Description
hardware flow control. It is an ideal choice in the field of industrial automation.
In the formula, a is the design acceleration/deceleration value: s is the current actual position value of the
elevator: V2 is the maximum speed of the elevator at this position.
Considering that the lifting system needs to enter the parking track at a low crawling speed when entering the
end of the stroke to avoid equipment damage caused by large mechanical impact, therefore, when there are still
1~5m away from the parking position, the lifting speed is limited to 0.5m/ below s.
Since the instantaneous speed before parking is very low, the position accuracy of the system”s parking can
be relatively improved, which is particularly important when the auxiliary shaft is lifted.
2.2 Design and implementation of security protection functions
Mines have particularly strict requirements on safety and reliability of hoist control systems [5]. While ensuring high
reliability of electrical control equipment, the control system also sets up multiple protections in key links where failures
may occur, and detects the actions and feedback signals of these protection devices in real time.
First of all, monitoring the operating status of the elevator is the top priority in the safety protection
function of the elevator control system. In the control system, the operating speed and position of the
motor are monitored at all times, and the current position and speed values are compared with the system”s
designed speed and position curve. Once it is found that the
actual operating speed of the hoist exceeds the designed speed value, immediately Issue an emergency
stop command and strictly ensure that the lifting speed is within the safe monitoring range during the entire
lifting process. At the same time, position detection switches are
arranged at several locations in the wellbore, and these position detection switches correspond to specific
position values and corresponding speed values. When the elevator passes these switches, if it is found through
encoder detection that the actual speed value and position deviate from the values corresponding to the position
detection switch, the control system will also judge that it is in a fault state
and immediately implement an emergency stop.
In order to determine whether the encoder connected to the main shaft of the elevator drum is normal,
two other encoders are installed on the elevator. In this way, the position and speed detection values
of the three encoders are always compared. Once it is found that the deviation between the detection
value of one encoder and the detection value of the other two encoders exceeds the allowable range,
the control system will immediately consider it to have entered a fault state and implement an emergency stop. Protective action.
3 Conclusion
The efficient and safe operation of main well equipment is an important guarantee for its function.
In the application of mine hoist, the 800xA system designed speed curve, self-correction, various
self-diagnosis and protection functions according to the specific process characteristics of the main
shaft mine hoist, which has achieved good results in practical applications.
https://www.xmamazon.com
https://www.xmamazon.com
https://www.plcdcs.com/
www.module-plc.com/
https://www.ymgk.com
3BHE022333R0101 GATE DRIVER BOARD ABB
HP 5517B Agilent laser head/Sensor
140SAI94000S SCHNEIDER 8 Enter the analog safety input module
810-046015-010 PCB board
3BHE024415R0101 GVC714A101 GATE DRIVER BOARD ABB
SC-PCMX01 51307195-175 RTU2020 Controller
3500/25 149369-01 Enhanced Keyphasor Module
PR6424/010-130+CON011 probe and preprocessor
1786-RPFM control network modularization
TSXDSZ08R5 TSX Miniature 8 output relay
TSX3721001 PLC configuration
TSXDEZ12D2 12 Discrete input
TSXDMZ28DR 28 Input/output
1756-TBNH Terminal board or RTB module
Sensor PR6423/01R-010-CN+CON021
1756-PA75R/A Redundant power module
Sensor PR6423/01R-010-CN+CON021
PS8310 TRICONEX Power module Provides 120 volts AC
3721N TRICONEX 3721N Analog input module
VM600 RLC16 relay card
VM600 CPUM Modular CPU card
VM600 MPC4SIL Mechanical protection card
VM600 XIO16T Input/output module
VM600 MPC4 mechanical protection card
VM600 IRC4 intelligent relay card
VM600 IOCR2 input/output card
VM600 IOCN input/output card
VM600 IOC8T input/output card
VM600 IOC4T input/output card
VM600 AMC8 Analog monitoring card
VM600 CPUR rack controller and communication interface card
VM600 XMV16 Vibration status monitoring module
VM600 XMC16 Combustion status monitoring module
VM600 ABE056 Ultra-thin rack
VM600 ASPS auxiliary sensor power supply
PLX82- IP-PNC controller gateway
DRP-240-24 MEAN WELL rail type power supply
6181P-17TPXPH performance computer
C7024E1001 Flame detector
IC3600STKK1 temperature control panel
IC3600STKJ1C thermocouple amplifier card
VE4003S2B3 S series traditional input/output
1756-EN3TR Communication bridge module
DS200TBCAG1AAB analog input/output terminal board
AIM0006 2RCA021397A0001K Main Control Board
20AC030A0AYNANC0 PowerFlex 70 drive
20AC072A0AYNANC0 AC drive
22A-D2P3N104 PowerFlex 4 Adjustable frequency AC drive
2711-K5A5L11 PanelView 550 Terminal
TBU810 Terminal basic unit ABB
CPM810 Universal processor module ABB
IC694TBB032 Terminal board components
7CP476-020.9 CPU B&R