Model: 05704-A-0121
Brand: Honeywell
Size: 10cm x 10cm x 30cm
Weight: 1.2KG
Color: White Black
Working voltage: 5V
Working temperature: -10 ℃ to 50 ℃
Communication interface: RS232, RS485, CAN
Product specifications
Support for MODBUS protocol
Support hardware flow control
Using high-speed CMOS devices
Support for data caching
application area
05704-A-0121 is mainly used in the field of industrial automation, such as DCS PLCs, industrial controllers, robots, etc.
05704-A-0121 is mainly used in steel manufacturing, thermal power generation, hydroelectric power generation, glass manufacturing, paper mills, cement factories, petrochemicals
Chemical fiber, pharmaceutical manufacturing, rubber, plastics, ferrous metal food, machine tools, specialized equipment, transportation vehicles, mechanical equipment
Electronic communication equipment, instruments and beverages, tobacco processing, clothing, textiles, leather, wood processing, furniture, printing, etc
Model: 05704-A-0121 Brand: ABB Archive Function: Communication Function Product Certification: Qualified
Working voltage: 24V Internal variable: No pattern Type: Vector diagram Applicable range: Industrial type
Number of screens: 4 Imported or not: Yes Customized for processing: No
Alarm function: Product name: Module Input voltage: 24V Rated current: 5A
Special service: including postage. Remarks: one-year warranty. Operation method: remote control
Applicable motor: servo motor system memory: 8MB Display color: 99.9 color gamut
Power voltage: 220V Input method: Current Input Material code: 65218
Communication interface: HDMI interface Working temperature: 60 Material number 26854 Other functions Analog communication
Output frequency: 50HZ Rated voltage: 24V Alarm type: Light alarm
Disconnect capacity: 0.01 Vector graph support: Minimum number of packages supported: 1
Display type: IPS USB interface quantity: 2 interfaces Memory card slot: 2
Panel protection level: 3 Memory expansion capacity: 128MB User script support: supported
Speed response frequency: 1MS Working environment temperature: -40 to 100 Insulation withstand voltage test: Passed
Third party communication products: ABB controllers available for sale in: nationwide
Product Instructions
Please install 05704-A-0121 correctly on the device and connect the communication interface cable properly.
Please refer to the user manual for operating 05704-A-0121 to ensure proper use.
Product Introduction
05704-A-0121 is a high-performance industrial automation communication module that uses high-speed CMOS devices, supports MODBUS protocol, and supports
hardware flow control. It is an ideal choice in the field of industrial automation.

Implementation of communication between ABC industrial robot and PLC based on DeviceNet fieldbus technology
introduction

In modern production systems, industrial robots and PLCs need to communicate and collaborate to complete production tasks. That is, the
industrial robots output signals to the PLC, allowing the PLC to control related equipment to drive the robot”s front-end tools. This article
mainly analyzes the communication problems between ABB industrial robots and PLC based on DeviceNet fieldbus technology.
DeviceNet is a common network communication method in the field of automation. ABB industrial robots establish a network to communicate with
Siemens PLC based on the DeviceNet network.

1Configure DSQC652

There are mainly 5 types of standard I/0 boards commonly used in ABB industrial robots [2]. Except for the different addresses assigned to
them during setup, their configuration methods are basically the same. This article mainly analyzes the ABB standard I/0 board DS0C652, which
mainly builds communication modules based on the DeviceNet network. The DS0C652 board has a distributed I/O module with 16 digital input and 16
digital output interfaces. The board is installed in the ABB industrial robot control cabinet. First, define the specific operation steps of the DS0C652 board,
enter the teach pendant control panel, then enter the configuration menu (Figure 1), select the DeviceNetDevice menu, and add a template to enter Figure 2.
ABB standard I/0 board is hung on the DeviceNet
network, so the address of the module in the network must be set. The jumpers 6 to 12 of terminal x5 are used to determine the address of the module.
The available address range is 10 to 63. Modify the parameters in the template parameters to complete the DS0C652 board settings. Click the drop-down
menu to select the “Use value from template” row, select
“DS0C65224VDCI/0Device”, and then the parameters that need to be set include the address of the I/0 board in the bus.
Figure 1 Configuring DSQC652

2Configure signals and parameters

After completing the DS0C652 board setting, the I/0 signal setting will be performed. Setting the I/0 signal is the basis for establishing communication with
the PLC. The PLC communicates and transmits data with the ABB industrial robot through the I/0 signal and the DS0C652 board. As shown in Figure 3, in the
signal configuration interface, there are many default I/0 points after the system is established. Modification is not allowed. Click “Add” to add signals. When setting
input and output signals, their address range is 0~15. First, enter the signal menu in the configuration options to set the input and output types, and modify the corresponding parameters.
After completing the settings, the computer prompts that you need to restart the settings. If there are multiple signals that need to be defined and the waiting time
is long after restarting multiple times, you can click “Cancel” and wait for all signals to be defined before clicking the “Yes” button to restart. After the signal settings are
completed, click to select “Input and Output” in the ABB menu to check whether all signals have been set.
Figure 2 Configure DSQC652 parameters
Figure 3 Signal parameter settings

During the signal establishment process, attention should be paid to the DSoC652 port and PLC port addresses used, and the corresponding address table should be
established, as shown in Table 1. The robot interacts with the PLC through I/O signals. During the setting process, there must be no errors in the port and address number
of the PLC connected to the DSoC652. If the address is set incorrectly, the communication between the robot and the PLC will not work properly.

The entire robot teaching pendant setting process is shown in Figure 4.

Contact person: Mr. Lai
Mobil:17750010683
WeChat:17750010683
WhatsApp:+86 17750010683
Email: 3221366881@qq.com

https://www.xmamazon.com

https://www.xmamazon.com

Home

Home

https://www.plcdcs.com/

www.module-plc.com/

https://www.ymgk.com

MKD090B-058-GP0-KN
MKD090B-058-GG1-KN
MKD090B-058-GG0-KN
MKD090B-047-KP1-KS
MKD090B-047-KP1-KN
MKD090B-047-KP0-KN/SA001
GE  IS220YDIAS1A-Mark VI IS200
BENTLY  3500/42M
BENTLY  3500/65
IS200SSCAH2AGD GE
IS220PTURH1A GE
IS220PTCCH1A  GE
IS200JPDHG1AAA GE
GE Mark VI IS200SRLYH2A – In Stock Now – Ready to Ship
IS420UCSBH1A GE Mark VIe UCSB Controller
MKD090B-047-KP0-KN   REXROTH
MKD090B-047-KG2-KN   REXROTH
MKD090B-047-KG1-KN   REXROTH
MKD090B-047-KG0-KN   REXROTH
MKD090B-047-GP2-KN   REXROTH
MKD090B-047-GP1-KN/SA001   REXROTH
MKD090B-047-GP1-KN   REXROTH
MKD090B-047-GP0-KN/SA001   REXROTH
MKD090B-047-GP0-KN   REXROTH
MKD090B-047-GG1-KN   REXROTH
REXROTH   MKD090B-047-GG0-KN
MKD090B-046-KG0-KN   REXROTH
MKD090B-035-KP2-KN   REXROTH
MKD090B-035-KP1-KN   REXROTH
MKD090B-035-KP0-KN   REXROTH
MKD090B-035-KG2-KN   REXROTH
REXROTH   MKD090B-035-KG1-KN
MKD090B-035-KG0-KN   REXROTH
MKD090B-035-GP1-KN   REXROTH
MKD090B-035-GP0-KN/SA001   REXROTH
MKD090B-035-GP0-KN   REXROTH
MKD090B-035-GG2-KN   REXROTH
MKD090B-035-GG1-KN   REXROTH
MKD090B-035-GG0-KN   REXROTH
MKD071B-097-KP0-BN    REXROTH
REXROTH      MKD071B-097-KG1-BN
MKD071B-097-KG1-AN     REXROTH
MKD071B-097-GP1-BN  REXROTH
MKD071B-097-GP0-BN  REXROTH
MKD071B-061-KP3-KN  REXROTH
MKD071B-061-KP1-KN/SA001  REXROTH
MKD071B-061-KP0-KS  REXROTH
MKD071B-061-KP0-KN/SA001   REXROTH
MKD071B-061-KP0-KN REXROTH
MKD071B-061-KG3-KN  REXROTH

Reviews

There are no reviews yet.

Be the first to review “05704-A-0121 Output module Honeywell”

Your email address will not be published. Required fields are marked *