Description
hardware flow control. It is an ideal choice in the field of industrial automation.
In the formula, a is the design acceleration/deceleration value: s is the current actual position value of the
elevator: V2 is the maximum speed of the elevator at this position.
Considering that the lifting system needs to enter the parking track at a low crawling speed when entering the
end of the stroke to avoid equipment damage caused by large mechanical impact, therefore, when there are still
1~5m away from the parking position, the lifting speed is limited to 0.5m/ below s.
Since the instantaneous speed before parking is very low, the position accuracy of the system”s parking can
be relatively improved, which is particularly important when the auxiliary shaft is lifted.
2.2 Design and implementation of security protection functions
Mines have particularly strict requirements on safety and reliability of hoist control systems [5]. While ensuring high
reliability of electrical control equipment, the control system also sets up multiple protections in key links where failures
may occur, and detects the actions and feedback signals of these protection devices in real time.
First of all, monitoring the operating status of the elevator is the top priority in the safety protection
function of the elevator control system. In the control system, the operating speed and position of the
motor are monitored at all times, and the current position and speed values are compared with the system”s
designed speed and position curve. Once it is found that the
actual operating speed of the hoist exceeds the designed speed value, immediately Issue an emergency
stop command and strictly ensure that the lifting speed is within the safe monitoring range during the entire
lifting process. At the same time, position detection switches are
arranged at several locations in the wellbore, and these position detection switches correspond to specific
position values and corresponding speed values. When the elevator passes these switches, if it is found through
encoder detection that the actual speed value and position deviate from the values corresponding to the position
detection switch, the control system will also judge that it is in a fault state
and immediately implement an emergency stop.
In order to determine whether the encoder connected to the main shaft of the elevator drum is normal,
two other encoders are installed on the elevator. In this way, the position and speed detection values
of the three encoders are always compared. Once it is found that the deviation between the detection
value of one encoder and the detection value of the other two encoders exceeds the allowable range,
the control system will immediately consider it to have entered a fault state and implement an emergency stop. Protective action.
3 Conclusion
The efficient and safe operation of main well equipment is an important guarantee for its function.
In the application of mine hoist, the 800xA system designed speed curve, self-correction, various
self-diagnosis and protection functions according to the specific process characteristics of the main
shaft mine hoist, which has achieved good results in practical applications.
https://www.xmamazon.com
https://www.xmamazon.com
https://www.plcdcs.com/
www.module-plc.com/
https://www.ymgk.com
169-10C-120169-10C-120 GE relay
140DRA84000 Schneider Discrete quantity output module
140DDI35300 Schneider Discrete input module
140ACI03000 Schneider Analog input module
139-NSF-V-TC GE Heat capacity meter
106M7607-01 Bently Nevada relay
106M1079-01 Bently Nevada Power module
88UB01A ABB module
70EA05a-E ABB Analog input element
70EA01b-E HESG447038R1 ABB Controller module
70BV01C-ES HESG447260R1 ABB driver
70BK03B-ES HESG447271R2 ABB convertor
70BA01C-S HESG447260R2 ABB Processor power module
ABB module 70AA02B-E HESG447388R1 filter
61C22B Reliance Electric Intelligent temperature controller
8LSA35.E2060D000-0 B&R position detection sensor
8C-PCNT02 HONEYWELL Input/output module
07KT98-H4 ABB Basic module Ethernet
07KT93 ABB controller
07AI91 ABB Analog input/output module
07AC91D ABB Remote module
5SHY3545L0009 ABB IGCT Series
3PS465.9 B&R Bus module
3IF661.9 B&R Interface module
3IF060 B&R Programmable interface processor
3HAC044168-001 ABB Robot joint
3HAC031977.2017 ABB 3 hac031977.2017
3HAC029818-00110 DSQC663 ABB Driving device
3HAC025527 ABB microprocessor
3HAC025338-006 ABB Main servo drive unit
3HAC025097-001 ABB Computer unit
3HAC14549-312A ABB Output module
3BHL000396P0001 ABB condenser
3BHE024577R0101 ABB Inverter module
3BHE014070R0101 ABB Power converter
3AXD50000007342 ABB Power semiconductor module
3ASC25H208 ABB Pulse transformer
3ASC25H203 ABB Adapter module
VE3004 Controller module
UTX1010 processor
UTX-1000A Power converter
TVOC-2-240-1SFA664001R1001 Arc monitor
TRAFOTEK-CHK0520
TERADYNE-A1004-00003-398-723-00 Numeric arithmetic operation
TAP-210DG-3 Watt sensor
SV1-10483156 Servo valve
SNAP-IDC5D I/O digital input modules are
SIEMENS-6SE7022-6EC61-Z Dc governor
SIEMENS-6FC5210-0DF31-2AA0 Electronic control equipment
SIEMENS-6FC5203-0AF02-0AA0 operator panel
SIEMENS-6FC5103-0AB03-0AA2 Front operating panel
SIEMENS-6ES7416-3ES06-0AB0 Central processing unit
Reviews