Nine Questions and Answers on Common Faults in ABB Industrial Robot Applications
Question 1: Under what circumstances do I need to back up my robot?
Answer: 1. After the new machine is powered on for the first time.
2. Before making any modifications.
3. After completing the modification.
4. If the robot is important, conduct it regularly once a week.
5. It is best to make a backup on a USB flash drive.
6. Delete old backups regularly to free up hard drive space.
Second question: What does the alarm message 10106 maintenance time reminder mean when the robot appears?
Answer: This is the intelligent periodic maintenance reminder of ABB robots.
Question 3: What should I do if the robot enters a system failure state when it is powered on?
Answer: 1. Restart the robot.
2. If it doesn”t work, check whether there is a more detailed alarm prompt on the teaching pendant and handle it.
3. Restart.
4. If it still cannot be lifted, try B startup.
5. If it still doesn’t work, try P startup.
6. If it still doesn’t work, try I startup (this will return the robot to factory settings, be careful).
Question 4: Can robot backup be shared by multiple robots?
Answer: No, for example, the backup of robot A can only be used for robot A, not robots B or C, because this will cause system failure.
Five questions: What files can be shared in the robot backup?
Answer: If the two robots are of the same model and configuration. You can share RAPID programs and EIO files, but they must be verified before they can be used normally.
Question 6: What is the mechanical origin of the robot? Where is the mechanical origin?
Answer: The six servo motors of the robot have a unique fixed mechanical origin. Incorrectly setting the mechanical origin of the robot will cause problems such
as limited movement or malfunction of the robot, the inability to walk in a straight line, etc., and serious damage to the robot.
Question 7: How to cancel the robot 50204 motion monitoring alarm?
Answer: 1. Modify the robot action monitoring parameters (control panel – action monitoring menu) to match the actual situation.
2. Use the AccSet command to reduce the robot”s acceleration.
3. Reduce the v_rot option in the speed data.
Eight questions: What should I do if the robot alarms “50296, SMB memory data difference” when it is powered on for the first time?
Answer: 1. Select calibration in the ABB main menu.
2. Click ROB_1 to enter the calibration screen and select SMB memory.
3. Select “Advanced” and click “Clear Control Cabinet Memory” after entering.
4. Click “Close” when finished, then click “Update”.
5. Select “The control cabinet or robot has been exchanged, and the control cabinet is updated using SMB memory data.”
Question 9: How to customize the speed of robot trajectory in the RAPID program?
Answer: 1. Select program data in the main menu of the teaching pendant.
2. After finding the data type Speeddata, click New.
3. Click on the initial value. The meanings of the four variables of Speeddata are: v_tcp represents the linear operating speed of the robot, v_rot
represents the rotational operating speed of the robot, v_leax represents the linear operating speed of the additional axis, v_reax represents the rotational
operating speed of the additional axis, if there is no additional axis, then No need to modify the two.
4. The customized data can be called in the RAPID program.
https://www.xmamazon.com
https://www.xmamazon.com
https://www.plcdcs.com/
www.module-plc.com/
https://www.ymgk.com
WOODWARD 8440-1301
WOODWARD 8440-2088
WOODWARD 8440-1936
WOODWARD 8440-2150
WOODWARD 8440-1947
WOODWARD 8440-1809
WOODWARD 8440-2152
WOODWARD 8440-1936
WOODWARD 8440-1884
WOODWARD 8440-1868
WOODWARD 8440-1952
WOODWARD 8440-1878
8440-2222 – Woodward’s easYgen
WOODWARD 8200-203- ProTech 203 overspeed protection
WOODWARD 8200-508
WOODWARD 8200-314 – Digital Driver Board
Woodward Rotary actuators | VBR Turbine Partners 8200-188
WOODWARD 8200-1204 – LINKnet HT AIO
WOODWARD 8200-224 – Servo Position Controller
WOODWARD Governor 8200-150
WOODWARD 8200-226
Woodward 9907-205 MSLC/DSLC Hand Held Programmer
WOODWARD 8200-507 Steam Turbine Digital Governor
WOODWARD 8200-1300
WOODWARD 8200-1302 – 505D Digital Governor Turbine Control
Woodward 505D Digital Speed Governing Turbine Controller 8200-1502
WOODWARD 8200-1508
WOODWARD 8200-1350 Flex500- Turbines
WOODWARD 8200-1301-505D Digital Governor Turbine Control
WOODWARD 8200-1310 Turbine Digital Control
WOODWARD 5464-050 Digital Microprocessor Controller
5466-258 | 5466-258 Woodward | Simplex Discrete I/O Module
WOODWARD 5464-674 Digital Microprocessor Controller
WOODWARD 5464-738
WOODWARD microgrid digital control 5464-552
WOODWARD 5464-843
WOODWARD 5464-331 Digital Microprocessor Controller
WOODWARD 5464-333- Thermocouple input module available in stock
WOODWARD 5464-011
WOODWARD 5464-365A
WOODWARD 5464-365 Module digital speed sensor
WOODWARD 5464-330
WOODWARD 5464-218
Best WOODWARD 5464-643 discrete input (48 channels)
WOODWARD 5464-654
WOODWARD 5464-850
WOODWARD 5464-545
WOODWARD 5464-414
“WOODWARD 9905-003”
“WOODWARD EASYGEN-1000”
“WOODWARD EASYGEN-320”
“WOODWARD ESAYGEN-1000”
“WOODWARD 9907-018”
“WOODWARD 9907-163”
woodward 9907-163
Reviews
There are no reviews yet.