Description
hardware flow control. It is an ideal choice in the field of industrial automation.
Nine Questions and Answers on Common Faults in ABB Industrial Robot Applications
Question 1: Under what circumstances do I need to back up my robot?
Answer: 1. After the new machine is powered on for the first time.
2. Before making any modifications.
3. After completing the modification.
4. If the robot is important, conduct it regularly once a week.
5. It is best to make a backup on a USB flash drive.
6. Delete old backups regularly to free up hard drive space.
Second question: What does the alarm message 10106 maintenance time reminder mean when the robot appears?
Answer: This is the intelligent periodic maintenance reminder of ABB robots.
Question 3: What should I do if the robot enters a system failure state when it is powered on?
Answer: 1. Restart the robot.
2. If it doesn”t work, check whether there is a more detailed alarm prompt on the teaching pendant and handle it.
3. Restart.
4. If it still cannot be lifted, try B startup.
5. If it still doesn’t work, try P startup.
6. If it still doesn’t work, try I startup (this will return the robot to factory settings, be careful).
Question 4: Can robot backup be shared by multiple robots?
Answer: No, for example, the backup of robot A can only be used for robot A, not robots B or C, because this will cause system failure.
Five questions: What files can be shared in the robot backup?
Answer: If the two robots are of the same model and configuration. You can share RAPID programs and EIO files, but they must be verified before they can be used normally.
Question 6: What is the mechanical origin of the robot? Where is the mechanical origin?
Answer: The six servo motors of the robot have a unique fixed mechanical origin. Incorrectly setting the mechanical origin of the robot will cause problems such
as limited movement or malfunction of the robot, the inability to walk in a straight line, etc., and serious damage to the robot.
Question 7: How to cancel the robot 50204 motion monitoring alarm?
Answer: 1. Modify the robot action monitoring parameters (control panel – action monitoring menu) to match the actual situation.
2. Use the AccSet command to reduce the robot”s acceleration.
3. Reduce the v_rot option in the speed data.
Eight questions: What should I do if the robot alarms “50296, SMB memory data difference” when it is powered on for the first time?
Answer: 1. Select calibration in the ABB main menu.
2. Click ROB_1 to enter the calibration screen and select SMB memory.
3. Select “Advanced” and click “Clear Control Cabinet Memory” after entering.
4. Click “Close” when finished, then click “Update”.
5. Select “The control cabinet or robot has been exchanged, and the control cabinet is updated using SMB memory data.”
Question 9: How to customize the speed of robot trajectory in the RAPID program?
Answer: 1. Select program data in the main menu of the teaching pendant.
2. After finding the data type Speeddata, click New.
3. Click on the initial value. The meanings of the four variables of Speeddata are: v_tcp represents the linear operating speed of the robot, v_rot
represents the rotational operating speed of the robot, v_leax represents the linear operating speed of the additional axis, v_reax represents the rotational
operating speed of the additional axis, if there is no additional axis, then No need to modify the two.
4. The customized data can be called in the RAPID program.
https://www.xmamazon.com
https://www.xmamazon.com
https://www.plcdcs.com/
www.module-plc.com/
https://www.ymgk.com
Schneider NW-BM85C002 Bridge multiplexer
SANYO DENKI P30B04010PCKST SERVO MOTOR
Motorola MVME147-013 32-bit microprocessor
MOTOROLA MVME2432-3 VME Processor Module MVME2432
Rexroth HMV01.1R-W0018-A-07-FNN1 Power control unit
HIMA F7553 984755302 PLC Coupling Module
HIMA F6217 984621702 8 fold analog input module
HIMA F3330 984333002 8-Channel Output Module
HIMA F3237 984323702 8 fold input module
Honeywell FC-TSGAS-1624 SAFE GAS-FLAME DET
Honeywell FC-PSU-UNI2450U V1.0 System power module
HIMA F6217 8-Channel Analog Input Module
WOODWARD EGCP-3 8406-113 Digital Control Interface Panel
Eaton XVS-440-10MPI-1-1AD Touch screen
8LSA35.DA030S000-3 B&R Synchronous motor
Sigmatek DNC115 DIGITAL OUTPUT MODUALE
Sigmatek DKL002 CPU Base
Sigmatek DDM163 Digital Conversion Module DDM 163
Alstom MAE99-04 PC BOARD RTD TERMINATION PANEL
KOLLMORGEN AKM42E-EKGNR-01 servomotor
ABB PCD235B101 3BHE032025R0101 Excitation controller PC D235
ABB CS513 3BSE000435R1 Communication Interface
FANUC A06B-6117-H104 Servo drive
FANUC A06B-6114-H209 Servo drive
Bently Nevada 135137-01 Position I/O Modul 3500/45
TRICONEX 9853-610
TRICONEX 9760-230 Termination panel
TRICONEX 9662-610 Standard termination panel
TRICONEX 9563-810 Digital output module
HONEYWELL 05704-A-0145 4-channel control card
TRICONEX 4351B Communication Module 4352AN 4352B
TRICONEX 3805E Analog Output Module 3806E
TRICONEX 3720 Analog Input Module 3721 3721C
TRICONEX 3704E INPUT MODULE 3703E 3700A 3708E
TRICONEX 3625 Digital 24VDC Output Module 3625A 3625C1
TRICONEX 3511 Pulse Input Module 3510
TRICONEX 3503E Digital Input Module 3505E
TRICONEX 3009 Enhanced main processor module 3009X
TRICONEX 3008 CPU Main Processor
Rockwell Allen-Bradley 1420-V2-ENT PowerMonitor 500 EtherNet/IP Power Meter
Lam Research 853-049542-173 Circuit board
Schneider 140DDM39000 Discrete I/O Module
Schneider 140DDI84100 Discrete Input Module
Schneider 140CRP93200 RIO Head-end Adaptor Module
Schneider 140CPU11303 512k CPU Module
Schneider 140CPS12420 Power Supply Module
Schneider 140CPS11420 Power Supply Module
Schneider 140ARI03010 Analog Input Module
Schneider 140CHS11000 Hot Standby Module
Schneider 140ACI03000 Class scale input module
8LSA35.E2060D000-0 B&R Synchronous motor
3IF661.9 B&R Input/output module
Reviews
There are no reviews yet.