Description
8115-DO-DC GE Fanuc Controller Carrie
высотой 3U, расположенный в раме управления под DSPX.
волоконно – оптический разъем на передней панели и передаются в модуль обнаружения заземления.
ABB: Запасные части для промышленных роботов серии DSQC, Bailey INFI 90, IGCT, например: 5SHY6545L0001 AC1027001R0101 5SXE10 – 0181, 5SHY3545 L0009, 5SHI3545L0010 3BHB013088 R0001 3BHE009681R0101 GVC750BE101, PM866, PM861K01, PM864, PM510V16, PPD512, PPPD113, PP836A, P865A, 877, PPP881, PPPP885, PPSL500000 4 3BHL00390P0104 5SGY35L4510 и т.д.
General Electric: запасные части, такие как модули, карты и приводы. Например: VMVME – 7807, VMVME – 7750, WES532 – 111, UR6UH, SR469 – P5 – HI – A20, IS230SRTDH2A, IS220PPDAH1B, IS215UCVEH2A, IC698CPE010, IS200SRTDH2ACB и т.д.
Система Bently Nevada: 350 / 3300 / 1900, предохранительные зонды и т.д., например: 3500 / 22M, 3500 / 32, 3500 / 15, 3500 / 23500 / 42M, 1900 / 27 и т.д.
Системы Invis Foxboro: Серия I / A, управление последовательностью FBM, трапециевидное логическое управление, обработка отзыва событий, DAC,
обработка входных / выходных сигналов, передача и обработка данных, такие как FCP270 и FCP280, P0904HA, E69F – TI2 – S, FBM230 / P0926GU, FEM100 / P0973CA и т.д.
Invis Triconex: Модуль питания, модуль CPU, модуль связи, модуль ввода – вывода, например 300830937214351B, 3805E, 831235114355X и т.д.
Вудворд: контроллер местоположения SPC, цифровой контроллер PEAK150, например 8521 – 0312 UG – 10D, 9907 – 149, 9907 – 162, 9907 – 164, 9907 – 167, TG – 13 (8516 – 038), 8440 – 1713 / D, 9907 – 018 2301A, 5466 – 258, 8200 – 226 и т.д.
Hima: модули безопасности, такие как F8650E, F8652X, F8627X, F8678X, F3236, F6217, F6214, Z7138, F8651X, F8650X и т.д.
Honeywell: Все платы DCS, модули, процессоры, такие как: CC – MCAR01, CC – PAIH01, CC – PAIH02, CC – PAIH51, CC – PAIX02, CC – PAON01, CC – PCF901, TC – CR014, TC – PD011, CC – PCNT02 и т.д.
Motorola: серии MVME162, MVME167, MVME172, MVME177, такие как MVME5100, MVME5500 – 0163, VME172PA – 652SE, VME162PA – 344SE – 2G и другие.
Xycom: I / O, платы VME и процессоры, такие как XVME – 530, XVME – 674, XVME – 957, XVME – 976 и т.д.
Коул Морган: Сервоприводы и двигатели, такие как S72402 – NANA, S6201 – 550, S20330 – SRS, CB06551 / PRD – B040SSIB – 63 и т. Д.
Bosch / Luxer / Indramat: модуль ввода / вывода, контроллер PLC, приводной модуль, MSK060C – 0600 – NN – S1 – UP1 – NNN, VT2000 – 52 / R900033828, MHD041B – 144 – PG1 – UN и т.д.
In the formula, a is the design acceleration/deceleration value: s is the current actual position value of the
elevator: V2 is the maximum speed of the elevator at this position.
Considering that the lifting system needs to enter the parking track at a low crawling speed when entering the
end of the stroke to avoid equipment damage caused by large mechanical impact, therefore, when there are still
1~5m away from the parking position, the lifting speed is limited to 0.5m/ below s.
Since the instantaneous speed before parking is very low, the position accuracy of the system”s parking can
be relatively improved, which is particularly important when the auxiliary shaft is lifted.
2.2 Design and implementation of security protection functions
Mines have particularly strict requirements on safety and reliability of hoist control systems [5]. While ensuring high
reliability of electrical control equipment, the control system also sets up multiple protections in key links where failures
may occur, and detects the actions and feedback signals of these protection devices in real time.
First of all, monitoring the operating status of the elevator is the top priority in the safety protection
function of the elevator control system. In the control system, the operating speed and position of the
motor are monitored at all times, and the current position and speed values are compared with the system”s
designed speed and position curve. Once it is found that the
actual operating speed of the hoist exceeds the designed speed value, immediately Issue an emergency
stop command and strictly ensure that the lifting speed is within the safe monitoring range during the entire
lifting process. At the same time, position detection switches are
arranged at several locations in the wellbore, and these position detection switches correspond to specific
position values and corresponding speed values. When the elevator passes these switches, if it is found through
encoder detection that the actual speed value and position deviate from the values corresponding to the position
detection switch, the control system will also judge that it is in a fault state
and immediately implement an emergency stop.
In order to determine whether the encoder connected to the main shaft of the elevator drum is normal,
two other encoders are installed on the elevator. In this way, the position and speed detection values
of the three encoders are always compared. Once it is found that the deviation between the detection
value of one encoder and the detection value of the other two encoders exceeds the allowable range,
the control system will immediately consider it to have entered a fault state and implement an emergency stop. Protective action.
3 Conclusion
The efficient and safe operation of main well equipment is an important guarantee for its function.
In the application of mine hoist, the 800xA system designed speed curve, self-correction, various
self-diagnosis and protection functions according to the specific process characteristics of the main
shaft mine hoist, which has achieved good results in practical applications.
PPC380AE02 HIEE300885R0102 ABB Output module
PR9268/307-100 9200-06121n EPRO Processor module
PFEA112-20 3BSE030369R0020 ABB Tension Electronics PFEA112
PM01 PM01-A-V001 TRICONEX Power management module
IS220PDIOH1B GE I/O pack
IS210AEDBH4AGD GE Mark VI printed circuit board
IS210AEBIH1BED GE Speedtronic Mark V Gas Turbine Control System
IOP313 METSO System domain network interface card
IOP310 METSO System domain network interface card
CM01 CM01-A-V001 TRICONEX Analog output module
DO3201 DO3201-A-V001 TRICONEX Analog output module
HC422B N-300 TOSHIBA
DO810 3BSE008510R1 ABB Digital Output
AI3281 AI3281-A-V001 TRICONEX Analog output module
BI01 BI01-A-V001 TRICONEX Digital quantity input template
330130-045-00-00 Bently Nevada 3300 XL Extension Cable
135489-03 Bently Nevada I/O module
DI3201 DI3201-A-V001 TRICONEX Analog output module
9200-01-01-10-00 Bently Nevada Two-Wire Velocity Seismoprobe Transducer
8521-LC-MT GE Logic Controller
8421-CC-PS GE CONTROLLER POWER CABLE
3511 TRICONEX 3511 Pulse Input Module
VT-HNC100-1-23 W-08-0-0 R900955334 Rexroth Digital Axis Controllers
705-1512-01 GE Processor module
T9451 ICS TRIPLEX AADvance Controllers series
SAN3-40 SAN3-40M DDK Servo Axis Controller
T9402 ICS TRIPLEX AADvance Controllers series
PR6423002-001-CN EPRO Eddy Current Sensor
PQM-T20-C-A GE POWER QUALITY METER
PDP800 ABB Profibus DP V0/V1/V2 Master Module
IS200EPSMG1ABB GE Exciter Power Supply Module
F35 HIMA Safety-Related Controller
F3 DIO 88 01 HIMA Safety-Related Controller
F3 AIO 84 01 HIMA Safety-Related Controller
DS200DCFBG1BNC GE Power Supply Board
CP451-51 YOKOGAWA Processor Module
A4H254-8F8T P0973JP Enterasys Network Switch
9200-06-02-10-00 Bently Nevada Two-Wire Transducer
8937-HN HONEYWELL Fiber Optic Extender Module
T9110 ICS TRIPLEX AADvance Processor Module
140CRA93200 Schneider RIO DROP ADAPTOR MODULE
CACR-02-TE1K YASKAWA
140DDI35300 Schneider DISCRETE INPUT MODULE
мы организуем фото на складе, чтобы подтвердить
чтобы вернуть их вам. Конечно, мы ответим на ваши озабоченности как можно скорее.
Reviews
There are no reviews yet.