Description
5 Fieldbus network layer
5.1 mfb (master field bus) bus
The mfb bus is a field LAN bus and is connected between mp200, mp90, s400i/o, OPC (small control station) and the transmission system.
The mfb communication bus uses coaxial cables and twisted pairs. It connects the ci520/ci525/ci526 communication interface module and the
dstc452 modem. The ends of each twisted pair must be isolated, and the shielding layer of one end must be grounded. The communication of mfb
The rate is 375kb/s, its resistance is 75 ohms, and its hardware configuration is shown in Figure 3. The relevant system information of mfb is obtained from
the engineering station. The general order is time, information model, code, task number, sequence number, and data. It mainly displays the following states.
Code 20: cpu communication interface contact lost
Code 21: fatal hardware failure
Code 39: device/staTIon ok
Code 72: device/statIon address ok
Code 120: Process failure
Code-1: Execution error
Code -4: System error
Code -5: Minor system site error
Code-6: Communication failure
Code-9: Catastrophic bus failure
Code -10: Redundant cable interrupted
5.2 af100 (advant field)/mb90 (master bus) bus
The purpose of AF100/MB90 is to provide communication between multiple APC sites or between APC sites and ABB industrial system equipment. MB90 supports two different types of communication,
data processing and information sending. The data set is dynamic data. Use To monitor and control a certain processing process, this process uses service information for parameterization, program installation,
and diagnosis. AF100/MB90 is a high-performance regional bus capable of connecting up to 79 APC sites. The mb90 has a maximum length of 300 meters, and if equipped with appropriate signal cables and signal repeaters,
and long-distance configurations between individual transmission devices are available, up to 2000 meters. Technical characteristics of the bus
(1) Communication rate 1.5mbit/s
(2) Attenuation bus length <300m, proliferation delay <2000m
(3) Telegram length 2, 4, 6, 8,…32 bytes of user data.
(4) Identification code (telegraph code) range 1…4000
(5) Cycle time 2, 4, 8, 16, 32, 64, 128…2048 or 4096ms
af100/mb90 relies on a centralized bus manager. The bus manager functions are relatively complex and have many requirements.
For example, apc sites cannot be used as bus managers because they do not contain bus manager functions. To make communication between APCs via
AF100/MB90 possible, each solution (standalone and embedded) can be used to arrange the bus master of AF100/MB90. When the APCs start executing
their applications, the bus master must be operable, otherwise the data set function block within the apc branch will enter an error state when the locally
configured data set is not acknowledged by the bus manager within the specified time limit. , if the system has only apc site and no masterpiece is connected to mb90 or ac450 and af100, an independent bus manager should be installed.
The communication between ABB DCS and the transmission system (such as acv700/dcv700) is realized by relying on the drrtra (drive trans mi t) element and drrec (drive reciver) element shown in Figure 4 .
The drrtra (drive transmit) element is used to pass a given data set to the abb drive controller and select the control word and command word signal of the drive signal.
The definition of the control word and command word signal is given in the application drive software description. The drrtr element can generate different types of periodic
messages supported by the drive communication protocol. The destination of the signal is selected by the drive signal. The drrtr element can also write parameters. In the normal phase, the overload of drrtr can be detected.
The drrec (drive reciver) element is used to receive signals and control word values from the abb drive controller. The definitions of these signals are given in the application drive software description. The drrec element is just periodic information supported
by the drive connection protocol. The receiving data source is selected by determining the drive signal and signal index through the element input parameters. The drrec element also has access to parameters, and overloads of drrec can be detected during configuration.
Excitation system ABB module IEMMU21
Excitation system ABB module IEMMU21
Excitation system ABB module IEMMU21
Excitation system ABB module IEMMU21
Excitation system ABB module IEMMU12
Excitation system ABB module IEMMU11
Excitation system ABB module IEMMU04
Excitation system ABB module IEMMU02
Excitation system ABB module IEMMU01
Excitation system ABB module IEMMU01
Excitation system ABB module IEFAN90
Excitation system ABB module IEFAN02
Excitation system ABB module IEFAN01
Excitation system ABB module IDPG 940128102
Excitation system ABB module ICST08A9
Excitation system ABB module ICSK20F1
Excitation system ABB module ICSE08B5
Excitation system ABB module ICSE08B5
Excitation system ABB module ICSA04B5
Excitation system ABB module IBA 940143201
Excitation system ABB module IAM MODULE
Excitation system ABB module HVC-02B 3HNA024966-00103
Excitation system ABB module HVC-02 3HNA011999-001
Excitation system ABB module HVC-01 2A 3HNA008270-001
Excitation system ABB module HPC800K02
Excitation system ABB module HIES207036R003
Excitation system ABB module HIER466665R0099
Excitation system ABB module HIER466665R0099
Excitation system ABB module HIER464920P0001
Excitation system ABB module HIEE451220R1 HI903897-310/49 RTA108BE
Excitation system ABB module HIEE451116R0001 FM9925A-E
Excitation system ABB module HIEE450964R0001 SA9923A-E
Excitation system ABB module HIEE450880R1 LT8979A-V
Excitation system ABB module HIEE450848R1
Excitation system ABB module HIEE450824R1
Excitation system ABB module HIEE440503P201 HUCD420038R1 XTB750B01
Excitation system ABB module HIEE440207P2 HIEE320639R1 N7-10408-1/13
Excitation system ABB module HIEE410726P104 UNS0863 HIEE305082R0001
Excitation system ABB module HIEE410385P201 HIEE300550R1
Excitation system ABB module HIEE410379P201 HIEE401337R1
Excitation system ABB module HIEE410372P201 HIEE300590R1 HI107355-310/20
Excitation system ABB module HIEE410310P201 HIEE400923R1
Excitation system ABB module HIEE410226P2 HIEE200072R2 N7-10059-1/9
Excitation system ABB module HIEE410110P2
Excitation system ABB module HIEE410109P2 HIEE400320R1 HI901727-931/20
Excitation system ABB module HIEE410103P1
Excitation system ABB module HIEE410090P2 HIEE300115R1 HI201355-860-002
Excitation system ABB module HIEE410040P2
Excitation system ABB module HIEE410030P2 HIEE200008R2 HI903442-310/6
Excitation system ABB module HIEE410022P2 HIEE300025R2 HU202651-860-002
Excitation system ABB module HIEE410016P1 HIEE300024R4 N710315-8/15
Excitation system ABB module HIEE405246R0002 UNS0867A-PV2
Excitation system ABB module HIEE405246R0002 UNS0867A-P,V2
Excitation system ABB module HIEE405246R0002 UNS0867A-P,V2
Excitation system ABB module HIEE405227R0001
Excitation system ABB module HIEE405205R3 UNS0980C-PV3
Excitation system ABB module HIEE405179R0001 UNS0862A-PV1
Excitation system ABB module HIEE405179R0001 UNS0862A-P,V1
Excitation system ABB module HIEE405179R0001
Excitation system ABB module HIEE405087R1 UNS0982B-PV1
Excitation system ABB module HIEE405053R1 UN0803B-PV1
Excitation system ABB module HIEE401836R0001
Excitation system ABB module HIEE401782R0001 LTC391AE01
Excitation system ABB module HIEE401481R1 UAC326AE
Excitation system ABB module HIEE401481R0001 UAC326AW.V.1
Excitation system ABB module HIEE401481R0001 UAC326AE01
Excitation system ABB module HIEE40121P201 HIEE400403R2 HIEE300308R1
Reviews