Nine Questions and Answers on Common Faults in ABB Industrial Robot Applications
Question 1: Under what circumstances do I need to back up my robot?
Answer: 1. After the new machine is powered on for the first time.
2. Before making any modifications.
3. After completing the modification.
4. If the robot is important, conduct it regularly once a week.
5. It is best to make a backup on a USB flash drive.
6. Delete old backups regularly to free up hard drive space.
Second question: What does the alarm message 10106 maintenance time reminder mean when the robot appears?
Answer: This is the intelligent periodic maintenance reminder of ABB robots.
Question 3: What should I do if the robot enters a system failure state when it is powered on?
Answer: 1. Restart the robot.
2. If it doesn”t work, check whether there is a more detailed alarm prompt on the teaching pendant and handle it.
3. Restart.
4. If it still cannot be lifted, try B startup.
5. If it still doesn’t work, try P startup.
6. If it still doesn’t work, try I startup (this will return the robot to factory settings, be careful).
Question 4: Can robot backup be shared by multiple robots?
Answer: No, for example, the backup of robot A can only be used for robot A, not robots B or C, because this will cause system failure.
Five questions: What files can be shared in the robot backup?
Answer: If the two robots are of the same model and configuration. You can share RAPID programs and EIO files, but they must be verified before they can be used normally.
Question 6: What is the mechanical origin of the robot? Where is the mechanical origin?
Answer: The six servo motors of the robot have a unique fixed mechanical origin. Incorrectly setting the mechanical origin of the robot will cause problems such
as limited movement or malfunction of the robot, the inability to walk in a straight line, etc., and serious damage to the robot.
Question 7: How to cancel the robot 50204 motion monitoring alarm?
Answer: 1. Modify the robot action monitoring parameters (control panel – action monitoring menu) to match the actual situation.
2. Use the AccSet command to reduce the robot”s acceleration.
3. Reduce the v_rot option in the speed data.
Eight questions: What should I do if the robot alarms “50296, SMB memory data difference” when it is powered on for the first time?
Answer: 1. Select calibration in the ABB main menu.
2. Click ROB_1 to enter the calibration screen and select SMB memory.
3. Select “Advanced” and click “Clear Control Cabinet Memory” after entering.
4. Click “Close” when finished, then click “Update”.
5. Select “The control cabinet or robot has been exchanged, and the control cabinet is updated using SMB memory data.”
Question 9: How to customize the speed of robot trajectory in the RAPID program?
Answer: 1. Select program data in the main menu of the teaching pendant.
2. After finding the data type Speeddata, click New.
3. Click on the initial value. The meanings of the four variables of Speeddata are: v_tcp represents the linear operating speed of the robot, v_rot
represents the rotational operating speed of the robot, v_leax represents the linear operating speed of the additional axis, v_reax represents the rotational
operating speed of the additional axis, if there is no additional axis, then No need to modify the two.
4. The customized data can be called in the RAPID program.
https://www.xmamazon.com
https://www.xmamazon.com
https://www.plcdcs.com/
www.module-plc.com/
https://www.ymgk.com
TVB6002-1/IMC 1308-644857-12 1381-644857-16 TEL BOADR
TVB3101-1/ISC 1381-644957-16 1308-644957-12 TEL BOARD
TVB-1202-1/ANET 1381-647980-12 TEL board
XV-440-12TSB-1-10 EATON Touch panel
SLIO-02 ROLLS ROYCE NETWORK CONTROLLER
45C992 RELIANCE Analog Input Module
MVI69-MCM PROSOFT Modbus Master/Slave Network Interface Module
LD800HSE-3BDH000320R02 ABB Fieldbus Linking Device
KP3000 ABB Silicon controlled module
KP2500 ABB Silicon controlled module
3100-MCM PROSOFT Modbus communication interface
1785T-PMPP-1700 Rockwell touch screen
5SHY35L4503 ABB High voltage IGCT driver module
SCXI-1313A NI Terminal Block
SC753A-001-01 Pacific Scientific Servo Drive
SAC-SW220/EB ORMEC SERVOWIRE DRIVE
S22460-SRS KOLLMORGEN Servo driven drive
PXI-6713 NI PXI Analog Output Module
PXI-6602 NI Counter/Timer Module
PMC-234 RAMIX CompactFlash Module
PCIE-5565-PIORC GE Reflective Memory node card
ZETA6104 Parker Indexer/Drive
KJ1710X1-BA1 EMERSON Fibre Channel Switch
H1127.0101 Rolls-Royce Marine Controller
FSA80 DANAHER Servo drive
FAW05-5R0 TDK AC-DC Power Supplies
F7133 HIMA 4 Channel Power Distribution Module
F6217 HIMA 8-Channel Analog Input Module
F3330 HIMA 8-Channel Output Module
F3322 HIMA Digital Output Module
F3236 HIMA 16-Channel Digital Input Module
EC10-2416BRA EMERSON Frequency converter module
DSQC1018 ABB Computer
DKC11.1-040-7-FW Rexroth DKC Drive Controllers
CR-GENO-M6400R3 DALSA Teledyne Industrial Camera
CLS204 WATLOW ANAFAZE Temperature control unit
CACR-02-KIBA YASKAWA SERVO DRIVER
C2RPS-PSM ENTERASYS Power Supply
AT-MR126F ALLIED TELESIS TRANSCEIVER MICRO REPEATER
VFD_6713_V2 HONEYWELL main control panel
330103-00-06-10-02-05CN Bently Nevada 3300 XL 8 mm Proximity Probes
AT-MX40FST-05 ALLIED TELESIS International Pty Ltd
ACN CS METSO high-performance multi-function
3500/40M 140734-01 Bently Nevada Proximitor Monitor I/O Module
70085-1010-411 13A AI-TEK Speed sensor
8602-FT-ST GE PAC8000 Field terminal, standard
ZETA6104 PARKER Indexer/Drive
1C31179G01 Westinghouse Remote Input Output Master Attachment Unit
VT-HNC100-1-23W-08-P-0 Rexroth VT-HNC100 Digital Axis Controllers
VRDM 39750 LWB Berger Lahr stepper motor
VFD4A8MS21ANSAA Delta Variable frequency Drive (VFD)
VE6041F01C1 EMERSON Smart Switch
UMI-7764 NI Universal Motion Interface
TVD1.3-15-03 Rexroth TVD Supply Modules
T2550L80F32ELINSERIAL FOXBORO unit controller
Reviews
There are no reviews yet.