hardware flow control. It is an ideal choice in the field of industrial automation.
We can perform simulation algorithms on Matlab.
3. The role of frequency converter
1. Frequency conversion energy saving
The energy saving of frequency converters is mainly reflected in the application of fans and water pumps. In order to ensure the reliability of production, various
production machines have a certain margin when they are designed to be equipped with power drives. When the motor cannot operate at full load, in addition to
meeting the power drive requirements, the excess torque increases the consumption of active power, resulting in a waste of electrical energy. The traditional speed
adjustment method for fans, pumps and other equipment is to adjust the air supply volume and water supply volume by adjusting the opening of the baffles and valves
at the inlet or outlet. The input power is large, and a large amount of energy is consumed in the interception process of the baffles and valves. middle. When using variable
frequency speed regulation, if the flow requirement is reduced, the requirement can be met by reducing the speed of the pump or fan.
The purpose of using a frequency converter for a motor is to regulate speed and reduce starting current. In order to produce variable voltage and frequency, the device first converts
the alternating current from the power supply into direct current (DC), a process called rectification. The scientific term for a device that converts direct current (DC) into alternating
current (AC) is “inverter”. Generally, an inverter converts DC power into an inverter power supply with a certain fixed frequency and voltage. The inverter with adjustable frequency and
adjustable voltage is called a frequency converter. The waveform output by the frequency converter is a simulated sine wave, which is mainly used for speed regulation of three-phase
asynchronous motors, also called a variable frequency speed regulator. For variable frequency inverters that are mainly used in instrumentation and testing equipment and
have higher waveform requirements, the waveforms need to be sorted and can output standard sine waves, which are called variable frequency power supplies. Generally, the price
of variable frequency power supply is 15-20 times that of the inverter. Since the main device in the inverter equipment that produces changing voltage or frequency is called “inverter”,
the product itself is named “inverter”, that is: inverter.
Frequency conversion does not save power everywhere, and there are many occasions where using frequency conversion does not necessarily save power. As an electronic circuit,
the frequency converter itself also consumes power (about 3-5% of the rated power). A 1.5-horsepower air conditioner consumes 20-30W of electricity, which is equivalent to a
continuous light. It is a fact that the inverter runs at power frequency and has a power-saving function. But his prerequisite is:
https://www.xmamazon.com
https://www.xmamazon.com
https://www.plcdcs.com/
www.module-plc.com/
https://www.ymgk.com
136188-02 BENTLY vibration monitoring system
106M1081-01 Temperature monitor BENTLY
3500/92-02-01-01 Transient Data Interface BENTLY
3500/42M 140734-02 Temperature monitor BENTLY
3500/50 288062-02 Temperature monitor BENTLY
125680-01 BENTLY overspeed protection module
3500/22M 288055-01 Temperature monitor BENTLY
3500/05-01-01-00-00-00 Transient Data Interface BENTLY
3500/20 125760-01 Temperature monitor BENTLY
3500/32 125712-01 BENTLY overspeed protection module
3500/50M 288062-02 Temperature monitor BENTLY
3701/55-01-01 BENTLY vibration monitoring system
3500/42M 176449-02 BENTLY vibration monitoring system
3500/93 135799-01 BENTLY overspeed protection module
3500/53 133396-01 BENTLY vibration monitoring system
3500/32 125712-01 BENTLY vibration monitoring system
125680-01 BENTLY overspeed protection module
3500/92 136180-01 Temperature monitor BENTLY
3500/42-02-00 BENTLY overspeed protection module
140471-01 BENTLY vibration monitoring system
3500/15-05-05-00 Temperature monitor BENTLY
125680-01 Transient Data Interface BENTLY
3500/22M 146031-01 BENTLY vibration monitoring system
3500/22-01-01 BENTLY overspeed protection module
1900/65A-00-00-01-00-00 Temperature monitor BENTLY
3500/22-01-01-01 BENTLY4 Channel Relay Module
3500/32 125720-01 BENTLY overspeed protection module
3500/05-01-01-00-00-00 Temperature monitor BENTLY
146031-01 BENTLY vibration monitoring system
3500/94 145988-01 BENTLY4 Channel Relay Module
3500/33 149986-01 BENTLY overspeed protection module
3500/42M 140734-02 BENTLY overspeed protection module
3500/15 114M5335-01 Temperature monitor BENTLY
3500/92 136180-01 BENTLY vibration monitoring system
3500/77M 176449-07 BENTLY vibration monitoring system
135799-01 Transient Data Interface BENTLY
3500/05-01-01-01-00-00 Transient Data Interface BENTLY
128276-01 BENTLY overspeed protection module
3500/15 114M5335-01 BENTLY vibration monitoring system
3500/42M 176449-02 Transient Data Interface BENTLY
1900/65A-00-02-02-00-01 BENTLY overspeed protection module
3500/92-02-01-01 BENTLY overspeed protection module
3500/92-02-01-00 Temperature monitor BENTLY
3500/40-03-00 176449-01 Temperature monitor BENTLY