Description
hardware flow control. It is an ideal choice in the field of industrial automation.
(1) Use STEP7V5.2 configuration software and enter Hardware Configure to complete S7-300 PLC hardware configuration;
(2) Select S7-315-2DP as the main station system, import the GSD (device database) file of NPBA-12 into the STEP7 programming environment, and configure the software
to configure NPBA-12 with S7-315-2DP as the main station. DP online, and select the PPO type to use. This design uses PPO4 to set the site network address. In the Profibus
structure of the variable frequency drive device, ABB frequency converters use the Profibus-DP communication module (NPBA-12) for data transmission, which is
mainly periodic: the host reads the input information from the slave station and sends the output information back to the slave station. ,
so it is necessary to call two system function blocks SFC14 and SFC15 in the PLC main program to read and write these data to achieve communication control to
the frequency converter;
(3) Create a data block in the main PLC program for data communication with the frequency converter; establish a variable table for observing the real-time
communication effect.
4 Inverter operation settings
After the frequency converter and PLC are connected to a network using Profibus-DP fieldbus, in addition to programming in the PLC automation system,
appropriate parameter settings must also be performed on each frequency converter.
After the communication cable is connected, start the inverter and complete the setting of the inverter communication parameters.
4.1 Basic settings
(1) 51.01—Module type, this parameter displays the module model detected by the transmission device. Its parameter value cannot be adjusted by the
user. If this parameter is not defined, communication between the module and the drive cannot be established.
(2) 51.02—This parameter selects the communication protocol, “0” selects the Profibus-DP communication protocol.
(3) 51.03—This parameter is Profibu
The PPO type selected by s connection, “3” is PPO4, but the PPO type on the inverter should be consistent with the PPO type configured on the PLC.
(4) 51.04—This parameter is used to define the device address number, that is, the site address of the frequency converter. Each device on the Profibus
connection must have a separate address. In this design, the two frequency converters are stations 2 and 3 respectively. [1]
4.2 Connection of process parameters
The process parameter interconnection completes the definition and connection of the corresponding parameters of the NPBA-12 dual-port RAM
connector and the frequency converter, including the connection from the master station (PLC) to the frequency converter and the connection from the frequency
converter to the master station (PLC). Set the following connection parameters on the frequency converter.
(1) PZD value sent from PLC to transmission inverter
PZD1—control word, such as start enable, stop, emergency stop and other control commands of the frequency converter;
PZD2—frequency setting value of the inverter.
(2) PZD value sent from the transmission inverter to the PLC
PZD1—status word, such as alarm, fault and other inverter operating status;
PZD2—actual speed value, current actual value, etc. of the frequency converter.
5 Conclusion
After the inverter control system adopts the Profibus-DP fieldbus control mode, the entire system not only has strong reliability and is easy to operate, but also can
be flexibly modified according to process needs. After this system was applied in Jigang Baode Color Plate Co., Ltd., it has been running well and has provided a successful
example for the future automation equipment (network communication of different manufacturers) of the head office.
New technology from Swiss ABB Group: Complete car charging in 15 seconds
This technology can charge a car in 15 seconds
The Swiss ABB Group has developed a new electric bus technology that can complete vehicle charging in 15 seconds . No other company”s battery technology can achieve this performance.
ABB has developed a technology called “Flash Charging” that allows an electric bus with 135 passengers to charge at charging points along the route. The charging point has a
charging power of 400 kilowatts and is located above the vehicle. The charging point is connected to a moving arm controlled by a laser and can charge the car battery in 15 seconds. Its
minimal design will help protect the urban environment and surrounding landscape.
The idea behind this design is to give the electric bus enough power to travel to the next charging station after one charge. The end of the line will allow for long periods of full charging
, with the car able to travel longer distances on a full charge. In addition to faster charging times, the system uses a carbon-emission-free solution called
TOSA to obtain electricity from clean hydroelectric power stations.
ABB initially plans to use this technology between Geneva Airport and the Palexpo International Convention and Exhibition Center. If the test is successful
, it will be deployed to public transportation systems. This is more cost effective and environmentally friendly.
ABB Executive Chief Technology Officer Claes Rytoft said: “With flash charging, we can trial a new generation of electric buses for large-scale transportation
in cities. This project will provide greater flexibility, cost-effectiveness and flexibility.” Paving the way for a lower public transport system while reducing pollution and noise.”
ABB OKYM175W22 10003130 CONTACTOR
NW-BM85C002 network modu
SCXI-1193 500 MHz Multiplexer/Matrix
NI GPIB-140B Bus Extender
PROSOFT MVI56-PDPS processor
MMS6120 Shaft vibration measurement module
MICROSET 104988-E03 Temperature control multi-scan
NEW LYD000A PLC Module
NEW LYA210A HITACHI Power module
LSU-113DG DEIF Load sharing units
K9203A Circulating fan K 9203A
HONEYWELL K4LCN-16 51403519-160 TDC 3000 Memory Processor
NYQUIST IOB-80 SERVO DRIVE I/O BOARD
IS220YDIAS1A Discrete Contact Input I/O module GE
IC754VSF12CTD 12 inch quick control panel
HONEYWELL FC-TSDI-16UNI safety management system module
Honeywell 900TBK-0101 TERMINAL BLOCK
Honeywell 900R04-0200 Hybrid Controller
Honeywell 900P01-0301 P01 Power Supply
Honeywell 900H02-0202 HC900 IO Card DO 24VDC 16CH
Honeywell 900G02-0202 CONTROLLER I/O MODULE
Honeywell 900C30-0460 ControlEdge HC900 Controller Base
Honeywell 900A01-0202 Analog Input Module
GPIB-140A Bus Extender
GF1-10TVD-100 Micro Innovation Touch Panel
FBM215 P0917TQ HART OUTPUT, 8 CHANNELS
F8652E SAFETY SYSTEM MODULE CPU
F8627 Ethernet Communication Module F 8627
DSQC604 3HAC12928-1 Power Supply
DS200LDCCH1AGA communications board
Triconex DO3401 Digital Output Module
Yokogawa CP451-10 Processor Module
CI867K01 3BSE043660R1 Communication Module
CE6050T06 Connection unit
PILLAR CB6687-2L PCB ASSEMBLY
DELTA TAU ACC-24E2 3-3397A-00-0000B200 Digital servo interface
ABB YT204001-KA/5 YPQ201A CPU-BOARD
MEN A201SR04 01A201S12 5880-0009 PCB M-MODULE
6637517A1 660-MISC-3311 Bailey circuit board
ALSTOM 502476L KCEU14201F51PEB controller
125840-02 3500/15 Low Voltage AC Power Input Module
9907-162 Digital governor of steam turbine
8446-1019 RP-3000 Remote Panel