Description
hardware flow control. It is an ideal choice in the field of industrial automation.
3.3 Design of computer control software
This type of control software runs on the computer and is mainly used for remote operation. It has multiple functions such as parameter setting, control operation,
data collection and storage, status detection and alarm, etc. Its interface is shown in Figure 3.
The system shown in Figure 3 contains four independent control channels, and the software can manage and configure the test plan based on parameter information.
That is: for each test plan, you can configure different test plans and set different test parameters through the “Configuration” operation. You can also create new plans,
save and modify plans, open existing plans, and delete plans.
The software also sets up quick operations, which can quickly start and stop work according to the channel configuration, and can detect the working status of
each channel in real time.
3.4 Design of touch screen software
The touch screen software is mainly used for local control and runs in the touch screen controller. While the computer control software has similar functions,
it also has the setting function of local control priority or remote control priority. The default is remote control priority. The login interface and test operation interface
are shown in Figure 4 and Figure 5 respectively.
3.5 Design of PLC software
As the core of this control system, PLC is mainly responsible for the following aspects:
Responsible for sending corresponding control parameters and instructions to the frequency converter, and at the same time obtaining the status
of the transmission system through the ProfibusDP bus protocol.
Communicates with the touch screen through serial communication, responds to local control instructions, and feeds back system status to the touch screen as a slave
computer for local control. Programming between the touch screen and PLC is performed by directly accessing the PLC variable address.
It communicates with the remote control computer through the OPC[5] communication method based on the external network, responds to the remote control instructions
, and feeds back the system status to the remote control computer as the remote control slave. Programming between the remote control program and the PLC is
performed by accessing the PLC variable name.
Process the emergency signal and control the inverter to slow down and unload according to the default parameters.
Figure 4 Login interface
Figure 5 Test interface
3.6 Frequency converter settings
In general, the inverter will be equipped with an optional operation panel. Before using the local or remote control program to operate the inverter,
you must first perform the basic settings of the inverter, as follows:
Switch the control mode to local control and set the inverter address according to the inverter user manual.
Set the inverter for remote control and select the communication mode.
Set the frequency converter to use an encoder, and connect the motor for self-test matching operation.
Set the speed control mode of the inverter, such as speed control or torque control.
After completing the basic parameter settings, switch to the remote control state and wait for remote control.
4 Conclusion
This system implements a universal belt-turning mechanism that utilizes frequency conversion control technology. You can use the local touch screen to
control the inverter to control the motor
rotation and obtain corresponding feedback, or you can use remote control to control the inverter to achieve the same control effect as the local touch screen,
even in view of the computer function The richness allows you to obtain more system information and set more control states. In addition to local touch screen
control and remote control, the overall structure of this system can also be split into the most basic transmission structure to complete the control, that is,
the motor is controlled directly through the
control panel of the frequency converter to achieve the most basic and direct control. Therefore, this system can be used as a basic framework structure to
meet all similar control requirements, and obtain different levels of usage requirements through different levels of hardware configuration, which has universal reference significance.
https://www.xmamazon.com
https://www.xmamazon.com
https://www.plcdcs.com/
www.module-plc.com/
https://www.ymgk.com
WOODWARD 8440-1301
WOODWARD 8440-2088
WOODWARD 8440-1936
WOODWARD 8440-2150
WOODWARD 8440-1947
WOODWARD 8440-1809
WOODWARD 8440-2152
WOODWARD 8440-1936
WOODWARD 8440-1884
WOODWARD 8440-1868
WOODWARD 8440-1952
WOODWARD 8440-1878
8440-2222 – Woodward’s easYgen
WOODWARD 8200-203- ProTech 203 overspeed protection
WOODWARD 8200-508
WOODWARD 8200-314 – Digital Driver Board
Woodward Rotary actuators | VBR Turbine Partners 8200-188
WOODWARD 8200-1204 – LINKnet HT AIO
WOODWARD 8200-224 – Servo Position Controller
WOODWARD Governor 8200-150
WOODWARD 8200-226
Woodward 9907-205 MSLC/DSLC Hand Held Programmer
WOODWARD 8200-507 Steam Turbine Digital Governor
WOODWARD 8200-1300
WOODWARD 8200-1302 – 505D Digital Governor Turbine Control
Woodward 505D Digital Speed Governing Turbine Controller 8200-1502
WOODWARD 8200-1508
WOODWARD 8200-1350 Flex500- Turbines
WOODWARD 8200-1301-505D Digital Governor Turbine Control
WOODWARD 8200-1310 Turbine Digital Control
WOODWARD 5464-050 Digital Microprocessor Controller
5466-258 | 5466-258 Woodward | Simplex Discrete I/O Module
WOODWARD 5464-674 Digital Microprocessor Controller
WOODWARD 5464-738
WOODWARD microgrid digital control 5464-552
WOODWARD 5464-843
WOODWARD 5464-331 Digital Microprocessor Controller
WOODWARD 5464-333- Thermocouple input module available in stock
WOODWARD 5464-011
WOODWARD 5464-365A
WOODWARD 5464-365 Module digital speed sensor
WOODWARD 5464-330
WOODWARD 5464-218
Best WOODWARD 5464-643 discrete input (48 channels)
WOODWARD 5464-654
WOODWARD 5464-850
WOODWARD 5464-545
WOODWARD 5464-414
“WOODWARD 9905-003”
“WOODWARD EASYGEN-1000”
“WOODWARD EASYGEN-320”
“WOODWARD ESAYGEN-1000”
“WOODWARD 9907-018”
“WOODWARD 9907-163”
woodward 9907-163
Reviews
There are no reviews yet.