Description
hardware flow control. It is an ideal choice in the field of industrial automation.
3.2 Upgrading of regulators and control systems
For the upgrade of the regulator, the original excitation control system cabinet structure is retained, and the entire system is upgraded by upgrading the board card.
Among them, the CoB main board, MUB measurement board, F10 input and output board, and LCP local control panel were replaced with the PEC800 controller,
CCM measurement control interface board, CIo comprehensive input and output board, and ECT excitation system control terminal in the Unitrol6800 system respectively.
For the upgrade of the power cabinet, since the power of the excitation system will not change during the transformation, the N-1 redundant configuration of the five
UNL3300 rectifier bridges in the original system has not been changed, but the control and measurement parts of the rectifier
bridge have been upgraded. And the fan circuit and power control part of the rectifier bridge have been upgraded. Among them, the signal interface board (PsI) was
changed to the rectifier bridge signal interface board (CsI), the circuit breaker of the rectifier bridge panel was changed from CDP to CCP, and the rectifier bridge control
interface board (CIN) was changed to the rectifier bridge control board (CCI).
For the upgrade of the demagnetization cabinet, the switch control part was mainly upgraded. By adding a CIo board to the switch cabinet and installing a special
power distributor and relay to control the demagnetization switch, the original PsI board was removed. Secondly, in the transformation of the current detection part,
the Hall element in the Unitrol5000 system was replaced by the current relay of the Unitrol6800 system.
For the upgrade of the excitation current measurement part, the rectifier side Hall element of the rectifier bridge was replaced with an AC side CT. Relying on the linearity of the
CT, the current sharing coefficient of the excitation system was increased to 0.98, so that the role of the rectifier bridge can be fully exerted in the system. .
For the upgrade of the fan power supply circuit of the rectifier cabinet, each power cabinet can independently control the power supply of the fans in the
cabinet to avoid the problem that if the power circuit relay fails in the original system, all the fans will not work.
3.3Unitrol6800 functional logic configuration points
The Unitrol6800 system adds PT slow-blow judgment logic, and defines the actions of PT slow-blow as alarm and channel switching. The system PT
slow-blow logic pressure difference is 2% to ensure sufficient sensitivity. Since some external reasons will cause the sequential increase or decrease of magnetic
commands, a special increase or decrease magnetic contact adhesion judgment logic has been added to effectively lock out external causes. At the same
time, it can
avoid the jitter of the relay on the increase or decrease magnetic circuit and ensure the stability of the circuit. The excitation temperature detection is used to
alarm in the system, but it cannot control the system tripping. The tripping intermediate relays K291 and K292 use high-power (≥5w) relays to avoid
the problem of tripping of the excitation system
due to signal interference.
4 Problems discovered during the transformation and their solutions
After upgrading the excitation system from Unitrol5000 to Unitrol6800, since the partition between the regulator cabinets of the original excitation switch
cabinet was removed and the mounting backplate of the regulator was moved forward, the hot air from the excitation switch cabinet will enter the excitation regulator
cabinet, causing the cabinet to be damaged. The internal temperature rises, and sometimes the temperature can even reach 45°C. In order to avoid problems caused
by high temperatures, partitions were added to reduce the temperature inside the switch cabinet and control the
temperature to 30°C.
During the maintenance process, if the grounding carbon brush of the generator is removed, it is easy to cause the rotor grounding relay isoLR275 to
malfunction. Therefore, during maintenance, the power supply of the grounding relay will be disconnected and the large shaft in the magnetic cabinet will be short-circuited.
5 Conclusion
Through the transformation of the excitation system, our company not only meets the needs of increasing the generator capacity, but also
eliminates the safety hazards of ARCnet failure or flat cable damage in the excitation system of the unit. It can find the fault point during maintenance
and prevent the unit from non-stop. event. The new board used in the new excitation system has modular characteristics, which can make online maintenance more
convenient, and because the boards use trigger pulse generation communication and optical fiber redundant communication, the stability of
information transmission is ensured. Avoid communication failures and damage to pulse lines.
https://www.xmamazon.com
https://www.xmamazon.com
https://www.plcdcs.com/
www.module-plc.com/
https://www.ymgk.com
3BSE028140R0065 ABB Tension controller
3BHE037649R0101 ABB Industrial control module
3BHE025335R0121 ABB CP Power electronic module
3BHE019633R0101 ABB Power system module
3BHE042816R0101 ABB System power module
3BHE032025R1101 ABB Central processing unit
3BHE025541R0101 ABB Robot system spare parts
3BHE025541R0101 ABB Processor unit
NPCT-01C ABB Channel digital input
NMTU-21C 3BSE017429R1 ABB Thermal resistance power module
NF93A-2 HESG440280R2 ABB Power electronic module
NDCU-12C NDCU-12CK ABB Analog input subroutine
MSR04X1 ABB DCS power module
MC91 HESG440588R4 HESG112714/B ABB Pulse amplifier plate
3BHL000986P7000 ABB Processor end module
SG13433241070 ABB Modular redundant controller
GJR5252300R3101 ABB Communication control panel
3BHE046836R0101 ABB Controller system in stock
3BHE022294R0103 ABB Central processing unit
3BHE022294R0103 ABB Processor unit
PPD113-B03-23-111615 ABB Central processing unit
PP835 3BSE042234R1 Touch screen
ABB PP825A 3BSE042240R3 Touch screen
PP815A 3BSE042239R2 ABB Man-machine interface
PP836 3BSE043449R501 ABB Man-machine interface
PP820 3BSE042243R1 ABB Function key panel
TRICONEX 3805E Signal input/output module
PP826 3BSE042244R1 ABB Function key panel
SCHNEIDER TSXCUSBMBP PLC control system
RELIANCE ELECTRIC WR-D4008 Digital input module
RELIANCE ELECTRIC S-D4043 Distributed control system
RELIANCE ELECTRIC S-D4041 Programmable control system
RELIANCE ELECTRIC S-D4012 Channel analog input
RELIANCE ELECTRIC S-D4007 Programmable control system
RELIANCE ELECTRIC S-D4006 Multifunctional controller
NI SCXI-1520 strain input module
NI SCXI-1127 Multiplexer switch module
NI SCXI-1125 Voltage input module
NI SCXI-1000 SCXI Chassis NI
LAETUS LLS570-05 Laser scanner
GE WESDAC D20ME Digital input module
GE WES5302-150 I/O communication modules
GE WES5162 frame
GE WES5302-111 Distributed control system
GE WES5162-9101 Frame interface module
GE WES5123-2600 Analog output module
WES5123-1200 GE Analog input module
WES5120 5120-1106 GE Serial communication module
WES5120 5120-1506 GE Field controller master unit
PRG-MODEM GE 8-channel digital input
WES13-3 GE Pressure regulating device main control board
DL-1200/RTU GE Digital input module New spot
GE D20 MIC 10BASE-T I/O moduleFresh spot
Framework of GE D20 EME Fresh spot
GE D20 EME 10BASE-T I/O unit module New spot
D20 EME GE Analog input module Fresh spot
XV-440-10TVB-1-13-1 EATON Man-machine interface New spot
PU512V2 3BUR001401R1 ABB Digital input card New spot
1TGE120010R1300 ABB Digital input card Fresh spot
REG216 Robot drive power supply ABB
216NG63 Analog input board ABB
S-D4041 Analog input module RELIANCE ELECTRIC
S-D4043 PLC controller RELIANCE ELECTRIC
WR-D4008 Analog input module RELIANCE ELECTRIC