Description
5 Fieldbus network layer
5.1 mfb (master field bus) bus
The mfb bus is a field LAN bus and is connected between mp200, mp90, s400i/o, OPC (small control station) and the transmission system.
The mfb communication bus uses coaxial cables and twisted pairs. It connects the ci520/ci525/ci526 communication interface module and the
dstc452 modem. The ends of each twisted pair must be isolated, and the shielding layer of one end must be grounded. The communication of mfb
The rate is 375kb/s, its resistance is 75 ohms, and its hardware configuration is shown in Figure 3. The relevant system information of mfb is obtained from
the engineering station. The general order is time, information model, code, task number, sequence number, and data. It mainly displays the following states.
Code 20: cpu communication interface contact lost
Code 21: fatal hardware failure
Code 39: device/staTIon ok
Code 72: device/statIon address ok
Code 120: Process failure
Code-1: Execution error
Code -4: System error
Code -5: Minor system site error
Code-6: Communication failure
Code-9: Catastrophic bus failure
Code -10: Redundant cable interrupted
5.2 af100 (advant field)/mb90 (master bus) bus
The purpose of AF100/MB90 is to provide communication between multiple APC sites or between APC sites and ABB industrial system equipment. MB90 supports two different types of communication,
data processing and information sending. The data set is dynamic data. Use To monitor and control a certain processing process, this process uses service information for parameterization, program installation,
and diagnosis. AF100/MB90 is a high-performance regional bus capable of connecting up to 79 APC sites. The mb90 has a maximum length of 300 meters, and if equipped with appropriate signal cables and signal repeaters,
and long-distance configurations between individual transmission devices are available, up to 2000 meters. Technical characteristics of the bus
(1) Communication rate 1.5mbit/s
(2) Attenuation bus length <300m, proliferation delay <2000m
(3) Telegram length 2, 4, 6, 8,…32 bytes of user data.
(4) Identification code (telegraph code) range 1…4000
(5) Cycle time 2, 4, 8, 16, 32, 64, 128…2048 or 4096ms
af100/mb90 relies on a centralized bus manager. The bus manager functions are relatively complex and have many requirements.
For example, apc sites cannot be used as bus managers because they do not contain bus manager functions. To make communication between APCs via
AF100/MB90 possible, each solution (standalone and embedded) can be used to arrange the bus master of AF100/MB90. When the APCs start executing
their applications, the bus master must be operable, otherwise the data set function block within the apc branch will enter an error state when the locally
configured data set is not acknowledged by the bus manager within the specified time limit. , if the system has only apc site and no masterpiece is connected to mb90 or ac450 and af100, an independent bus manager should be installed.
The communication between ABB DCS and the transmission system (such as acv700/dcv700) is realized by relying on the drrtra (drive trans mi t) element and drrec (drive reciver) element shown in Figure 4 .
The drrtra (drive transmit) element is used to pass a given data set to the abb drive controller and select the control word and command word signal of the drive signal.
The definition of the control word and command word signal is given in the application drive software description. The drrtr element can generate different types of periodic
messages supported by the drive communication protocol. The destination of the signal is selected by the drive signal. The drrtr element can also write parameters. In the normal phase, the overload of drrtr can be detected.
The drrec (drive reciver) element is used to receive signals and control word values from the abb drive controller. The definitions of these signals are given in the application drive software description. The drrec element is just periodic information supported
by the drive connection protocol. The receiving data source is selected by determining the drive signal and signal index through the element input parameters. The drrec element also has access to parameters, and overloads of drrec can be detected during configuration.
xv-102-b5-35-tqr-10-plc Eaton touch screen
XV-102-H4-57TVRL-10 Eaton touch screen
XVC-601-GTI-15-DPM-V1-000 Micro innovative touch screen
XP-702-D0-84TSI-10 Micro innovative touch screen
XN-KO/14 Industrial control panel
XV-460-84TVB-1-1O Industrial control panel
XV-430-12TSB-1-10-PLC Eaton touch screen
XN-KO/4 Imported from Eaton’s original factory
XV-102-D6-70TWRC-10 Imported from Eaton’s original factory
MC2-440-10TVB-1-2A Micro innovative touch screen
XVH-340-57MPI-1-13 Micro innovative touch screen
XV-102-B6-35TQR-10-PLC Eaton touch screen
XN-PLC-CANOPEN Eaton touch screen
XV-102-D6-70TWRC-10 Eaton touch screen
XVS-440-10MPI-1-10 Imported from Eaton’s original factory
XV-102-D6-57TVRC-10 Industrial control panel
XV-303-15-C00-A00-1B Eaton touch screen
XV-102-D8-70TWRC-10 Industrial control panel
XVS-440-10MPI-1-10 Imported from Eaton’s original factory
MH2-340-57BAS-1-1D Micro innovative touch screen
XV-102-D4-70TWRG-10 Micro innovative touch screen
XVS-460-15MPI-1-10 Eaton touch screen
MC2-440-12TSB-1-50 Industrial control panel
XN-2DO-R-NC Industrial control panel
XVS-440-57MPI-1-10 Eaton touch screen
XN-KO/17 Industrial control panel
XV-440-10TVB-1-13-1 Eaton touch screen
XV-440-12TSB-1-10 Full range touch screen EATON
XV-440-12TSB-1-10-PLC-SET Imported from Eaton’s original factory
XVS-440-10MPI-1-1U Micro innovative touch screen
XVC-601-GTI-10-V1-010 Imported from Eaton’s original factory
XV-442-57CQB-1-1U Industrial control panel
XV-303-10-C00-A00-1C Eaton touch screen
XP-DVI-12T-20 Micro innovative touch screen
XVS-460-57MPI-1-10 Micro innovative touch screen
WEW-35/2 Micro innovative touch screen
MH2-330-57MPI-1-10 Imported from Eaton’s original factory
XV-102-A4-35MQR-10 Eaton touch screen
XV-440-12TSB-1-10-PLC-SET Eaton touch screen
XV-440-10TVB-1-1AI Micro innovative touch screen
XN-2DO-R-NC Full range touch screen EATON
XVS-430-10MPI-1-10 Imported from Eaton’s original factory
XV-102-B4-35TQR-10 Micro innovative touch screen
XVS-460-15MPI-1-10 Full range touch screen EATON
XP-702-D0-84TSI-10 Industrial control panel
XP-702-F0-84TSIK-10 Imported from Eaton’s original factory
XV-152-D0-84TVR-10 Eaton touch screen
XV-102-B5-35TQR-10-PLC Industrial control panel
XV-102-D8-70TWRC-10 Full range touch screen EATON
XN-KO/13 Eaton touch screen
XN-QV/5 Eaton touch screen
MC2-442-57CQB-1-2O Eaton touch screen
XV-230-57CNN-1-13-1 Imported from Eaton’s original factory
XVS-440-10MPI-1-1U Full range touch screen EATON
XVS-460-15MPI-1-10 Micro innovative touch screen
XV-440-10TVB-1-50 Industrial control panel
XN-2AI-THERMO-PI Industrial control panel
XVC-601-GTI-12-DPS-V1-000 Eaton touch screen
XV-102-H4-70TWRL-10 Micro innovative touch screen
XV-102-D0-57TVR-10 Full range touch screen EATON
XV-303-10-C00-A00-1B Micro innovative touch screen
OS-FLASH-A1-S Industrial control panel
XVC-101-C192K-K82 Micro innovative touch screen
XV-102-B5-35TQR-10-PLC Industrial control panel
XV-DVI-GTR-12-000 Industrial control panel
XV-102-BE-35TQRC-10 Micro innovative touch screen
XN-S3T-SBC Full range touch screen EATON
XN-KO/12 Full range touch screen EATON
XV-102-D4-57TVR-10 Full range touch screen EATON
XV-430-10TVB-1-10 Eaton touch screen
XV-152-D6-10TVR-10 Eaton touch screen
XN-B6S-SBCSBC Imported from Eaton’s original factory
MH2-340-57CAN-1-50 Eaton touch screen
XV-102-D4-70TWR-10 Full range touch screen EATON
XVS-440-57MPI-1-10 Micro innovative touch screen
Reviews
There are no reviews yet.