Description
hardware flow control. It is an ideal choice in the field of industrial automation.
In the formula, a is the design acceleration/deceleration value: s is the current actual position value of the
elevator: V2 is the maximum speed of the elevator at this position.
Considering that the lifting system needs to enter the parking track at a low crawling speed when entering the
end of the stroke to avoid equipment damage caused by large mechanical impact, therefore, when there are still
1~5m away from the parking position, the lifting speed is limited to 0.5m/ below s.
Since the instantaneous speed before parking is very low, the position accuracy of the system”s parking can
be relatively improved, which is particularly important when the auxiliary shaft is lifted.
2.2 Design and implementation of security protection functions
Mines have particularly strict requirements on safety and reliability of hoist control systems [5]. While ensuring high
reliability of electrical control equipment, the control system also sets up multiple protections in key links where failures
may occur, and detects the actions and feedback signals of these protection devices in real time.
First of all, monitoring the operating status of the elevator is the top priority in the safety protection
function of the elevator control system. In the control system, the operating speed and position of the
motor are monitored at all times, and the current position and speed values are compared with the system”s
designed speed and position curve. Once it is found that the
actual operating speed of the hoist exceeds the designed speed value, immediately Issue an emergency
stop command and strictly ensure that the lifting speed is within the safe monitoring range during the entire
lifting process. At the same time, position detection switches are
arranged at several locations in the wellbore, and these position detection switches correspond to specific
position values and corresponding speed values. When the elevator passes these switches, if it is found through
encoder detection that the actual speed value and position deviate from the values corresponding to the position
detection switch, the control system will also judge that it is in a fault state
and immediately implement an emergency stop.
In order to determine whether the encoder connected to the main shaft of the elevator drum is normal,
two other encoders are installed on the elevator. In this way, the position and speed detection values
of the three encoders are always compared. Once it is found that the deviation between the detection
value of one encoder and the detection value of the other two encoders exceeds the allowable range,
the control system will immediately consider it to have entered a fault state and implement an emergency stop. Protective action.
3 Conclusion
The efficient and safe operation of main well equipment is an important guarantee for its function.
In the application of mine hoist, the 800xA system designed speed curve, self-correction, various
self-diagnosis and protection functions according to the specific process characteristics of the main
shaft mine hoist, which has achieved good results in practical applications.
https://www.xmamazon.com
https://www.xmamazon.com
https://www.plcdcs.com/
www.module-plc.com/
https://www.ymgk.com
3500/15 127610-01 BENTLY overspeed protection module
3500/20 125768-01 BENTLY overspeed protection module
3500/92-02-01-00 Transient Data Interface BENTLY
3500/92-04-01-00 BENTLY vibration monitoring system
3500/42 125672-02 BENTLY4 Channel Relay Module
3500/54-03-00 Transient Data Interface BENTLY
1900/65A-00-01-01-00-00 BENTLY overspeed protection module
3500/42M 176449-02 BENTLY overspeed protection module
3500/25 149369-01 Transient Data Interface BENTLY
135473-01 Transient Data Interface BENTLY
3500/42 176449-02 Transient Data Interface BENTLY
3500/22M BENTLY overspeed protection module
128276-01 Transient Data Interface BENTLY
3500/22M 288055-01 BENTLY overspeed protection module
3500/15-02-02-00 Temperature monitor BENTLY
146031-01 BENTLY4 Channel Relay Module
35000/22M (138607-01) Temperature monitor BENTLY
3500/33-01-00 BENTLY4 Channel Relay Module
3500/15-02-02-00 BENTLY vibration monitoring system
3500/15-02-02-01 BENTLY overspeed protection module
3500/22M 288055-01 BENTLY4 Channel Relay Module
3500/05-01-02-00-00-00 BENTLY vibration monitoring system
1900/65A-00-02-02-00-01 Transient Data Interface BENTLY
3500/54-03-00 BENTLY vibration monitoring system
3500/15 114M5330-01 BENTLY overspeed protection module
128275-01 BENTLY4 Channel Relay Module
3500/33-01-CN Transient Data Interface BENTLY
3500/15-02-02-00 BENTLY4 Channel Relay Module
3500/05-01-02-00-00-00 BENTLY4 Channel Relay Module
3500/15-02-02-00 BENTLY overspeed protection module
1900/65A-00-02-02-00-01 BENTLY4 Channel Relay Module
3500/05-01-01-00-00-01 BENTLY vibration monitoring system
3500/92-03-01 BENTLY overspeed protection module
3500/40M 176449-01 BENTLY4 Channel Relay Module
3500/15 106M1081-01 Transient Data Interface BENTLY
3500/72-01-00 BENTLY overspeed protection module
3500/42-04-00 Temperature monitor BENTLY
125840-02 Temperature monitor BENTLY
3500/42M 176449-02 BENTLY overspeed protection module
106M1079-01 BENTLY overspeed protection module
3500/25-01-02-01 BENTLY vibration monitoring system
3500/05-01-02-00-00-01 Temperature monitor BENTLY
3500/22M 288055-01 Transient Data Interface BENTLY
3500/32 125720-01 Transient Data Interface BENTLY
3500/93-01-00-00 Transient Data Interface BENTLY
3500/15 125840-01 BENTLY4 Channel Relay Module
3500/22-01-01 BENTLY4 Channel Relay Module
3500/22M 288055-01 BENTLY4 Channel Relay Module
3500/54-03-00 Temperature monitor BENTLY
3500/15 114M5335-01 Temperature monitor BENTLY
125680-01 Temperature monitor BENTLY