Description
hardware flow control. It is an ideal choice in the field of industrial automation.
We can perform simulation algorithms on Matlab.
3. The role of frequency converter
1. Frequency conversion energy saving
The energy saving of frequency converters is mainly reflected in the application of fans and water pumps. In order to ensure the reliability of production, various
production machines have a certain margin when they are designed to be equipped with power drives. When the motor cannot operate at full load, in addition to
meeting the power drive requirements, the excess torque increases the consumption of active power, resulting in a waste of electrical energy. The traditional speed
adjustment method for fans, pumps and other equipment is to adjust the air supply volume and water supply volume by adjusting the opening of the baffles and valves
at the inlet or outlet. The input power is large, and a large amount of energy is consumed in the interception process of the baffles and valves. middle. When using variable
frequency speed regulation, if the flow requirement is reduced, the requirement can be met by reducing the speed of the pump or fan.
The purpose of using a frequency converter for a motor is to regulate speed and reduce starting current. In order to produce variable voltage and frequency, the device first converts
the alternating current from the power supply into direct current (DC), a process called rectification. The scientific term for a device that converts direct current (DC) into alternating
current (AC) is “inverter”. Generally, an inverter converts DC power into an inverter power supply with a certain fixed frequency and voltage. The inverter with adjustable frequency and
adjustable voltage is called a frequency converter. The waveform output by the frequency converter is a simulated sine wave, which is mainly used for speed regulation of three-phase
asynchronous motors, also called a variable frequency speed regulator. For variable frequency inverters that are mainly used in instrumentation and testing equipment and
have higher waveform requirements, the waveforms need to be sorted and can output standard sine waves, which are called variable frequency power supplies. Generally, the price
of variable frequency power supply is 15-20 times that of the inverter. Since the main device in the inverter equipment that produces changing voltage or frequency is called “inverter”,
the product itself is named “inverter”, that is: inverter.
Frequency conversion does not save power everywhere, and there are many occasions where using frequency conversion does not necessarily save power. As an electronic circuit,
the frequency converter itself also consumes power (about 3-5% of the rated power). A 1.5-horsepower air conditioner consumes 20-30W of electricity, which is equivalent to a
continuous light. It is a fact that the inverter runs at power frequency and has a power-saving function. But his prerequisite is:
https://www.xmamazon.com
https://www.xmamazon.com
https://www.plcdcs.com/
www.module-plc.com/
https://www.ymgk.com
1B30035H01 Westinghouse I/O PROCESS CONTROL BASE
1785-BCM Allen-Bradley Backup Communications Module
1771-W Allen-Bradley Field connection arm
R-S108V01-16-24VDC-C10-1 PHOENIX Communication system
AD916CC FOXBORO Programmable logic controller
AD908MF FOXBORO Programmable logic controller
1756-TBNH Allen-Bradley removable terminal block or RTB module
1769-L32CA Allen-Bradley Processor Module
PHARPS32200000 F8-G2B9B3B6 ABB Power Supply
GFD233A 3BHE022294R0101 ABB Competitive Pricing
VMIPCI-5565-110000 VMIC Reflective Memory Interface
PFEA111-20 3BSE028140R0020 ABB Tension Electronics
FBMSSW FOXBORO INVENSYS I/O 32 Channels Module
SDCS-CON-4 3ADT313900R1501 ABB COAT-ROHS CONTROL BOARD
MOX12-P3509 ABSOPULSE POWER SUPPLY
IS200ISBBG2AAB GE Rack type power board
FBM216 P0917TN FOXBORO HART Communication Redundant Input Interface Module
FSE-L003 SCHENCK Front bus controller
301140 pliz safety relays
CPU-30ZBE D143-502-A002 FRCE Communication Module
1746-N2 Allen-Bradley SLC 500 Slot Filler
RDC2 BERGHOF Controller Module
1746-A4 Allen-Bradley SLC 500 I/O Chassis with 4 Slots
30V4060 RELIANCE 3HP 460V AC Drive Version 6 Regulator
1C31116G04 Westinghouse controller
LC100SSP7 LEM 1382 Circuit Board
TU810V1 3BSE013230R1 ABB Compact Module Termination
PPC907BE 3BHE024855R0101 ABB Controller main board
UTLH21 TOSHIBA Controller Module
9907-149 Woodward ProTech 203 Electronic Overspeed Trip Device
HFAS11S TOSHIBA System module
5136-RE2-PCI RELIANCE ELECTRIC INTERFACE MODULE
1756-EN2T Allen-Bradley communication module
MVI69-MNET PROSOFT Modbus TCP/IP Communication Module for CompactLogix
1747-L541 Allen-Bradley SLC 5/04 processor
5X00119G01 19-01-21 Westinghouse Digital quantity input module
5X00121G01 19-01-21 Westinghouse Digital quantity input module
1C31124G01 19-01-21 Westinghouse Digital input module
5X00497G01 19-01-21 Westinghouse The base
1756-RM2 19-01-18 Allen-Bradley ControlLogix Redundancy Module
1746-OW16 19-01-18 Allen-Bradley discrete output module
1X00416H01 WH5-2FF 19-01-18 Westinghouse Process control power module
PSFLT-B2S0151 IDP10-AF1C01F Foxboro I/A Series Pressure Transmitters
MVI56-MCM Allen-Bradley Modbus Communication Module
1756-L73/B Allen-Bradley ControlLogix Controller
TC-PCIC02 HONEYWELL CONTROL INTERFACE MODULE
IK340 HEIDENHAIN Operation station
FBMSVH FOXBORO Ethernet communication module
DSQC658 3HAC025779-001 ABB DeviceNet M/S single
6DD1640-0AH0 Siemens TDC signal assembly