Description
hardware flow control. It is an ideal choice in the field of industrial automation.
3Configuring Siemens PLC
For PLC, Siemens S-1200PLC is used. Siemens PLC needs to be configured and programmed in Botu software.
After the program
is completed, the communication settings between the robot and PLC can be set. First, select the device and
network in the Porto software, then add a new device and select the controller model as Siemens 1212, as shown
in Figure 5. After adding the device, you need to set up
the PLC network. The computer and PLC must set corresponding IP addresses in the same network segment to
facilitate downloading and uploading PLC programs. After the settings are completed, click on the project tree
on the left to select the program block, and then enter
program writing. After the entire program is written, you can check whether the robot has received the signal from
the PLC through the input and output menu call in the ABB industrial robot teaching pendant, or you
can check online whether the PLC has received the signal from the
robot through the Botu software. When the line connection is good, the operator can set some signals to
complete the test work. If the test communication is normal, further PLC programming can be performed.
Figure 5 Botu software configures new equipment
4 Conclusion
This article explains in detail the communication setting process between ABB industrial robots and Siemens
PLC, making full use of the characteristics of industrial fieldbus technology. During the communication process
, signal settings are based on DeviceNet fieldbus technology. The actual operation verifies the content described
in this article. feasibility. In communication settings, special attention should be paid to the process of setting parameters such as address signals. Based on
DeviceNet fieldbus technology, communication between ABB industrial robots and PLCs can be completed more
quickly and conveniently.
In modern industry, the communication technology between industrial robots and PLC has improved the level
of production line automation and can better utilize the flexible and expandable characteristics of industrial robots.
Therefore, it is foreseeable that the application of communication technology in the production line will continue to
increase, thus exerting a great influence on industrial production. greater effect.
https://www.xmamazon.com
https://www.xmamazon.com
https://www.plcdcs.com/
www.module-plc.com/
https://www.ymgk.com
SPDSO15 Digital output module
SPDSO14 digital output module
SPDSM04 Pulse In Module
SPDSI22 Digital input module
SPDSI14 Digital input module
SPDSI13 Digital Slave Input Module
SPCIS22 Control I/O Module
SPASO11 AO Module 14 CH, Supports 4-20mA, 1-5V
SPASI23 AI Module
SPTKM01 SOE Time Keeper Master
SPSEM11 SOE Master Module
SPNPM22 Network Processor Module
SPNIS21 Network Interface Module
SPIPT800 PN800 Transfer Module
SPIIT13 Local Transfer Mod
SPIIT12 Remote Transfer Mod
SPIIL02-L Local interface suite
SPIET800 Ethernet CIU Transfer Module
SPICT13A S+ Infi-net to Computer Interface Module
SPICI800 Ethernet CIU Kit
SPCPM02 RS-232 Serial interface
SPBRC410 Modbus Indicates the controller of the TCP interface
SPBRC400 Controller with Expanded Memory
SPBRC300 Controller module
SPBLK01 Control System module
PBA800 Process Bus Adaptor HN800
INTKM01 time Keeper Master Module
INSEM11 Sequence of Events Master Module
INNPM22 Network Processor Module
INNIS21 Network Interface Slave module
INIET800 Communication Module
INICT13A HR series controller
IMBLK01 Blank Faceplate HR Series
KEBA FM 265/A Profibus Interface module of the slave station
FC-TSHART-1620M Analog input module
FC-TSAI-1620M Analog input module
F7553 Coupling Module HIMA
HIMA 8-Channel Output Module F3330
HIMA F3236 igital Input Module
Flowserve F5-MEC-420 Feedback unit valve positioner
Mark V DS200DCFBG1BLC Power Supply Board