Description
hardware flow control. It is an ideal choice in the field of industrial automation.3.3 Design of computer control software
This type of control software runs on the computer and is mainly used for remote operation. It has multiple functions such as parameter setting, control operation,
data collection and storage, status detection and alarm, etc. Its interface is shown in Figure 3.
The system shown in Figure 3 contains four independent control channels, and the software can manage and configure the test plan based on parameter information.
That is: for each test plan, you can configure different test plans and set different test parameters through the “Configuration” operation. You can also create new plans,
save and modify plans, open existing plans, and delete plans.
The software also sets up quick operations, which can quickly start and stop work according to the channel configuration, and can detect the working status of
each channel in real time.
3.4 Design of touch screen software
The touch screen software is mainly used for local control and runs in the touch screen controller. While the computer control software has similar functions,
it also has the setting function of local control priority or remote control priority. The default is remote control priority. The login interface and test operation interface
are shown in Figure 4 and Figure 5 respectively.
3.5 Design of PLC software
As the core of this control system, PLC is mainly responsible for the following aspects:
Responsible for sending corresponding control parameters and instructions to the frequency converter, and at the same time obtaining the status
of the transmission system through the ProfibusDP bus protocol.
Communicates with the touch screen through serial communication, responds to local control instructions, and feeds back system status to the touch screen as a slave
computer for local control. Programming between the touch screen and PLC is performed by directly accessing the PLC variable address.
It communicates with the remote control computer through the OPC[5] communication method based on the external network, responds to the remote control instructions
, and feeds back the system status to the remote control computer as the remote control slave. Programming between the remote control program and the PLC is
performed by accessing the PLC variable name.
Process the emergency signal and control the inverter to slow down and unload according to the default parameters.
Figure 4 Login interface
Figure 5 Test interface
3.6 Frequency converter settings
In general, the inverter will be equipped with an optional operation panel. Before using the local or remote control program to operate the inverter,
you must first perform the basic settings of the inverter, as follows:
Switch the control mode to local control and set the inverter address according to the inverter user manual.
Set the inverter for remote control and select the communication mode.
Set the frequency converter to use an encoder, and connect the motor for self-test matching operation.
Set the speed control mode of the inverter, such as speed control or torque control.
After completing the basic parameter settings, switch to the remote control state and wait for remote control.
4 Conclusion
This system implements a universal belt-turning mechanism that utilizes frequency conversion control technology. You can use the local touch screen to
control the inverter to control the motor
rotation and obtain corresponding feedback, or you can use remote control to control the inverter to achieve the same control effect as the local touch screen,
even in view of the computer function The richness allows you to obtain more system information and set more control states. In addition to local touch screen
control and remote control, the overall structure of this system can also be split into the most basic transmission structure to complete the control, that is,
the motor is controlled directly through the
control panel of the frequency converter to achieve the most basic and direct control. Therefore, this system can be used as a basic framework structure to
meet all similar control requirements, and obtain different levels of usage requirements through different levels of hardware configuration, which has universal reference significance.
Email: 3221366881@qq.com
https://www.xmamazon.com
https://www.xmamazon.com
https://www.plcdcs.com/
www.module-plc.com/
https://www.ymgk.com
FSCA-01 RS-485 Adapter module
701PGNKF Intelligent power module
1606-XLB240E Power module
IC693BEM330 FIP remote I/O scanner
F3YD64-1P YOKOGAWA Transistor output module
F3YD32-1P YOKOGAWA Transistor output module
F3YP12-0V YOKOGAWA Transistor output module
1734-CTM Input/output common terminal module
20P41AD330RA0NNN Three-phase AC driver
1769-SDN DeviceNet Communication module
2080-LC50-24AWB Programmable Logic controller
2080-LC50-24QBB Compact controller
20F1ANC205JN0NNNNN Adjustable frequency AC driver
25A-D043N114 PowerFlex 523 Series compact low voltage driver
22C-D038A103 AC Powerflex 400 drive
BCU-12 Control unit BCU12
FEN-31 68978955 HTL encoder interface
1769-OF4 Analog output module
MPS022 13100-203 Power module
1784-PKTX/A Network interface card
1FK2104-5AF11-1MA0 servo motor
3G3MX2-A4040-ZV1 multifunctional mini frequency converter
2711-K6C5 PanelView Standard Operator Terminal
1769-IF16C Compact I/O mode
Drive ACS880-01-109A-3 ABB
5069-L320ERS2 compact GuardLogix controller
1783-US16T Ethernet unmanaged switch
1783-BMS10CGL Managed Ethernet switch
2198-D020-ERS3 Kinetix 5700 two-axis servo drive
5069-OBV8S Security output module
AL81G ACQUISITIONLOGIC single-channel Analog input board
05701-A-0281 Single channel control card 05701-A-0281
CG6565/64-2L/8TE NMS Media processing board
D0C-16C SAMSUNG Digital Output and counting board
05701-B-0376 HONEYWELL control card module
05701-A-0303 HONEYWELL control card module
1756-OW16I ControlLogix discrete output module
1756-IRT8I ControlLogix Analog input module
1756-EN2TP Allen-Bradley Communication module
1756-OF8H Allen-Bradley analog output module
1756-IF16H Allen-Bradley analog input module
REF615 HBFDACADABC1BNN21G feeder protection and measurement and control device
Pxi-2510 NI PXI signals are inserted into the switch module
AKM34H-ANC2R-00 KOLLMORGEN brushless servo motor
AKM230-ANCNR-00 KOLLMORGEN servo motor
AKM32H-ANC2R-00 KOLLMORGEN servo motor
MPL-B680H-MJ74AA low inertia servo motor
3500/15-02-02-00 Power module
1794-IB32 Flex I/O DC input module
CX5130-0125 Embedded computer processor
MHD115C-035-PG0-AA MHD synchronous motor
PCIe-6734 NI Multifunctional I/ O device
140ERT85410 Multifunctional input module
SPM-D2-101010B/YB 8440-2167 Synchronizer
Reviews
There are no reviews yet.