hardware flow control. It is an ideal choice in the field of industrial automation.
3.3 Design of computer control software
This type of control software runs on the computer and is mainly used for remote operation. It has multiple functions such as parameter setting, control operation,
data collection and storage, status detection and alarm, etc. Its interface is shown in Figure 3.
The system shown in Figure 3 contains four independent control channels, and the software can manage and configure the test plan based on parameter information.
That is: for each test plan, you can configure different test plans and set different test parameters through the “Configuration” operation. You can also create new plans,
save and modify plans, open existing plans, and delete plans.
The software also sets up quick operations, which can quickly start and stop work according to the channel configuration, and can detect the working status of
each channel in real time.
3.4 Design of touch screen software
The touch screen software is mainly used for local control and runs in the touch screen controller. While the computer control software has similar functions,
it also has the setting function of local control priority or remote control priority. The default is remote control priority. The login interface and test operation interface
are shown in Figure 4 and Figure 5 respectively.
3.5 Design of PLC software
As the core of this control system, PLC is mainly responsible for the following aspects:
Responsible for sending corresponding control parameters and instructions to the frequency converter, and at the same time obtaining the status
of the transmission system through the ProfibusDP bus protocol.
Communicates with the touch screen through serial communication, responds to local control instructions, and feeds back system status to the touch screen as a slave
computer for local control. Programming between the touch screen and PLC is performed by directly accessing the PLC variable address.
It communicates with the remote control computer through the OPC[5] communication method based on the external network, responds to the remote control instructions
, and feeds back the system status to the remote control computer as the remote control slave. Programming between the remote control program and the PLC is
performed by accessing the PLC variable name.
Process the emergency signal and control the inverter to slow down and unload according to the default parameters.
Figure 4 Login interface
Figure 5 Test interface
3.6 Frequency converter settings
In general, the inverter will be equipped with an optional operation panel. Before using the local or remote control program to operate the inverter,
you must first perform the basic settings of the inverter, as follows:
Switch the control mode to local control and set the inverter address according to the inverter user manual.
Set the inverter for remote control and select the communication mode.
Set the frequency converter to use an encoder, and connect the motor for self-test matching operation.
Set the speed control mode of the inverter, such as speed control or torque control.
After completing the basic parameter settings, switch to the remote control state and wait for remote control.
4 Conclusion
This system implements a universal belt-turning mechanism that utilizes frequency conversion control technology. You can use the local touch screen to
control the inverter to control the motor
rotation and obtain corresponding feedback, or you can use remote control to control the inverter to achieve the same control effect as the local touch screen,
even in view of the computer function The richness allows you to obtain more system information and set more control states. In addition to local touch screen
control and remote control, the overall structure of this system can also be split into the most basic transmission structure to complete the control, that is,
the motor is controlled directly through the
control panel of the frequency converter to achieve the most basic and direct control. Therefore, this system can be used as a basic framework structure to
meet all similar control requirements, and obtain different levels of usage requirements through different levels of hardware configuration, which has universal reference significance.
Display operation panel TPU3-EX 3HNA010905-001
Display operation panel TPSTU02
Display operation panel TPS02
Display operation panel TPPB-02 3HNA02320000101
Display operation panel TPPB-02 3HNA023200-001/01
Display operation panel TPM810
Display operation panel TPM01
Display operation panel TP910F
Display operation panel TP867 3BSE043664R1
Display operation panel TP867
Display operation panel TP867
Display operation panel TP858 3BSE018138R1
Display operation panel TP858
Display operation panel TP857 3BSE030192R1
Display operation panel TP857
Display operation panel TP854 3BSE025349R1
Display operation panel TP854 3BSE025349R1
Display operation panel TP854
Display operation panel TP854
Display operation panel TP854
Display operation panel TP853
Display operation panel TP853
Display operation panel TP852 3BSC950263R1
Display operation panel TP851
Display operation panel TP830
Display operation panel TP830
Display operation panel TMM-700
Display operation panel TK891F
Display operation panel TK891F
Display operation panel TK890F
Display operation panel TK890F
Display operation panel TK854V030
Display operation panel TK853V020
Display operation panel TK851V010/3BSC950262R1
Display operation panel TK850V007
Display operation panel TK831F
Display operation panel TK831F
Display operation panel TK821F
Display operation panel TK821F
Display operation panel TK817F
Display operation panel TK817F
Display operation panel TK812V150
Display operation panel TK812V050
Display operation panel TK812V050
Display operation panel TK812V015
Display operation panel TK812V015
Display operation panel TK811V150
Display operation panel TK811V150
Display operation panel TK811V050
Display operation panel TK811V050
Display operation panel TK811V015
Display operation panel TK811V015
Display operation panel TK811F
Display operation panel TK811F
Display operation panel TK809F
Display operation panel TK809F
Display operation panel TK808F
Display operation panel TK807F
Display operation panel TK807F
Display operation panel TK803V018 3BSC950130R1
Display operation panel TK802F
Display operation panel TK802F
Display operation panel TK801V012
Display operation panel TK801V012
Display operation panel TK801V006
Display operation panel TK801V006
Display operation panel TK801V003/3BSC950089R1
Display operation panel TK801V003
Display operation panel TK801V003
Display operation panel TK701F
Display operation panel TK527V030
Display operation panel TK516 3BSE000388R1
Display operation panel TK516
Display operation panel TK212A
Display operation panel TK212A
Display operation panel TK212
Display operation panel TK212
Display operation panel TD951F
Display operation panel TC630
Display operation panel TC625
Display operation panel TC562
Display operation panel TC560V2 3BSE022178R1
Display operation panel TC520 3BSE001449R1
Display operation panel TC514
Display operation panel TC512V1 3BSE018059R1
Display operation panel TC512V1
Display operation panel TC512
Display operation panel TC405K03
Display operation panel TBU810
Display operation panel TB870F
Display operation panel TB870F
Display operation panel TB852
Display operation panel TB852
Display operation panel TB850 3BSC950193R1
Display operation panel TB850
Display operation panel TB850
Display operation panel TB845
Display operation panel TB842
Display operation panel TB840A 3BSE037760R1
Reviews
There are no reviews yet.