Description
hardware flow control. It is an ideal choice in the field of industrial automation.
3.2 Upgrading of regulators and control systems
For the upgrade of the regulator, the original excitation control system cabinet structure is retained, and the entire system is upgraded by upgrading the board card.
Among them, the CoB main board, MUB measurement board, F10 input and output board, and LCP local control panel were replaced with the PEC800 controller,
CCM measurement control interface board, CIo comprehensive input and output board, and ECT excitation system control terminal in the Unitrol6800 system respectively.
For the upgrade of the power cabinet, since the power of the excitation system will not change during the transformation, the N-1 redundant configuration of the five
UNL3300 rectifier bridges in the original system has not been changed, but the control and measurement parts of the rectifier
bridge have been upgraded. And the fan circuit and power control part of the rectifier bridge have been upgraded. Among them, the signal interface board (PsI) was
changed to the rectifier bridge signal interface board (CsI), the circuit breaker of the rectifier bridge panel was changed from CDP to CCP, and the rectifier bridge control
interface board (CIN) was changed to the rectifier bridge control board (CCI).
For the upgrade of the demagnetization cabinet, the switch control part was mainly upgraded. By adding a CIo board to the switch cabinet and installing a special
power distributor and relay to control the demagnetization switch, the original PsI board was removed. Secondly, in the transformation of the current detection part,
the Hall element in the Unitrol5000 system was replaced by the current relay of the Unitrol6800 system.
For the upgrade of the excitation current measurement part, the rectifier side Hall element of the rectifier bridge was replaced with an AC side CT. Relying on the linearity of the
CT, the current sharing coefficient of the excitation system was increased to 0.98, so that the role of the rectifier bridge can be fully exerted in the system. .
For the upgrade of the fan power supply circuit of the rectifier cabinet, each power cabinet can independently control the power supply of the fans in the
cabinet to avoid the problem that if the power circuit relay fails in the original system, all the fans will not work.
3.3Unitrol6800 functional logic configuration points
The Unitrol6800 system adds PT slow-blow judgment logic, and defines the actions of PT slow-blow as alarm and channel switching. The system PT
slow-blow logic pressure difference is 2% to ensure sufficient sensitivity. Since some external reasons will cause the sequential increase or decrease of magnetic
commands, a special increase or decrease magnetic contact adhesion judgment logic has been added to effectively lock out external causes. At the same
time, it can
avoid the jitter of the relay on the increase or decrease magnetic circuit and ensure the stability of the circuit. The excitation temperature detection is used to
alarm in the system, but it cannot control the system tripping. The tripping intermediate relays K291 and K292 use high-power (≥5w) relays to avoid
the problem of tripping of the excitation system
due to signal interference.
4 Problems discovered during the transformation and their solutions
After upgrading the excitation system from Unitrol5000 to Unitrol6800, since the partition between the regulator cabinets of the original excitation switch
cabinet was removed and the mounting backplate of the regulator was moved forward, the hot air from the excitation switch cabinet will enter the excitation regulator
cabinet, causing the cabinet to be damaged. The internal temperature rises, and sometimes the temperature can even reach 45°C. In order to avoid problems caused
by high temperatures, partitions were added to reduce the temperature inside the switch cabinet and control the
temperature to 30°C.
During the maintenance process, if the grounding carbon brush of the generator is removed, it is easy to cause the rotor grounding relay isoLR275 to
malfunction. Therefore, during maintenance, the power supply of the grounding relay will be disconnected and the large shaft in the magnetic cabinet will be short-circuited.
5 Conclusion
Through the transformation of the excitation system, our company not only meets the needs of increasing the generator capacity, but also
eliminates the safety hazards of ARCnet failure or flat cable damage in the excitation system of the unit. It can find the fault point during maintenance
and prevent the unit from non-stop. event. The new board used in the new excitation system has modular characteristics, which can make online maintenance more
convenient, and because the boards use trigger pulse generation communication and optical fiber redundant communication, the stability of
information transmission is ensured. Avoid communication failures and damage to pulse lines.
https://www.xmamazon.com
https://www.xmamazon.com
https://www.plcdcs.com/
www.module-plc.com/
https://www.ymgk.com
330103-00-06-10-02-05CN Bently Nevada 3300 XL 8 mm Proximity Probes
AT-MX40FST-05 ALLIED TELESIS International Pty Ltd
ACN CS METSO high-performance multi-function
3500/40M 140734-01 Bently Nevada Proximitor Monitor I/O Module
70085-1010-411 13A AI-TEK Speed sensor
8602-FT-ST GE PAC8000 Field terminal, standard
ZETA6104 PARKER Indexer/Drive
1C31179G01 Westinghouse Remote Input Output Master Attachment Unit
VT-HNC100-1-23W-08-P-0 Rexroth VT-HNC100 Digital Axis Controllers
VRDM 39750 LWB Berger Lahr stepper motor
VFD4A8MS21ANSAA Delta Variable frequency Drive (VFD)
VE6041F01C1 EMERSON Smart Switch
UMI-7764 NI Universal Motion Interface
TVD1.3-15-03 Rexroth TVD Supply Modules
T2550L80F32ELINSERIAL FOXBORO unit controller
SH68-68-EP NI D-SUB Male
SDN20-24-100C SolaHD DIN guide power supply
PXI-8423 NI RS-485 Interface
PXI-7344 NI Stepper/Servo Motion Controller Module
PXI-6052E NI Multifunction DAQ Device
PXI-4472B NI PXI Sound and Vibration Module
PXI-2597 NI PXI RF Multiplexer Switch Module
PR6424003-030+CON021 EPRO eddy current displacement sensor
PR642310R-030-CN+CON021 EPRO Eddy Current Signal Converter
PPC-105T Advantech GX1 300 based Fanless Panel PC with 10″
PIB671-1500 ABB Advantage system metering board
PH266-01GK-C5 VEXTA 2-Phase Stepping Motor
PCS009 LAUER PCS 009 plus Operator Panel with MPI
PFXGP4501TADW display
PCI-6229 NI Multifunction I/O Device
PCI-6221 NI Multifunction I/O Device
P0912XX FOXBORO Transmitter actuator
P8 385RF-NG-SPT63-B HOERBIGER Solenoid valve
NPS-400AB B Fujitsu 470W Power Supply
NI-9227 NI C Series Current Input Module
MVME55006E-0161R Motorola VMEbus Single-Board Computer
MVME5500-0163 MOTOROLA VMEbus Single-Board Computer
MVIP302 Motorola IndustryPack Octal Serial Interface
MTR-3F-215 DEIF MULTI-TRANSDUCER W/ RS485 MODBUS
MTL5053 MTL POWER SUPPLY
MSK101D-0200-NN-M1-AG2-NNNN Rexroth MSK Synchronous Motors
MSK076C-0450-NN-M1-UG1-NNNN Rexroth MSK Synchronous Motors
MSK050C-0300-NN-M1-UG1-NNNN Rexroth MSK Synchronous Motors
MR-J2M-20DU Mitsubishi Melservo J2M Series
MRE-G128SP062FAC Nsd SENSOR,MULTI TURN
MN7234A2008 HONEYWELL DAMPER ACTUATOR 34NM 24V 0 TO 10
MKD090B-047-KG1-KN Rexroth MKD Synchronous Motors
ME203CN BACHMANN Processor Module
MKD071B-061-KP1-KN Rexroth MKD Synchronous Motors
MHD041B-144-PG1-UN Rexroth MHD Synchronous Motors
MKD071B-061-KG1-KN Rexroth servo motor
MCR-PSP-DC Phoenix Contact Alarm setting device
LSH-050-2-45-320T1.1R Lust LTi Drives
LS43.0124 EMG German sensor
LPQ172 Artesyn Embedded Technologies 4-output 175W open-frame AC/DC Power Supply
1X00416H01 EMERSON Process Management Power Supply
Reviews
There are no reviews yet.