Description
hardware flow control. It is an ideal choice in the field of industrial automation.
user experience
Secondly, if power system engineers are to consider the convenience and speed of using the product in the future, operability needs to be improved while ensuring stability.
This requires a simple self-service system and an operation interface with good visual effects that can meet the needs of users. Some operating habits and other aspects
* cut costs
Furthermore, since there are many nodes in the power system, the same product needs to be deployed on many nodes. Then when the quantity of required products increases,
cost issues will inevitably be involved. How to solve the research and development, construction and installation of products and better reduce operating expenses is also a major issue that ABB needs to consider.
Implementation of communication between Omron vision system and ABB industrial robot
introduction
In modern production processes, vision systems are often used to measure and identify products, and then the results are transmitted to industrial robots for work
through communications . In this process, communication settings are very important. This article analyzes the communication implementation process between the Omron
FH-L550 vision system and ABB industrial robots. The main task is to enable the vision system to provide data detection results for ABB industrial robots, and the industrial robots
perform related operations based on the data results. This article mainly discusses the entire process of visual system communication transmission implementation.
1Ethernet-based communication settings in vision software
The main communication methods of Omron FH-L550 vision system controller are as follows [2], namely: parallel communication, PLCLINK communication, Ethernet
communication, EtherCAT communication, and protocol-free communication. These five communication methods have their own characteristics in the communication process.
In modern equipment, Ethernet communication
(Ethernet communication) is the most common, so this article uses the Ethernet communication method as an example to analyze and explain.
First, select the “Tools” option in the main interface, select the “System Settings” menu (Figure 1), after entering the “System Settings” menu, click the “Startup Settings” option,
and select the “Communication Module” tab (Figure 2 ), after completing the above settings, return to the main interface to save the settings (Figure 3). Finally, select the function
menu to perform system restart settings, and wait for the system to complete the restart before proceeding to the next step.
After the system restarts, click the “System Settings” menu again and select the “Ethernet (No Protocol (UDP))” option (Figure 4). In this option, there will be parameter settings
such as IP address and port. What needs to be noted here are the two IP address parameters. The parameters in “Address Setting 2” need to be filled in. The information that needs
to be filled in includes the IP address of the vision controller, subnet mask, default gateway and DNS server.
In the port number setting of “Input/Output Settings” at the bottom of the menu, set the port number for data input with the sensor controller. Note that the port number should
be the same as the host side, and finally complete the settings and corresponding data saving work.
2ABB industrial robot communication settings
First, configure the WAN port IP address for the ABB industrial robot. Select the control panel in the teach pendant, then select configuration, then select communication in
the theme, click IPSetting, set the IP information and click “Change” to save the IP information.
Next, use the SocketCreate robot command to create a new socket using the streaming protocol TCP/IP and assign it to the corresponding variable (Figure 5). Then
use the SocketConnect command to connect the socket to the remote computer. After the communication connection is completed, it is necessary to send and receive
information from the visual system. To send information, use the SocketSend instruction to send data instructions to the remote computer. After the vision system collects
information and makes judgments, the industrial robot system will receive data from the remote computer. The data reception is completed using the
SocketReceive instruction. This instruction stores the data in the corresponding string variable while receiving the data. Useful information needs to be extracted from the
received data information, which requires StrPart to find the specified character position instruction, extract the data at the specified position from the string, and assign the
result to a new string variable. Finally, when the socket connection is not in use, use SocketCloSe to close it.
https://www.xmamazon.com
https://www.xmamazon.com
https://www.plcdcs.com/
www.module-plc.com/
https://www.ymgk.com
VOLVO PENTA 3888244 I-RP REMOTE CONTROL PANEL
VODAVI LDK-300 RGU INTERNAL RING GENERATOR UNIT
VICKERS EEA-PAM-119-A-10 POWER AMPLIFIER BOARD WITH CURRENT CONTROL
UZUSHIO ELECTRIC UKB-3-50E-A CONTROL PANEL
UZISHIO ELECTRIC UGS-11-USY11 SYNCHRONIZE UNIT
UNI-SAFE ELECTRONICS SALINOMETER SL6005 CONTROL PANEL
UNI-SAFE ELECTRONICS SALINOMETER SL6000 CONTROL PANEL
TYCO SAFETY-THORN SECURITY T1204A2 FIRE SAFETY CONTROL PANEL
TWINDISC EC075-1023645 CONTROL PANEL
TERASAKI TFE-2000-XAS-EXTENSION ALARM SYSTEM ENGINE CONTROL ROOM PANEL
TERASAKI MODEL-GAC-16MC EIN-102 GENETATING PLANT MANAGEMENT DEVICE
SULZER 2T-38-84 112-045-584-200 LAMP CONTROL PANEL
STN ATLAS MARINE ELECTRONICS-EURO MARINE GROUP C6115 ZM-401 CENTRAL MODULE
STN ATLAS MARINE ELECTRONICS S-396-262 BRAKE CONTROL UNIT
STN ATLAS MARINE ELECTRONICS BAT 415-B 271-135-562 OPERATOR PANEL
STN ATLAS ELEKTRONIK-LYNGSO MARINE SAM-401 DUAL SYSTEM BUS MODULE
STN ATLAS ELEKTRONIK C4338 VSM-401 VALVE CONTROL MODULE
STN ATLAS ELEKTRONIK C4338 RM-401 CONTROL MODULE
STN ATLAS ELEKTRONIK C4338 DSM-401 DIESEL CONTROL MODULE
STEIN SOHN VISTA AUTOMATION TYPE-070640-F503006A-XAS-EXTENSION-ALARM-SYSTEM CONTROL PANEL
SPEICH GENOVA UCP32 WIPERS CONTROL UNIT
SPEICH GENOVA UCP-34-9324 WIPERS CONTROL PANEL
SPEICH GENOVA UC34-T-9323 BOX PANEL
SPEICH GENOVA CJB220-25703-VER2 BOX PANEL
SOREN T.LYNGSO DIESEL MANOEUVRING SYSTEM 900 CONTROL PANEL
SICK ABSOLUTE ENCODER AG100-4124BC100000-1 DRIVER SSI
SENSOR-TECHNIK WIEDEMANN GMBH ESX2-4 32216-2311 STW ECU ELECTRONIC CONTROL MODULE
SEATEX MRU-E-JB1 BOX MODULE
SCHOTTEL MASTERSTICK MD-02 JOYSTICK & CONTROL PANEL
SCHOTTEL MASTERSTICK ES-660255-PORTABLE-DESK JOYSTICK CONTROL PANEL
SCANTROL WI-101 MODULE
EATON XVS-440-10MPI-1-10
EATON MP3010
EATON XV-440-10TVB-1-20
EATON XVS-440-10MPI-1-1U
EATON MPB2-TP
EATON XV-440-10TVB-1-10
EATON XVS-440-57MPI-1-10
SCANA MAR-EL N-3886 DALEN MPS110 PRINT-E CONTROLLER MODULE
SCANA MAR-EL MAC-102S-2192 UNIT
SAM ELECTRONICS-LYNGSO MARINE PFM-2200 MODULE
SAM ELECTRONICS-LYNGSO MARINE PFM-2200 MODULE
SAM ELECTRONICS-LYNGSO MARINE IFM-2200 MODULE
SAM ELECTRONICS-LYNGSO MARINE BXM-2200 MODULE
SAM ELECTRONICS-LYNGSO MARINE BSM-2200 MODULE
SAM ELECTRONICS-LYNGSO MARINE BRM-2200 MODULE
SAM ELECTRONICS ESG-40M-ELECTRONIC SPEED GOVERNOR PANEL
SAM ELECTRONICS C6115 RM-401 CONTROL MODULE
SAM ELECTRONICS C-6115 BAT 271-132-228-C BATTERY CONTROL PANEL
SAM ELECTRONICS BMS-40M-BRIDGE-MANOEUVRING-SYSTEM PANEL
SAM ELECTRONICS BMS-40M-BRIDGE-MANOEUVRING-SYSTEM GEAMOT ECR PANEL
SAIA PCD2.M120 CONTROL DEVICE
SAIA PCD2.M110 CONTROL DEVICE
SAIA PCD-2-M110 CONTROL DEVICE
Reviews
There are no reviews yet.