Description
3BHE023784R2330 Использование параметров ABB
Швейцария, и входит в десятку крупнейших швейцарских транснациональных корпораций.3BHE023784R2330
химическая, нефтехимическая, фармацевтическая, целлюлозно – бумажная, нефтепереработка; Оборудование приборов: электронные приборы, телевизоры и оборудование для передачи данных,
генераторы, гидротехнические сооружения; Каналы связи: интегрированные системы, системы сбора и распространения;3BHE023784R2330Строительная промышленность: коммерческое и промышленное строительство.
3.3 Design of computer control software
This type of control software runs on the computer and is mainly used for remote operation. It has multiple functions such as parameter setting, control operation,
data collection and storage, status detection and alarm, etc. Its interface is shown in Figure 3.
The system shown in Figure 3 contains four independent control channels, and the software can manage and configure the test plan based on parameter information.
That is: for each test plan, you can configure different test plans and set different test parameters through the “Configuration” operation. You can also create new plans,
save and modify plans, open existing plans, and delete plans.
The software also sets up quick operations, which can quickly start and stop work according to the channel configuration, and can detect the working status of
each channel in real time.
3.4 Design of touch screen software
The touch screen software is mainly used for local control and runs in the touch screen controller. While the computer control software has similar functions,
it also has the setting function of local control priority or remote control priority. The default is remote control priority. The login interface and test operation interface
are shown in Figure 4 and Figure 5 respectively.
3.5 Design of PLC software
As the core of this control system, PLC is mainly responsible for the following aspects:
Responsible for sending corresponding control parameters and instructions to the frequency converter, and at the same time obtaining the status
of the transmission system through the ProfibusDP bus protocol.
Communicates with the touch screen through serial communication, responds to local control instructions, and feeds back system status to the touch screen as a slave
computer for local control. Programming between the touch screen and PLC is performed by directly accessing the PLC variable address.
It communicates with the remote control computer through the OPC[5] communication method based on the external network, responds to the remote control instructions
, and feeds back the system status to the remote control computer as the remote control slave. Programming between the remote control program and the PLC is
performed by accessing the PLC variable name.
Process the emergency signal and control the inverter to slow down and unload according to the default parameters.
Figure 4 Login interface
Figure 5 Test interface
3.6 Frequency converter settings
In general, the inverter will be equipped with an optional operation panel. Before using the local or remote control program to operate the inverter,
you must first perform the basic settings of the inverter, as follows:
Switch the control mode to local control and set the inverter address according to the inverter user manual.
Set the inverter for remote control and select the communication mode.
Set the frequency converter to use an encoder, and connect the motor for self-test matching operation.
Set the speed control mode of the inverter, such as speed control or torque control.
After completing the basic parameter settings, switch to the remote control state and wait for remote control.
4 Conclusion
This system implements a universal belt-turning mechanism that utilizes frequency conversion control technology. You can use the local touch screen to
control the inverter to control the motor
rotation and obtain corresponding feedback, or you can use remote control to control the inverter to achieve the same control effect as the local touch screen,
even in view of the computer function The richness allows you to obtain more system information and set more control states. In addition to local touch screen
control and remote control, the overall structure of this system can also be split into the most basic transmission structure to complete the control, that is,
the motor is controlled directly through the
control panel of the frequency converter to achieve the most basic and direct control. Therefore, this system can be used as a basic framework structure to
meet all similar control requirements, and obtain different levels of usage requirements through different levels of hardware configuration, which has universal reference significance.
DS200DMCBG1AKG GE
DS200DPCBG1AAA GE
DS200DSPCH1ADA GE
DS200FGPAG1AFC GE
DS200FGPAG1A DS200FGPAG1AFC
DS200FGPAG1A GE
DS200FGPAG1AHD GE
DS2020FECNRX025A GE
DS200FSAAG2ABA GE
DS200IIBDG1A GE
DS200IQXSG1AAA GE
DS215KLDBG1AZZ03A GE
DS200KLDBG1ABC DS215KLDBG1AZZ03A
DS200KLDBG1ABC GE
DS200LDCCH1AGA GE
DS200LDCCH1ANA GE
DS200LPPAG1AAA GE
DS200PCCAG1ABB GE
DS200RTBAG2AFB GE
DS215SDCCG1AZZ01A GE
DS200SDCCG1AEC GE
DS200SDCCG1AFD GE
DS200SDCCG1AGD GE
DS200SDCCG5AHD GE
DS200SDCIG1ABA GE
DS200SDCIG2AEB GE
DS200SDCIG2AHB GE
DS200SIOBH1AAA GE
DS200SIOBH1ABA GE
DS200SIOBH1ACA GE
DS215SLCCG1AZZ01A DS200SLCCG1ACC
DS215SLCCG1AZZ01A GE
DS200SLCCG1ACC GE
DS215SLCCG1AZZ01B GE
DS215SLCCG1AZZ01A GE
DS200SLCCG1AEE DS215SLCCG1AZZ01A DS215SLCCG1AZZ01B
DS215SLCCG1AZZ01A DS200SLCCG1AEE
DS215SLCCG1AZZ01A DS215SLCCG1AZZ01B
DS200SLCCG1AEE GE
DS200SLCCG1AFG GE
DS200TBQCG1AAA GE
DS200TBQDG1AFF GE
Reviews