO810
Display operation panel AO801-eA
Display operation panel AO801
Display operation panel AO801
Display operation panel AO801
Display operation panel AO723F
Display operation panel AO650 3BHT300051R1
Display operation panel AO610
Display operation panel AO610
Reviews
There are no reviews yet.