Description
hardware flow control. It is an ideal choice in the field of industrial automation.
In the formula, a is the design acceleration/deceleration value: s is the current actual position value of the
elevator: V2 is the maximum speed of the elevator at this position.
Considering that the lifting system needs to enter the parking track at a low crawling speed when entering the
end of the stroke to avoid equipment damage caused by large mechanical impact, therefore, when there are still
1~5m away from the parking position, the lifting speed is limited to 0.5m/ below s.
Since the instantaneous speed before parking is very low, the position accuracy of the system”s parking can
be relatively improved, which is particularly important when the auxiliary shaft is lifted.
2.2 Design and implementation of security protection functions
Mines have particularly strict requirements on safety and reliability of hoist control systems [5]. While ensuring high
reliability of electrical control equipment, the control system also sets up multiple protections in key links where failures
may occur, and detects the actions and feedback signals of these protection devices in real time.
First of all, monitoring the operating status of the elevator is the top priority in the safety protection
function of the elevator control system. In the control system, the operating speed and position of the
motor are monitored at all times, and the current position and speed values are compared with the system”s
designed speed and position curve. Once it is found that the
actual operating speed of the hoist exceeds the designed speed value, immediately Issue an emergency
stop command and strictly ensure that the lifting speed is within the safe monitoring range during the entire
lifting process. At the same time, position detection switches are
arranged at several locations in the wellbore, and these position detection switches correspond to specific
position values and corresponding speed values. When the elevator passes these switches, if it is found through
encoder detection that the actual speed value and position deviate from the values corresponding to the position
detection switch, the control system will also judge that it is in a fault state
and immediately implement an emergency stop.
In order to determine whether the encoder connected to the main shaft of the elevator drum is normal,
two other encoders are installed on the elevator. In this way, the position and speed detection values
of the three encoders are always compared. Once it is found that the deviation between the detection
value of one encoder and the detection value of the other two encoders exceeds the allowable range,
the control system will immediately consider it to have entered a fault state and implement an emergency stop. Protective action.
3 Conclusion
The efficient and safe operation of main well equipment is an important guarantee for its function.
In the application of mine hoist, the 800xA system designed speed curve, self-correction, various
self-diagnosis and protection functions according to the specific process characteristics of the main
shaft mine hoist, which has achieved good results in practical applications.
https://www.xmamazon.com
https://www.xmamazon.com
https://www.plcdcs.com/
www.module-plc.com/
https://www.ymgk.com
PMA323BE HIEE300308R1 ABB board
DSPC174 3BSE005461R1 ABB Analog input module
DSSB140 48980001-P ABB power module
PFSK160A 3BSE009514R1 ABB processor board
PFSK162 3BSE015088R1 ABB module
PFSK164 3BSE021180R1 ABB Analog I/O Modules
PFSK130 3BSE002616R1 ABB module
IC693MDL644 GE Series 90-30 DC Voltage Input Module
IC693MDL645CA GE Programmable Logic Controllers
IC693MDL645 GE Series 90-30 module
IC693MDL645LT GE Programmable Logic Controllers
IC693MDL646 GE Series 90-30 Discrete Input module
IC693MDL646LT GE 40 Volts DC rated PLC
IC693MDL646CA GE Series 90-30, 24 VDC Positive / Negative Logic discrete input module
IC693MDL648 GE 40 Volts DC rated PLC
IC693MDL654CA GE 5/12 volt DC (TTL) Positive/Negative Logic Input module
IC693MDL653 GE Series 90-30, 24 VDC Positive / Negative Logic discrete input module
IC693MDL654 GE 5/12 volt DC (TTL) Positive/Negative Logic Input module
IC693MDL654LT GE Series 90-30 Discrete Input module
IC693MDL655CA GE Series 90-30 Discrete Input module
IC693MDL655 GE Series 90-30 Discrete Input module
IC693MDL655LT GE Series 90-30 Discrete Input module
IC693MDL660 GE Series 90-30, 24 VDC Positive / Negative Logic discrete input module
IC693MDL740 GE Series 90-30 module
IC693MDL734LT GE 12/24 positive logic DC output module
IC693MDL740CA GE OUTPUT MODULE
IC693MDL741 GE 12/24 positive logic DC output module
IC693MDL740LT GE digital I/O module
IC693MDL741CA GE 12/24 positive logic DC output module
IC693MDL741LT GE digital I/O module
IC693MDL742 GE Protection (ESCP) Output module
IC693MDL748 GE digital I/O module
IC693MDL742LT GE Series 90-30, 12/24 VDC Positive logic output module
IC693CPU351 GE Series 90-30 component
IC693MDL750 GE digital I/O module
IC693MDL751 GE 32-point output module
IC693MDL752CA GE Output module
IC693MDL752 GE output module
IC693MDL752LT GE Output module
IC693MDL753CA GE positive logic output module
IC693MDL753LT GE 12/24 volt DC, 0.5A Positive Logic Output module
IC693MDL754 GE positive logic output module
IC693MDL760 GE digital output module
IC693MDL916 GE Series 90-30, relay output module
IC693MDL730 GE Series 90-30 12/24 VDC Positive logic output module
VME162PA-344SE-2G MOTOROLA Embedded Controller
URSHA GE Redesigned Power Supply Module
SR489-P5-LO-A20-E GE 489 Series Motor Management Relay
SR750-P1-G1-S1-HI-A20-R-E GE Multilin SR750 Relay
MC-4/11/22/400 ELAU Servo drive driver
PCH1026 GE Acceleration acceleration sensor
SR469-P5-LO-A20-E GE Multilin SR469 Relay
IS220PPROH1A GE Mark VI component
IS200TSVOH2B GE TERMINATION BD., SERVO
IC754VSI06STD-LH GE Operator Interface Products line
IC697PWR711K GE Power Supply Module
Reviews
There are no reviews yet.