Description
hardware flow control. It is an ideal choice in the field of industrial automation.
Nine Questions and Answers on Common Faults in ABB Industrial Robot Applications
Question 1: Under what circumstances do I need to back up my robot?
Answer: 1. After the new machine is powered on for the first time.
2. Before making any modifications.
3. After completing the modification.
4. If the robot is important, conduct it regularly once a week.
5. It is best to make a backup on a USB flash drive.
6. Delete old backups regularly to free up hard drive space.
Second question: What does the alarm message 10106 maintenance time reminder mean when the robot appears?
Answer: This is the intelligent periodic maintenance reminder of ABB robots.
Question 3: What should I do if the robot enters a system failure state when it is powered on?
Answer: 1. Restart the robot.
2. If it doesn”t work, check whether there is a more detailed alarm prompt on the teaching pendant and handle it.
3. Restart.
4. If it still cannot be lifted, try B startup.
5. If it still doesn’t work, try P startup.
6. If it still doesn’t work, try I startup (this will return the robot to factory settings, be careful).
Question 4: Can robot backup be shared by multiple robots?
Answer: No, for example, the backup of robot A can only be used for robot A, not robots B or C, because this will cause system failure.
Five questions: What files can be shared in the robot backup?
Answer: If the two robots are of the same model and configuration. You can share RAPID programs and EIO files, but they must be verified before they can be used normally.
Question 6: What is the mechanical origin of the robot? Where is the mechanical origin?
Answer: The six servo motors of the robot have a unique fixed mechanical origin. Incorrectly setting the mechanical origin of the robot will cause problems such
as limited movement or malfunction of the robot, the inability to walk in a straight line, etc., and serious damage to the robot.
Question 7: How to cancel the robot 50204 motion monitoring alarm?
Answer: 1. Modify the robot action monitoring parameters (control panel – action monitoring menu) to match the actual situation.
2. Use the AccSet command to reduce the robot”s acceleration.
3. Reduce the v_rot option in the speed data.
Eight questions: What should I do if the robot alarms “50296, SMB memory data difference” when it is powered on for the first time?
Answer: 1. Select calibration in the ABB main menu.
2. Click ROB_1 to enter the calibration screen and select SMB memory.
3. Select “Advanced” and click “Clear Control Cabinet Memory” after entering.
4. Click “Close” when finished, then click “Update”.
5. Select “The control cabinet or robot has been exchanged, and the control cabinet is updated using SMB memory data.”
Question 9: How to customize the speed of robot trajectory in the RAPID program?
Answer: 1. Select program data in the main menu of the teaching pendant.
2. After finding the data type Speeddata, click New.
3. Click on the initial value. The meanings of the four variables of Speeddata are: v_tcp represents the linear operating speed of the robot, v_rot
represents the rotational operating speed of the robot, v_leax represents the linear operating speed of the additional axis, v_reax represents the rotational
operating speed of the additional axis, if there is no additional axis, then No need to modify the two.
4. The customized data can be called in the RAPID program.
https://www.xmamazon.com
https://www.xmamazon.com
https://www.plcdcs.com/
www.module-plc.com/
https://www.ymgk.com
AUTO-MASKIN DCU-305-R3 ENGINE CONTROL UNIT
AUTO MASKIN RK-60-REV.3 ENGINE CONTROLLER MODULE
AUTO MASKIN MK-6-75260 ENGINE CONTROLLER MODULE
ARISTON NORWAY TCU-SURVEYOR CONTROL UNIT
ARISTON NORWAY 3920 CONTROL UNIT
AQUA SIGNAL 3429-101-L002 NAVIGATION LIGHT CONTROL PANEL
ANQING MARINE ELECTRIC FTD-I APM MOTOR CONTROL DEVICE
ALFA LAVAL VCU-160 VISCOSITY CONTROL PANEL
ALFA LAVAL SCOP45-DX485G OP-45 SATT CONTROL PANEL
ABB IOD86-MEM MEMORY BOARD MODULE
ABB FDC86-CONT CONTROLLER MODULE
2FRANCE MARINE STEM CONTROL M1-MN0C-10016 CONTROL MODULE
UZUSHIO ELECTRIC UMP02H-PCB CIRCUIT BOARD
UZUSHIO ELECTRIC UMP02A-PCB CIRCUIT BOARD
UZUSHIO ELECTRIC UIOO1-PCB CIRCUIT BOARD
UZUSHIO ELECTRIC UHS01-PCB CIRCUIT BOARD
UZUSHIO ELECTRIC UDO02-PCB CIRCUIT BOARD
UZUSHIO ELECTRIC UD101-PCB CIRCUIT BOARD
UZUSHIO ELECTRIC UAI02-PCB CIRCUIT BOARD
ULSTEIN BRATTVAAG AS 222-651-PLC2000C.PCB CIRCUIT BOARD
TERASAKI ESM-1152-K-014-1-001A MODULE CARD APPEARANCE
ROLLS-ROYCE WRC1021B-BRATTVAAG CIRCUIT BOARD
ROLLS-ROYCE ULSTEIN TENFJORD AS 5880-PC1019 CIRCUIT-BOARD
ROLLS-ROYCE ULSTEIN TENFJORD AS 5880-PC1018 CIRCUIT-BOARD
ROLLS-ROYCE ULSTEIN TENFJORD AS 5880-PC1011 CIRCUIT-BOARD
ROLLS-ROYCE ULSTEIN PROPELLER AS PFI1038-PULS-FREQUENCY-INTERFACE-CARD CIRCUIT BOARD
ROLLS-ROYCE ULSTEIN PROPELLER AS PDM1040-POWER-DISTRIBUTION-&-MONITOR-CARD CIRCUIT BOARD
ROLLS-ROYCE ULSTEIN PROPELLER AS PCC1030C-PANEL-CONTROLLER-CARD CIRCUIT BOARD
ROLLS-ROYCE ULSTEIN PROPELLER AS DIO1037A-DIGITAL-IO-INTERFACE-CARD CIRCUIT BOARD
ROLLS-ROYCE ULSTEIN PROPELLER AS DC0034A-PROPORTIONAL-VALVE-DRIVER-CARD CIRCUIT BOARD
ROLLS-ROYCE ULSTEIN PROPELLER AS DC0034A-PROPORTIONAL-VALVE-DRIVER CIRCUIT BOARD
ROLLS-ROYCE ULSTEIN PROPELLER AS AIO1036A-ANALOG-IO-INTERFACE-CARD CIRCUIT BOARD
ROLLS-ROYCE ULSTEIN MARINE PLC1002A CIRCUIT BOARD
ROLLS-ROYCE ULSTEIN MARINE PLC1001A CIRCUIT BOARD
ROLLS-ROYCE ULSTEIN MARINE ELECTRONICS TDT-30014A-PCB CIRCUIT BOARD
ROLLS-ROYCE ULSTEIN MARINE DC0033A-STEPPER-MOTOR-DRIVER-891026 CIRCUIT BOARD
ROLLS-ROYCE ULSTEIN BRATTVAAG TDT-30014 CIRCUIT BOARD
ROLLS-ROYCE ULSTEIN BRATTVAAG TDC-30009A CIRCUIT BOARD
ROLLS-ROYCE ULSTEIN BRATTVAAG 222-652C-CAN2002C.PCB CIRCUIT BOARD
ROLLS-ROYCE TYPE-MEA-403-ITEM-92814 CIRCUIT BOARD
ROLLS-ROYCE TYPE-DC-0015D-PANEL-INTERFACE-1987-03-24 CIRCUIT BOARD
ROLLS-ROYCE TYPE-BLS1034A BACKUP LAMP SWITCH CARD
ROLLS-ROYCE TYPE-222-653-PLC-2001-PCB CIRCUIT BOARD
ROLLS-ROYCE TYPE-222-651-PLC-2000-PCB CIRCUIT BOARD
ROLLS-ROYCE RBP40019-KA CIRCUIT BOARD
ROLLS-ROYCE PTP40010B CIRCUIT BOARD
ROLLS-ROYCE PLC1002A CIRCUIT BOARD
ROLLS-ROYCE PLC-2001B.PCB-22-JAN-2001-N4A-16701-C4904-TYPE-194VQ-PANEL-INTERFACE CIRCUIT BOARD
ROLLS-ROYCE PIC1041-PANEL-INTERFACE-CARD CIRCUIT BOARD
ROLLS-ROYCE OLC-40009L-A-ITEM-91899 CIRCUIT BOARD
Reviews
There are no reviews yet.