Description
hardware flow control. It is an ideal choice in the field of industrial automation.
Practical application of ABB industrial information control system 800xA in main shaft hoist control
introduction
The mine hoist is an important transportation equipment for mining enterprises. Its main function is to transport the ore,
personnel or equipment that need to be transported to the destination by the lifting container. Therefore, it plays a very
important role in the mining production process. Usually the mine hoist control system consists of a driving part and a
control part. The working mechanism
of the driving part is: the motor unit drives the mechanical hoisting device, and the frequency converter or other types
of hoisting control systems drive the motor unit: the working mechanism of the control part is: Each component of the
hoist is coordinated and controlled by the
Distributed Control System (DCS). In addition to completing basic process control, it can also integrate intelligent instruments,
intelligent transmission and motor control, and even production management and safety systems into one operation and engineering environment
middle. Therefore, the mine hoist requires a control system with high performance, high reliability, and high integration.
1ABB800xA system and AC800M controller introduction
1.1ABB800xA system introduction
The 800xA system is an industrial information control system launched by ABB. The core of its architecture is
object-oriented (ObjectOriented) technology. Due to the adoption of ABB”s unique Aspect0object concept,
enterprise-level information access, object navigation and access can become standardized and simple.
In order to provide a unified information platform for enterprise managers and technical personnel, the 800xA system
provides a base platform (BasePlatform), which relatively separates the process control part and production control
management and organically combines them together. As shown in Figure 1, the middle part is the basic platform, the upper part is the production control
management part, and the lower part is the process control part. The basic platform provides standard interfaces for
these two parts for data exchange.
1.2 Introduction to ABBAC800M controller and its programming configuration tools
AC800M controller is ABB”s latest controller series, which includes a series of processors from PM851 to PM865.
The AC800M controller itself has a pair of redundant TCP/IP interfaces. It can use the MMs protocol to communicate
with other control devices and 800xA operator stations through Ethernet. It can also use the Modbus protocol and
Point-Point protocol through 2 serial ports. communication. The programming and configuration tool of AC800M is
ControlBuilderM,
referred to as CBM. It supports standard ladder diagram, function block language, text description
language and assembly language to write control logic.
2. Improve the design and implementation of control system functions
2.1 Implementation of elevator operating speed curve
One of the main tasks of the lifting control system is to control the lifting motor to operate according to the speed-position
curve given by the design, so that the lifting container passes through the acceleration section, the uniform speed
section and the deceleration section successively, and stops accurately after completing the specified lifting distance
. somewhere in the wellbore. In order to realize the function of precise position calculation, the designed
elevator control system must be able to perform high-precision position calculation based on the photoelectric encoder
connected to the main shaft of the elevator drum. The
calculation formula is as follows:
In the formula, s is the actual position value of the elevator: sp is the distance corresponding to two consecutive encoder
pulses: AN is the difference between the encoder count value at the reference position and the current position (signed variable):
s0 is the reference position value.
The encoder counts are distributed according to the circumference of the drum. After the number of pulses Np generated
by the encoder rotation is known, the diameter of the circumference of the centerline of the wire rope wrapped around the
drum must be accurately known, so that it can be calculated according to formula (2) The distance sp corresponding to the two encoder pulses:
In the formula, D is the circumferential diameter of the centerline of the wire rope: Np is the number of pulses for one revolution of the known encoder.
But in formula (2), there is a value D that keeps getting smaller as the system runs. This is because the wire rope
used in the elevator is wrapped around the drum, and there is a lining between the wire rope and the drum that increases
friction. This liner will become thinner and thinner as the system continues to wear and tear, causing the diameter of the
circle formed by the center line of
the steel wire rope to gradually become smaller. When the pad wears to a certain extent, it will cause a large position
calculation error. In order to solve the above problems, the two parking position switches in the shaft are used to correct the drum diameter, because the
distance between the two parking positions can be obtained through actual measurement with high accuracy. During the
actual operation, record the encoder count values at the two parking positions respectively. According to formula (3),
the actual correction value of sp can be calculated:
In the formula, sd is the distance between two parking positions: Abs is the absolute value operation: N is the
encoder count value when there are two parking positions.
In this way, the initial sp value is first set according to the given design parameter value, and then the value is
corrected according to the actual operating conditions, which can effectively ensure the accuracy of position
calculation. At the same time, sp” can also be substituted into formula (2), and the D value can be obtained in turn,
which can be used as a basis for judging whether the liner is seriously worn.
After obtaining the elevator position value, the speed control curve can be calculated according to formula (4):
https://www.xmamazon.com
https://www.xmamazon.com
https://www.plcdcs.com/
www.module-plc.com/
https://www.ymgk.com
2213-75TSLKTB JDSU 75mW Argon Laser (with rings)
1420-V2P-ENT Allen-Bradley monitoring system module
5X00121G01 Westinghouse Switch quantity output module
6ES7716-2CB10-0EC4 Siemens SIMATIC FIELD PG M4 PREMIUM PLUS
5X00119G01 Westinghouse Controller Module
2N3A3110-C TOSHIBA Assembly Controller Board
1TGE120021R0010 ABB Communication Gateway
2094-BM01-S Allen-Bradley Kinetix 6000 Drive component
FC-SDO-0824 Honeywell Safety Manager System Module
FC-SAI-1620M Honeywell Safety Manager System Module
FCS01.1E-W0011-A-04-NNBV Rexroth FC Frequency Converters
EX404MCRD5 TOSHIBA PROGRAMMABLE CONTROLLER
EVR116 PFEIFFER Gas mass flowmeter intake control valve
EPC1200T-N270-2GB-40SS-XP Nematron Screen
ECU01.5 EMG display
EASYGEN 3200 Woodward Series Genset Engine Controller
EL3068 BECKHOFF analog input terminal processes signals
EGCP-3 8406-113 Woodward Load Sharing EGCP-3 Model
E82ZAFP LENZE COMMUNICATION MODULE
E84AHWMC1534V-V003 LENZE
E33NCHA-LNN-NS-00 Pacific Scientific Hybrid Step Motor
DXA-205 EMERSON Positioning Servo Drive
E111A12X3N ETON CONTACTOR
DLD13004R PARKER Digital servoamplifier
DVC2000 Fisher Digital Valve Controller
DKCXX.3-100-7 Rexroth DKC Drive Controllers
DDLS200/200.1-60 LENZE optical data transceiver
DB-5 Schneider PacDrive Distribution Box
HD22010-3 EMERSON Rectifier Module
AE6000-4 DITTEL Grinding process monitoring module
HP 5517B Agilent Laser interferometer
CP451-10 Yokogawa Processor Module
XVME-653 Xycom VMEbus Pentium Processor Module
ACC-24E2A 4-AXIS Delta Tau Analog Interface Module
702060/188-888-000-23 Jumo Compact Microprocessor Controller
A860-2109-T302 FANUC ALPHA-i 10,000 RPM SPINDLE CODER
805405-1R RELIANCE single-phase field power module
8222215.14.17 SEW CONTROL BOARD
XVM-403-TBNS-0000 EMERSON Servo Motor
XV-430-12TSB-1-10 ETON Touch Panel
3500/61 Bently Nevada Temperature Monitors
VE4001S2T2B1 EMERSON Discrete Input Card
330101-00-08-20-12-05 Bently Nevada 3300 XL 8mm Proximity Transducer Probe
146031-01 Bently Nevada Transient Data Interface I/O Module
8440-1706/A Woodward synchronizer modules
6186M-17PT Allen-Bradley display monitor
1756-PH75 Allen-Bradley 125 Volts DC Input Voltage
1381-648241-12 Tokyo Electron PCB
1747-SDN Allen-Bradley SLC 500 DeviceNet Scanner Module
1747-L532 Allen-Bradley SLC 5/03 controller module
839-13521-1 MKS HPS Isolation Gate Valve
440R-W23222 Allen-Bradley Safety Relay
620-0073C HONEYWELL ETHERNET LOOP PROCESSOR MODULE
90-20-0-003 CONTROL CHIEF (2400) COMMUNICATION MODULE
85UVF1-1CEX Fireye Integrated Flame Scanner with Internal Flame Relay
TDM1.3-050-300-W1-000 Rexroth TDM Drive Modules
07KT98 ABB Basic Module Ethernet AC31
31C015-503-4-00 SEW Movitrac Eurodrive AC Inverter Unit
Reviews
There are no reviews yet.