Description
hardware flow control. It is an ideal choice in the field of industrial automation.
In the formula, a is the design acceleration/deceleration value: s is the current actual position value of the
elevator: V2 is the maximum speed of the elevator at this position.
Considering that the lifting system needs to enter the parking track at a low crawling speed when entering the
end of the stroke to avoid equipment damage caused by large mechanical impact, therefore, when there are still
1~5m away from the parking position, the lifting speed is limited to 0.5m/ below s.
Since the instantaneous speed before parking is very low, the position accuracy of the system”s parking can
be relatively improved, which is particularly important when the auxiliary shaft is lifted.
2.2 Design and implementation of security protection functions
Mines have particularly strict requirements on safety and reliability of hoist control systems [5]. While ensuring high
reliability of electrical control equipment, the control system also sets up multiple protections in key links where failures
may occur, and detects the actions and feedback signals of these protection devices in real time.
First of all, monitoring the operating status of the elevator is the top priority in the safety protection
function of the elevator control system. In the control system, the operating speed and position of the
motor are monitored at all times, and the current position and speed values are compared with the system”s
designed speed and position curve. Once it is found that the
actual operating speed of the hoist exceeds the designed speed value, immediately Issue an emergency
stop command and strictly ensure that the lifting speed is within the safe monitoring range during the entire
lifting process. At the same time, position detection switches are
arranged at several locations in the wellbore, and these position detection switches correspond to specific
position values and corresponding speed values. When the elevator passes these switches, if it is found through
encoder detection that the actual speed value and position deviate from the values corresponding to the position
detection switch, the control system will also judge that it is in a fault state
and immediately implement an emergency stop.
In order to determine whether the encoder connected to the main shaft of the elevator drum is normal,
two other encoders are installed on the elevator. In this way, the position and speed detection values
of the three encoders are always compared. Once it is found that the deviation between the detection
value of one encoder and the detection value of the other two encoders exceeds the allowable range,
the control system will immediately consider it to have entered a fault state and implement an emergency stop. Protective action.
3 Conclusion
The efficient and safe operation of main well equipment is an important guarantee for its function.
In the application of mine hoist, the 800xA system designed speed curve, self-correction, various
self-diagnosis and protection functions according to the specific process characteristics of the main
shaft mine hoist, which has achieved good results in practical applications.
https://www.xmamazon.com
https://www.xmamazon.com
https://www.plcdcs.com/
www.module-plc.com/
https://www.ymgk.com
A413139 Network I/O processor
DSTA131 Drive data manager controlling drives
PXIE-5105 High-density PXI oscilloscope
D201471 Digital input/output module
A413188 Multiprocessor system
IC200ALG320 Analog output module
D201376 Analog input module analog signals
XVR19 6U-VME-SBC Single board computer
D201190 Flow control valve high performance
CTB810 HN800 Communication terminal board
FPN1903A Switching power supply
CRIO-9073 controller embedded system
D3000 Dual protection mechanism
SHC68-68-EPM With redundant power input
BMXDDI3202K Input module into digital
BMXCPS2010 isolated power module
BMXDDO6402K Discrete quantity output module
1794-IF4IXT Motor control equipment
150-C85NBD Soft starter redundant input
HPC800底座MB810 Data collection and alarm management
A413139 Computer controller
VMIVME 3215-000 cpu module
PC834-001-T laboratory instruments
D201471 Digital input and output module
F860-CA High quality terminal board
MDB-8E Micro electronic balance
AI02J High precision current transmitter
FCM2F2 P0914YZ Bus extender
CRIO-9073 embedded controller
ZMI-4104 displacement measurement electronic
S30361-NA DANAHER servo controller
PW702 Power module overvoltag
REF610C11HCNN01(含底座) contactor
MVME55006E-0161R High performance embedded computer
87199-01 digital signal processor
MTL4842 Surge Protective Device
85UVF1A-1QD Solid state flame detector
EMERSON A6370D Digital expansion module
IC200PBI001 GE Network Interface Unit
CRIO-9073 NI CompactRIO Controller
85UVF1A-1QD Integrated Flame Scanner with Internal Relay
S30361-NA DANAHER KOLLMORGEN Servo driver
ZMI-4104 Displacement measurement Interferometers
PW702 YOKOGAWA Dc power module
“ABB AI02J A current transmitter”
Foxboro RH926GQ Distributed I/O module
FOXBORO FCM2F2 P0914YZ Bus expander
A-B 1756-IF4FXOF2F Analog input channel
VE4006P2 Programmable controller
136703-01 Communication module
ABB DSQC652 Standard IO signal board
EMERSON IC200PBI001 Network interface unit
Reviews