Description
hardware flow control. It is an ideal choice in the field of industrial automation.
In the formula, a is the design acceleration/deceleration value: s is the current actual position value of the
elevator: V2 is the maximum speed of the elevator at this position.
Considering that the lifting system needs to enter the parking track at a low crawling speed when entering the
end of the stroke to avoid equipment damage caused by large mechanical impact, therefore, when there are still
1~5m away from the parking position, the lifting speed is limited to 0.5m/ below s.
Since the instantaneous speed before parking is very low, the position accuracy of the system”s parking can
be relatively improved, which is particularly important when the auxiliary shaft is lifted.
2.2 Design and implementation of security protection functions
Mines have particularly strict requirements on safety and reliability of hoist control systems [5]. While ensuring high
reliability of electrical control equipment, the control system also sets up multiple protections in key links where failures
may occur, and detects the actions and feedback signals of these protection devices in real time.
First of all, monitoring the operating status of the elevator is the top priority in the safety protection
function of the elevator control system. In the control system, the operating speed and position of the
motor are monitored at all times, and the current position and speed values are compared with the system”s
designed speed and position curve. Once it is found that the
actual operating speed of the hoist exceeds the designed speed value, immediately Issue an emergency
stop command and strictly ensure that the lifting speed is within the safe monitoring range during the entire
lifting process. At the same time, position detection switches are
arranged at several locations in the wellbore, and these position detection switches correspond to specific
position values and corresponding speed values. When the elevator passes these switches, if it is found through
encoder detection that the actual speed value and position deviate from the values corresponding to the position
detection switch, the control system will also judge that it is in a fault state
and immediately implement an emergency stop.
In order to determine whether the encoder connected to the main shaft of the elevator drum is normal,
two other encoders are installed on the elevator. In this way, the position and speed detection values
of the three encoders are always compared. Once it is found that the deviation between the detection
value of one encoder and the detection value of the other two encoders exceeds the allowable range,
the control system will immediately consider it to have entered a fault state and implement an emergency stop. Protective action.
3 Conclusion
The efficient and safe operation of main well equipment is an important guarantee for its function.
In the application of mine hoist, the 800xA system designed speed curve, self-correction, various
self-diagnosis and protection functions according to the specific process characteristics of the main
shaft mine hoist, which has achieved good results in practical applications.
https://www.xmamazon.com
https://www.xmamazon.com
https://www.plcdcs.com/
www.module-plc.com/
https://www.ymgk.com
FOXBORO RH916XG FBM201 TERMINAL ASSEMBLY
ALLEN BRADLEY 80165-698-51-R PC BOARD
RELIANCE 0-57210-31 Stabilizer plate
ABB T-1521Z Multifunctional link
ABB R-2521Z Multifunctional link
VT-HNC100-2-30/P-I-00/G02 R901134616
FOXBORO P0916QD FBM218/237 Redundant Adapter
FOXBORO P0916DE CABLE
ABB LST200 Ultrasonic level transmitter
FBM215/218 P0917XV COMPRESSION TERMINATION ASSEMBLY
DS200DCFBG1BLC GE Power Supply Board
ALLEN BRADLEY 192646 PC BOARD
ALLEN BRADLEY 185558 Driver isolation circuit board
ALLEN BRADLEY 154958 PC BOARD
Rockwell 148540 NODE ADAPTER BOARD
ALLEN BRADLEY 74102-462-53 Ac driver board
Rockwell A-B 1336S-EN6 Ac driver
A-B 1336-L5 Control interface board
TRICONEX 4000098-510 Cable assembly 10 ft
WEIDMULLER 915917/67 Terminal Adapter
146031-01 Bently Nevada Transient Data Interface I/O Module
MTL 8724-CA-PS module power supply carrier
Allen-Bradley 1756-OB16E Discrete output module
1452-25M Prosoft Connector
842E-CM-MIP3BA Encoder
Foxboro P0926JM 8 Position Modular Baseplate Stock
P0922XS Foxboro TSC Power Cable
FOXBORO RH916DD controller
AO920N 3KDE175533L9200 S900 I/O system
FOXBORO RH916XG FBM 201 TERMINAL ASSEMBLY
AO920B 3KDE175532L9200 S900 I/O System
DO930N 3BDS014114 S900 I/O system Digital Output
DO910S 3KDE175321L9100 S900 I/O system
DO910N 3KDE175323L9100 S900 I/O system
PM862K02 3BSE081636R1 AC800M PM862 controller
PM863K01 3BSE088381R1 AC800M PM863 controller
PM866AK01 3BSE076939R1 AC800M PM866/PM866A controller
PM867K02 3BSE081638R1 AC800M PM867 controller
PM864AK02 3BSE018164R1 AC800M PM864A controller
PM851AK01 3BSE066485R1 AC800M PM851/PM851A controller
PM856AK01 3BSE066490R1 AC800M PM856A controller
SA920N 3BDH000600R1 S900 I/O system
SA920B 3BDH000601R1 S900 I/O system
DX910S 3KDE175311L9100 S900 I/O system
DX910N 3KDE175313L9100 S900 I/O System
DX910B 3KDE175312L9100 S900 I/O System
DP910S 3KDE175361L9100 S900 I/O system
DP910N 3KDE175363L9100 S900 I/O system
DP910B 3KDE175362L9100 S900 I/O system
PM858K02 3BSE082896R1 AC800M PM858 controller unit