Description
hardware flow control. It is an ideal choice in the field of industrial automation.
3.2 Upgrading of regulators and control systems
For the upgrade of the regulator, the original excitation control system cabinet structure is retained, and the entire system is upgraded by upgrading the board card.
Among them, the CoB main board, MUB measurement board, F10 input and output board, and LCP local control panel were replaced with the PEC800 controller,
CCM measurement control interface board, CIo comprehensive input and output board, and ECT excitation system control terminal in the Unitrol6800 system respectively.
For the upgrade of the power cabinet, since the power of the excitation system will not change during the transformation, the N-1 redundant configuration of the five
UNL3300 rectifier bridges in the original system has not been changed, but the control and measurement parts of the rectifier
bridge have been upgraded. And the fan circuit and power control part of the rectifier bridge have been upgraded. Among them, the signal interface board (PsI) was
changed to the rectifier bridge signal interface board (CsI), the circuit breaker of the rectifier bridge panel was changed from CDP to CCP, and the rectifier bridge control
interface board (CIN) was changed to the rectifier bridge control board (CCI).
For the upgrade of the demagnetization cabinet, the switch control part was mainly upgraded. By adding a CIo board to the switch cabinet and installing a special
power distributor and relay to control the demagnetization switch, the original PsI board was removed. Secondly, in the transformation of the current detection part,
the Hall element in the Unitrol5000 system was replaced by the current relay of the Unitrol6800 system.
For the upgrade of the excitation current measurement part, the rectifier side Hall element of the rectifier bridge was replaced with an AC side CT. Relying on the linearity of the
CT, the current sharing coefficient of the excitation system was increased to 0.98, so that the role of the rectifier bridge can be fully exerted in the system. .
For the upgrade of the fan power supply circuit of the rectifier cabinet, each power cabinet can independently control the power supply of the fans in the
cabinet to avoid the problem that if the power circuit relay fails in the original system, all the fans will not work.
3.3Unitrol6800 functional logic configuration points
The Unitrol6800 system adds PT slow-blow judgment logic, and defines the actions of PT slow-blow as alarm and channel switching. The system PT
slow-blow logic pressure difference is 2% to ensure sufficient sensitivity. Since some external reasons will cause the sequential increase or decrease of magnetic
commands, a special increase or decrease magnetic contact adhesion judgment logic has been added to effectively lock out external causes. At the same
time, it can
avoid the jitter of the relay on the increase or decrease magnetic circuit and ensure the stability of the circuit. The excitation temperature detection is used to
alarm in the system, but it cannot control the system tripping. The tripping intermediate relays K291 and K292 use high-power (≥5w) relays to avoid
the problem of tripping of the excitation system
due to signal interference.
4 Problems discovered during the transformation and their solutions
After upgrading the excitation system from Unitrol5000 to Unitrol6800, since the partition between the regulator cabinets of the original excitation switch
cabinet was removed and the mounting backplate of the regulator was moved forward, the hot air from the excitation switch cabinet will enter the excitation regulator
cabinet, causing the cabinet to be damaged. The internal temperature rises, and sometimes the temperature can even reach 45°C. In order to avoid problems caused
by high temperatures, partitions were added to reduce the temperature inside the switch cabinet and control the
temperature to 30°C.
During the maintenance process, if the grounding carbon brush of the generator is removed, it is easy to cause the rotor grounding relay isoLR275 to
malfunction. Therefore, during maintenance, the power supply of the grounding relay will be disconnected and the large shaft in the magnetic cabinet will be short-circuited.
5 Conclusion
Through the transformation of the excitation system, our company not only meets the needs of increasing the generator capacity, but also
eliminates the safety hazards of ARCnet failure or flat cable damage in the excitation system of the unit. It can find the fault point during maintenance
and prevent the unit from non-stop. event. The new board used in the new excitation system has modular characteristics, which can make online maintenance more
convenient, and because the boards use trigger pulse generation communication and optical fiber redundant communication, the stability of
information transmission is ensured. Avoid communication failures and damage to pulse lines.
https://www.xmamazon.com
https://www.xmamazon.com
https://www.plcdcs.com/
www.module-plc.com/
https://www.ymgk.com
Usb-5133 8-bit USB oscilloscope device
PCI-6040 Multi-function I/O device
PCI-5105 oscilloscope/digitizer
PCI-8511 Single or dual-port low-speed/fault-tolerant CAN interface device
PCI-8513 Fieldbus CAN device
PCI-8512 high-speed/FD CAN interface device
PCI-6221 16-bit multi-function I/O device
PCI-6071 Multi-function I/O device
PCI-7813 Digital reconfigurable input/output device
PCI-7811 Multi-function I/O device
PCI-5640 intermediate frequency transceiver device
PCI-6036E Multi-function DAQ device
PCI-6035 Multifunctional DAQ device
PCI-8516 PCI Bus interface board
TP857 3BSE030192R1 substrate unit
XVS-440-10MPI-1-1AD EATON Operator interface panel
ZYGO 7714 8070-0279-01 Interferometer
4351B TRICONEX Communication Modules
RELIANCE Y-3023-2-H00AA Brushless servo motor
3BHE005555R0101 LDSYN-101 Printed tape circuit board
IS215ACLEH1B GE EX2100 Excitation Controller
GE 04220FL11232A RXI CONTROLLER Dominate industry
FCP270 P0917YZ Field Control Processor 270
FC-TSHART-1620M UNIVERSAL SAFETY INTERFACE
Cutler-Hammer C825KN10 3 Pole Contactor
3500/22M Transient data interface
XVC768115 3BHB7211R115 Printed circuit board
“ABB UNITROL 1005-0011 ECO 3BHE043576R0011 Indirect Excitation Systems”
ABB SYNCHROTACT 5 3BHB006713R0217 microprocessor Supplied by XIONGBA
ABB SAM3.0 counter Supplied by XIONGBA
REF620E_F NBFNAANNNCC1BNN1X Feeder protection and control relay
PCD235B1101 3BHE032025R1101 Supplied by XIONGBA
3500/92 Communication Gateway xiongba Automation
3500/62 6 channel monitor Supplied by XIONGBA
3500/61 Thermocouple temperature input xiongba Automation
3500/60 temperature detector Supplied by XIONGBA
3500/53 Electronic Overspeed Detection System xiongba Automation
3500/42M Proximitor Seismic Monitor Supplied by XIONGBA
3500/33 16 channel relay module XIONGBA supply
3500/32 4 Channel Relay Module Supplied by XIONGBA
3500/25 Enhanced Keyphasor Module XIONGBA Industries
3500/15 Power module of half height Supplied by XIONGBA
350005-01-01-00-00-01 System Rack XIONGBA spare parts
330730-080-00-00 3300 XL 11 mm Extension Cable Supplied by XIONGBA
136180-01 COMMUNICATION GATEAWAY MODULE XIONGBA spare parts
125840-01 Ac power input module Supplied by XIONGBA
125800-01 KEYPHASOR I/O MODULE
8440-2165 SPM-D2-11 The synchronizer of a microprocessor
106M1081-01 Universal AC Power Input Module
DSTS106 3BSE007287R1 Trigger pulse Generator cassette backup regulator
DI650 3BHT300025R1 Digital input 32 channels
DSTS105 3BSE007286R1 is used to simulate a backup regulator
3500/92-02-01-00 Communication gateway
TC515V2 3BSE013284R1 AF100 Twisted pair repeater
DSAI155A 3BSE014162R1 thermocouple module
TC512V1 3BSE018059R1 RS485 Twisted pair modem
DSAO130A 3BSE018294R1 Analog output board 16 channels
DSTA155P 3BSE018323R1 Connect unit 14 thermocouple
DSTA002B 3BSE018317R1 Analog input board connection unit
DSTA135 3BSE018315R1 input board
DSTD190V1 3BSE018314R1 Connects to unit 32 Ch