Sale!

8201-HI-IS Exciter terminal board

Original price was: $1,888.00.Current price is: $1,688.00.

Модель8201-HI-IS

Первоначальная гарантия на один год.
8201-HI-IS Параметры

8201-HI-IS Размер 30 * 20 * 30
8201-HI-IS Вес 2 кг

Контактное лицо: г – н Рай

WeChat: 17750010683

WhatsApp: + 86 177500 10683

Электронная почта 3221366881@qq.com

Category:

Description

8201-HI-IS Exciter terminal board
8201-HI-IS Exciter terminal board
8201-HI-IS Exciter terminal board Product details:

8201-HI-IS Technical Manual

8201-HI-IS Weight:1.8KG
8201-HI-IS Size: 20* 20 * 10cm
8201-HI-IS instructions
8201-HI-IS PDF
8201-HI-IS  – это панель связи возбудителя для передачи данных между контроллерами.
666666 Описание функций
ISBus – это защищенный интерфейс связи GE, используемый для передачи данных между контроллерами M1, M2 и C возбудителя. EISB – это модуль с одним слотом и высотой 3U, расположенный в раме управления под DSPX.
8201-HI-IS  Сигналы тока и напряжения от магнитного поля генератора (включая, при необходимости, возбудитель) принимаются через волоконно – оптический разъем на передней панели и передаются в модуль обнаружения заземления.
Применение данных
У EISB нет светодиодных индикаторов, трамплинов или предохранителей.
Соединитель
Следующие волоконно – оптические разъемы расположены на передней панели платы и используются для приема и передачи сигналов преобразования частоты 8201-HI-IS :
• Ввод напряжения постоянного тока на месте для генераторов с пластиной EDCF
• Ввод тока на панели EDCF в аэропорту постоянного тока
Ввод напряжения возбудителя EDCF (необязательно)
Ввод тока в возбудитель EDCF (необязательно)
• Ввод напряжения в детектор заземления
• Переключатель сброса напряжения на выходе из приемника заземления также вогнут за отверстие в нижней части передней панели
Contact person: Mr. Lai
Mobil:17750010683
WeChat:17750010683
WhatsApp:+86 17750010683

(1) Use STEP7V5.2 configuration software and enter Hardware Configure to complete S7-300 PLC hardware configuration;

(2) Select S7-315-2DP as the main station system, import the GSD (device database) file of NPBA-12 into the STEP7 programming environment, and configure the software
to configure NPBA-12 with S7-315-2DP as the main station. DP online, and select the PPO type to use. This design uses PPO4 to set the site network address. In the Profibus
structure of the variable frequency drive device, ABB frequency converters use the Profibus-DP communication module (NPBA-12) for data transmission, which is
mainly periodic: the host reads the input information from the slave station and sends the output information back to the slave station. ,
so it is necessary to call two system function blocks SFC14 and SFC15 in the PLC main program to read and write these data to achieve communication control to
the frequency converter;

(3) Create a data block in the main PLC program for data communication with the frequency converter; establish a variable table for observing the real-time
communication effect.

4 Inverter operation settings

After the frequency converter and PLC are connected to a network using Profibus-DP fieldbus, in addition to programming in the PLC automation system,
appropriate parameter settings must also be performed on each frequency converter.

After the communication cable is connected, start the inverter and complete the setting of the inverter communication parameters.

4.1 Basic settings

(1) 51.01—Module type, this parameter displays the module model detected by the transmission device. Its parameter value cannot be adjusted by the
user. If this parameter is not defined, communication between the module and the drive cannot be established.

(2) 51.02—This parameter selects the communication protocol, “0” selects the Profibus-DP communication protocol.

(3) 51.03—This parameter is Profibu

The PPO type selected by s connection, “3” is PPO4, but the PPO type on the inverter should be consistent with the PPO type configured on the PLC.

(4) 51.04—This parameter is used to define the device address number, that is, the site address of the frequency converter. Each device on the Profibus
connection must have a separate address. In this design, the two frequency converters are stations 2 and 3 respectively. [1]

4.2 Connection of process parameters

The process parameter interconnection completes the definition and connection of the corresponding parameters of the NPBA-12 dual-port RAM
connector and the frequency converter, including the connection from the master station (PLC) to the frequency converter and the connection from the frequency
converter to the master station (PLC). Set the following connection parameters on the frequency converter.

(1) PZD value sent from PLC to transmission inverter

PZD1—control word, such as start enable, stop, emergency stop and other control commands of the frequency converter;

PZD2—frequency setting value of the inverter.

(2) PZD value sent from the transmission inverter to the PLC

PZD1—status word, such as alarm, fault and other inverter operating status;

PZD2—actual speed value, current actual value, etc. of the frequency converter.

5 Conclusion

After the inverter control system adopts the Profibus-DP fieldbus control mode, the entire system not only has strong reliability and is easy to operate, but also can
be flexibly modified according to process needs. After this system was applied in Jigang Baode Color Plate Co., Ltd., it has been running well and has provided a successful
example for the future automation equipment (network communication of different manufacturers) of the head office.

New technology from Swiss ABB Group: Complete car charging in 15 seconds

This technology can charge a car in 15 seconds

The Swiss ABB Group has developed a new electric bus technology that can complete vehicle charging in 15 seconds . No other company”s battery technology can achieve this performance.

ABB has developed a technology called “Flash Charging” that allows an electric bus with 135 passengers to charge at charging points along the route. The charging point has a
charging power of 400 kilowatts and is located above the vehicle. The charging point is connected to a moving arm controlled by a laser and can charge the car battery in 15 seconds. Its
minimal design will help protect the urban environment and surrounding landscape.

The idea behind this design is to give the electric bus enough power to travel to the next charging station after one charge. The end of the line will allow for long periods of full charging
, with the car able to travel longer distances on a full charge. In addition to faster charging times, the system uses a carbon-emission-free solution called
TOSA to obtain electricity from clean hydroelectric power stations.

ABB initially plans to use this technology between Geneva Airport and the Palexpo International Convention and Exhibition Center. If the test is successful
, it will be deployed to public transportation systems. This is more cost effective and environmentally friendly.

ABB Executive Chief Technology Officer Claes Rytoft said: “With flash charging, we can trial a new generation of electric buses for large-scale transportation
in cities. This project will provide greater flexibility, cost-effectiveness and flexibility.” Paving the way for a lower public transport system while reducing pollution and noise.”

2213-75TSLKTB   JDSU   75mW Argon Laser (with rings)
1420-V2P-ENT  Allen-Bradley  monitoring system module
5X00121G01   Westinghouse   Switch quantity output module
6ES7716-2CB10-0EC4   Siemens   SIMATIC FIELD PG M4 PREMIUM PLUS
5X00119G01   Westinghouse    Controller Module
2N3A3110-C   TOSHIBA   Assembly Controller Board
1TGE120021R0010    ABB   Communication Gateway
2094-BM01-S   Allen-Bradley    Kinetix 6000 Drive component
FC-SDO-0824   Honeywell   Safety Manager System Module
FC-SAI-1620M   Honeywell Safety Manager System Module
FCS01.1E-W0011-A-04-NNBV   Rexroth   FC Frequency Converters
EX404MCRD5  TOSHIBA PROGRAMMABLE CONTROLLER
EVR116   PFEIFFER   Gas mass flowmeter intake control valve
EPC1200T-N270-2GB-40SS-XP   Nematron   Screen
ECU01.5  EMG display
EASYGEN 3200   Woodward   Series Genset Engine Controller
EL3068   BECKHOFF  analog input terminal processes signals
EGCP-3 8406-113   Woodward   Load Sharing EGCP-3 Model
E82ZAFP   LENZE COMMUNICATION MODULE
E84AHWMC1534V-V003   LENZE
E33NCHA-LNN-NS-00   Pacific Scientific   Hybrid Step Motor
DXA-205   EMERSON   Positioning Servo Drive
E111A12X3N  ETON CONTACTOR
DLD13004R   PARKER   Digital servoamplifier
DVC2000   Fisher  Digital Valve Controller
DKCXX.3-100-7  Rexroth DKC Drive Controllers
DDLS200/200.1-60   LENZE optical data transceiver
DB-5   Schneider   PacDrive Distribution Box
HD22010-3   EMERSON  Rectifier Module
AE6000-4   DITTEL   Grinding process monitoring module
HP 5517B   Agilent   Laser interferometer
CP451-10   Yokogawa Processor Module
XVME-653   Xycom   VMEbus Pentium Processor Module
ACC-24E2A 4-AXIS  Delta Tau Analog Interface Module
702060/188-888-000-23   Jumo Compact Microprocessor Controller
A860-2109-T302   FANUC  ALPHA-i 10,000 RPM SPINDLE CODER
805405-1R   RELIANCE   single-phase field power module
8222215.14.17  SEW CONTROL BOARD
XVM-403-TBNS-0000   EMERSON   Servo Motor
XV-430-12TSB-1-10   ETON  Touch Panel
3500/61   Bently Nevada   Temperature Monitors
VE4001S2T2B1   EMERSON   Discrete Input Card
330101-00-08-20-12-05   Bently Nevada   3300 XL 8mm Proximity Transducer Probe
146031-01  Bently Nevada Transient Data Interface I/O Module
8440-1706/A   Woodward   synchronizer modules
6186M-17PT   Allen-Bradley  display monitor
1756-PH75   Allen-Bradley   125 Volts DC Input Voltage
1381-648241-12  Tokyo Electron   PCB
1747-SDN   Allen-Bradley   SLC 500 DeviceNet Scanner Module
1747-L532   Allen-Bradley   SLC 5/03 controller module
839-13521-1   MKS   HPS Isolation Gate Valve
440R-W23222   Allen-Bradley   Safety Relay
620-0073C   HONEYWELL   ETHERNET LOOP PROCESSOR MODULE
90-20-0-003   CONTROL CHIEF   (2400) COMMUNICATION MODULE
85UVF1-1CEX Fireye Integrated Flame Scanner with Internal Flame Relay
TDM1.3-050-300-W1-000   Rexroth   TDM Drive Modules
07KT98   ABB   Basic Module Ethernet AC31
31C015-503-4-00   SEW   Movitrac Eurodrive AC Inverter Unit

Reviews

There are no reviews yet.

Be the first to review “8201-HI-IS Exciter terminal board”

Your email address will not be published. Required fields are marked *