Description
hardware flow control. It is an ideal choice in the field of industrial automation.
Distinguished according to whether there is a position sensor, first of all, it is divided into sensing
and non-sensing. That is, whether Hall or other similar position sensors are used to sense the
position angle of the stator and rotor. In air pump applications, many use non-inductive control.
The excellent algorithm of through-hole is that after the motor is running, it detects the changes in
phase current to switch the phase current. In some heavy-duty or precise control applications,
sensory methods are used.
According to the three-phase power supply of the inverter, it can be divided into square wave control
and sine wave control. The square wave control strategy is simple, and the control process is direct
and effective. It adopts a six-step commutation strategy. The CPU modulates the PWM to drive the
power switch tube to generate a three-phase power supply that can run the motor. The control strategy
of sine wave is relatively complex, but the control effect is much better.
In sine wave control, there are two main control strategies.
One is direct torque control DTC Baidu Encyclopedia. The method is to calculate the estimated values
of motor flux and torque based on the measured motor voltage and current. After controlling the torque,
the motor speed can also be controlled. Direct torque control is a patent of the European ABB company. .
The second is, space vector control FOC Baidu Encyclopedia. Its essence is to equate an AC motor to a DC
motor, and independently control the speed and magnetic field components. By controlling the rotor flux linkage,
and then decomposing the stator current, the two components of torque and magnetic field are obtained. After
coordinate transformation, the normal motor is realized. handover or decoupling control.
During sine wave control, there are many derived more sophisticated control strategies, such as feedforward
control, maximum torque control, field weakening control, etc.
In the process of controlling the motor, there are multiple feedback control loops. When controlling the output
of the motor, there is a current loop; on this basis, there is a control loop that controls the speed; when a servo
motor is used, there is a position loop control.
DR1B-02AC AC servo driver
DR1-08ACY25 AC servo driver
810-046015-010 LAM Interface board module
F8627X/F8628X HIMA New communication module
F8621A 984862160 Processor module HIMA
135137-01 Location I/O module with internal terminal
1C31169G02 Link Controller
133396-01 Overspeed detection I/O module
F6217 984621702 8-channel analog input module
F3330 984333002 Channel 8 output module
F3237 984323702 Channel 16 input module
F7553 984755302 Coupling module HIMA
MHD041A-144-NG0-UN MHD series synchronous motor
XO08R2 1SBP260109R1001 Relay output expansion module
woodward EGCP-3 8406-113 Engine generator control package
CP451-50 YOKOGAWA processor module
TRICONEX TRICON 4352B Communication module
810-801237-021 LAM uses the pulse output of PLC
GRBTU-01 3BSE013175R1 ABB Module base unit
CI854K01 3BSE025961R1 Profibus-DP/V1 port Kit 800xA controller
CC-IP0101 51410056-175 Profibus Dp gateway
140CPU67160 With multi-mode Ethernet
TRICON 3511 pulse input module
TRICON 3700/3700A Analog Input Modules
80165-178-52C ALLEN BRADLEY PC BOARD
TRICON 3701 TMR Analog Input Module
TOSHIBA 2J3K2313-C Controller Board
TOSHIBA 2N3A3120-D PC BOARD ASSEMBLY
TOSHIBA 2N3A8130-A Frequency converter module
TOSHIBA 2N3A3620-B Controller Board
SEW 31C005-503-4-00 AC DRIVE
SEW 31C015-503-4-00 Ac drive
SEW 31C055-503-4-00 MOVITRAC
SEW 31C075-503-4-00 Frequency converter