Description
hardware flow control. It is an ideal choice in the field of industrial automation.
In the formula, a is the design acceleration/deceleration value: s is the current actual position value of the
elevator: V2 is the maximum speed of the elevator at this position.
Considering that the lifting system needs to enter the parking track at a low crawling speed when entering the
end of the stroke to avoid equipment damage caused by large mechanical impact, therefore, when there are still
1~5m away from the parking position, the lifting speed is limited to 0.5m/ below s.
Since the instantaneous speed before parking is very low, the position accuracy of the system”s parking can
be relatively improved, which is particularly important when the auxiliary shaft is lifted.
2.2 Design and implementation of security protection functions
Mines have particularly strict requirements on safety and reliability of hoist control systems [5]. While ensuring high
reliability of electrical control equipment, the control system also sets up multiple protections in key links where failures
may occur, and detects the actions and feedback signals of these protection devices in real time.
First of all, monitoring the operating status of the elevator is the top priority in the safety protection
function of the elevator control system. In the control system, the operating speed and position of the
motor are monitored at all times, and the current position and speed values are compared with the system”s
designed speed and position curve. Once it is found that the
actual operating speed of the hoist exceeds the designed speed value, immediately Issue an emergency
stop command and strictly ensure that the lifting speed is within the safe monitoring range during the entire
lifting process. At the same time, position detection switches are
arranged at several locations in the wellbore, and these position detection switches correspond to specific
position values and corresponding speed values. When the elevator passes these switches, if it is found through
encoder detection that the actual speed value and position deviate from the values corresponding to the position
detection switch, the control system will also judge that it is in a fault state
and immediately implement an emergency stop.
In order to determine whether the encoder connected to the main shaft of the elevator drum is normal,
two other encoders are installed on the elevator. In this way, the position and speed detection values
of the three encoders are always compared. Once it is found that the deviation between the detection
value of one encoder and the detection value of the other two encoders exceeds the allowable range,
the control system will immediately consider it to have entered a fault state and implement an emergency stop. Protective action.
3 Conclusion
The efficient and safe operation of main well equipment is an important guarantee for its function.
In the application of mine hoist, the 800xA system designed speed curve, self-correction, various
self-diagnosis and protection functions according to the specific process characteristics of the main
shaft mine hoist, which has achieved good results in practical applications.
https://www.xmamazon.com
https://www.xmamazon.com
https://www.plcdcs.com/
www.module-plc.com/
https://www.ymgk.com
05701-A-0361 Backplane Serial communication controller and monitor
810-800081-022 LAM Circuit board module
05074-A-0122 05704-A-0121 05704-A-0131 Relay interface card
810-066590-004 LAM Circuit board module
T8403C Trusted TMR 24Vdc digital input module
05701-A-0325 DC input card
T9110 AADvance controller
T9451 AADvance controller Controller module
T9402 AADvance controller
T8311 Trusted TMR expander Interface
T8151B Trusted ® Communication Interface Adapter
T8310 Trusted TMR expander Interface
05704-A-0145 Four-channel controller card 4-20 MA input
GE IS215VCMIH2BB IS200VCMIH2BCC Mark VI System board components
E1740A Agilent Time interval analyzer
GE IS215VCMIH2CA IS200VCMIH2CAA VME communication card
E1406A Agilent Time interval analyzer
05704-A-0144 Four channel control card catalytic input
FBM233 P0926GX FBM233 Field device system integration module
IS420UCSBH1A Mark VIe series UCSB controller
DDC779BE02 3BHE006805R0002 Control panel and control system
MMS6120 Dual channel bearing vibration measurement module MMS 6120
24765-02-01 Housing expansion sensor assembly
CI526 3BSE006085R1 Interface Module
3BSE005831R1 PM632 Processor Unit
3BSE004773R1 CS513K02 MasterBus 300E communication interface
PU512V1 3BSE004736R1 Real Time Accelerator (RTA) Module
3BSE004726R1 DSTD197 Connection Unit 8 ch, 120V
3BSE004723R1 DSTD190 Connection Unit 32 Ch
3BSE004382R1 DSRF185 ABB
DSDX180 3BSE003859R1 Digital In / Out Module
3BSE003832R1 SC510 Submodule Carrier without CPU
3BSE003829R1 CI532V04 AC410 » Communication Modules
3BSE003827R1 CI532V02 MODBUS Interface, 2 ch
SA167 3BSE003390R1 Power Supply Unit AC 115V / DC
SA168 3BSE003389R1 Power Supply Unit
07KR51-230VAC 1SBP260511R1001 Controller Basic Unit
07KP93 GJR5253200R1161 Communication Processor
ABB 07KP90 GJR5251000R0303 Communications Module
07KP53 1SBP260162R1001 MODBUS Coupler (07KP53)
07DC92 GJR5252200R0101 Configurable Digital I/O Module
07DC91 GJR5251400R0202 Digital I/O module
07CR41-c12 1SBP260020R1001 Advant Controller Basic Unit
07CR41 1SBP260020R1001 07CR41 Advant Controller Basic Unit – 24VDC
07AI91 GJR5251600R0202 Analog I/O, module
07AC91 GJR5252300R0101 ABB Advant OCS Analog I/O Unit
HIEE320693R0001 NU8976A Power module
HIER466665R0099 NU8976A99 Excitation module