3BHE019719R0101 GVC736BE101 Использование параметров ABB
Швейцария, и входит в десятку крупнейших швейцарских транснациональных корпораций.3BHE019719R0101 GVC736BE101
химическая, нефтехимическая, фармацевтическая, целлюлозно – бумажная, нефтепереработка; Оборудование приборов: электронные приборы, телевизоры и оборудование для передачи данных,
генераторы, гидротехнические сооружения; Каналы связи: интегрированные системы, системы сбора и распространения;3BHE019719R0101 GVC736BE101Строительная промышленность: коммерческое и промышленное строительство.
3.2 Upgrading of regulators and control systems
For the upgrade of the regulator, the original excitation control system cabinet structure is retained, and the entire system is upgraded by upgrading the board card.
Among them, the CoB main board, MUB measurement board, F10 input and output board, and LCP local control panel were replaced with the PEC800 controller,
CCM measurement control interface board, CIo comprehensive input and output board, and ECT excitation system control terminal in the Unitrol6800 system respectively.
For the upgrade of the power cabinet, since the power of the excitation system will not change during the transformation, the N-1 redundant configuration of the five
UNL3300 rectifier bridges in the original system has not been changed, but the control and measurement parts of the rectifier
bridge have been upgraded. And the fan circuit and power control part of the rectifier bridge have been upgraded. Among them, the signal interface board (PsI) was
changed to the rectifier bridge signal interface board (CsI), the circuit breaker of the rectifier bridge panel was changed from CDP to CCP, and the rectifier bridge control
interface board (CIN) was changed to the rectifier bridge control board (CCI).
For the upgrade of the demagnetization cabinet, the switch control part was mainly upgraded. By adding a CIo board to the switch cabinet and installing a special
power distributor and relay to control the demagnetization switch, the original PsI board was removed. Secondly, in the transformation of the current detection part,
the Hall element in the Unitrol5000 system was replaced by the current relay of the Unitrol6800 system.
For the upgrade of the excitation current measurement part, the rectifier side Hall element of the rectifier bridge was replaced with an AC side CT. Relying on the linearity of the
CT, the current sharing coefficient of the excitation system was increased to 0.98, so that the role of the rectifier bridge can be fully exerted in the system. .
For the upgrade of the fan power supply circuit of the rectifier cabinet, each power cabinet can independently control the power supply of the fans in the
cabinet to avoid the problem that if the power circuit relay fails in the original system, all the fans will not work.
3.3Unitrol6800 functional logic configuration points
The Unitrol6800 system adds PT slow-blow judgment logic, and defines the actions of PT slow-blow as alarm and channel switching. The system PT
slow-blow logic pressure difference is 2% to ensure sufficient sensitivity. Since some external reasons will cause the sequential increase or decrease of magnetic
commands, a special increase or decrease magnetic contact adhesion judgment logic has been added to effectively lock out external causes. At the same
time, it can
avoid the jitter of the relay on the increase or decrease magnetic circuit and ensure the stability of the circuit. The excitation temperature detection is used to
alarm in the system, but it cannot control the system tripping. The tripping intermediate relays K291 and K292 use high-power (≥5w) relays to avoid
the problem of tripping of the excitation system
due to signal interference.
4 Problems discovered during the transformation and their solutions
After upgrading the excitation system from Unitrol5000 to Unitrol6800, since the partition between the regulator cabinets of the original excitation switch
cabinet was removed and the mounting backplate of the regulator was moved forward, the hot air from the excitation switch cabinet will enter the excitation regulator
cabinet, causing the cabinet to be damaged. The internal temperature rises, and sometimes the temperature can even reach 45°C. In order to avoid problems caused
by high temperatures, partitions were added to reduce the temperature inside the switch cabinet and control the
temperature to 30°C.
During the maintenance process, if the grounding carbon brush of the generator is removed, it is easy to cause the rotor grounding relay isoLR275 to
malfunction. Therefore, during maintenance, the power supply of the grounding relay will be disconnected and the large shaft in the magnetic cabinet will be short-circuited.
5 Conclusion
Through the transformation of the excitation system, our company not only meets the needs of increasing the generator capacity, but also
eliminates the safety hazards of ARCnet failure or flat cable damage in the excitation system of the unit. It can find the fault point during maintenance
and prevent the unit from non-stop. event. The new board used in the new excitation system has modular characteristics, which can make online maintenance more
convenient, and because the boards use trigger pulse generation communication and optical fiber redundant communication, the stability of
information transmission is ensured. Avoid communication failures and damage to pulse lines.
FI810F ABB AC800F fieldbus module
PM802F 3BDH000002R1 ABB Base Unit Field Controller
CI860K01 3BSE032444R1 ABB FF HSE Interface
PM862K02 3BSE081636R1 ABB Redundant Processor Unit
PM665 3BDS005799R1 ABB Processor Module
PM891K01 3BSE053241R1 ABB Redundant Processor Unit
PM867K01 3BSE076355R1 ABB Redundant Processor Unit
PM866AK02 3BSE081637R1 ABB Redundant Processor Unit
PM866AK01 3BSE076939R1 ABB Redundant Processor Unit
PM866K02 3BSE050199R1 ABB Redundant Processor Unit
PM865K02 ABB Redundant Processor Unit HI
PM866K01 3BSE050198R1 ABB Processor Unit
PM865K01 ABB Processor Unit Kit
PM595-4ETH-F ABB AC500CPU
PM864AK01 ABB Processor Unit Kit, ABB AC 800M
PM862K01 ABB Processor Unit Kit
PM861AK02 ABB Processor Unit Kit, ABB AC 800M
PM861AK01 ABB Processor Unit Kit
PM860K01 ABB Processor Unit Kit, ABB AC 800M
PM856K01 ABB Unit Kit
PM851K01 ABB Processor Unit Kit, ABB AC 800M
FEN-31 ABB HTL Encoder Interface
DSDX452L 5716075-U ABB Remote In / Out Basic Unit
DSDX451 5716075-K ABB Basic Unit – Digital Input/Output
DO880 3BSE028602R1 ABB Digital Output
DO802 3BSE022364R1 ABB Digital Output
CI853K01 ABB Communication Interface
AO810-3BSE008522R1 ABB Analog Output Module
AO801 ABB Analog Output Module
1756-OF4 Allen-Bradley ControlLogix Four (4) channel analog output module
1756-OB32 Allen-Bradley ControlLogix Discrete output module
1756-IB32 Allen-Bradley input module
1756-DNB Allen-Bradley ControlLogix Scanner Module
X20PS9400 B&R supply module
VE4003S2B1 EMERSON Standard I/O Termination Block
SST-PFB-CLX SST Remote Rack Configuration
S20360-SRS KOLLMORGEN Servo driven drive
REX521GHHGSH05G ABB PROTECTION UNIT
REF541KB115AAAA ABB FEEDER TERMINAL
PHARPS320000000 ABB Power supply module
MTL831C MTL Instruments Analog Transmitter
MC-4/11/10/400 ELAU SERVO DRIVE
CPCI-5565PIORC-210000 GE PXI Reflective Memory Module
CPCI-5565PIORC-110000 GE PXI Reflective Memory Module
PMC-5565PIORC-210000 GE Reflective Memory PMC Node Card
PMC-5565PIORC-110000 GE Reflective Memory PMC Node Card
PCIE-5565PIORC-200A00 GE Reflective Memory PCI Express Node Card
81001-355-71-R Allen-Bradley Silicon controlled inverter module